background image

TROUBLESHOOTING

SYMPTOM

RECOMMENDED INTERVENTION

The amplifier doesn’t play, 
LED diodes aren’t lit, control 

light isn’t lit.

Check if the main fuse isn’t blown or if the power supply cord isn’t 
broken (use another). If it still doesn’t help, contact Laboga service 

personnel or any Laboga retailer.

There is smoke coming out of 

the amplifier.    

Immediately unplug the amplifier from the mains outlet  and 

contact authorized Laboga service personnel or any Laboga retailer. 
Don’t repair it yourself.

The amplifier doesn’t play, but 
LED diodes are lit.

Check if guitar cable is connected and if guitar cabinet works 
properly. Then, check if guitar’s volume potentiometer, Master or 

other potentiometers having influence on amplifier’s volume, aren’t 
mute.

If the above mentioned hints fail, unplug the amplifier from main 

outlet, wait at least 1 minute and check if anode fuse isn’t blown. If 
the fuse is blown, change it for a new one, turn the amplifier on 

again and observe the tubes  for any unusual signs. If, after you 
the change it, it blows again, contact authorized Laboga service or 

any Laboga retailer.

If the fuse wasn’t blown, put guitar cable to the Return socket at 
the back of the amplifier and check if you can hear the guitar:

If you do, check if any of preamp tubes aren’t broken by 
swapping them. If there is still no result, contact authorized 
Laboga service or any Laboga retailer.

If you can’t hear the guitar, contact authorized Laboga 
service or any Laboga retailer.

Clean channel works, but the 
distorted channel is mute.

Check if Lead Gain or Lead Volume isn’t mute. If not, unplug the 
amplifier from the mains electric supply, wait for the tubes to cool 

down, unscrew rear grate and change V2. If there are no results, 
contact authorized Laboga service or any Laboga retailer.

The amplifier makes hum 
even after turning 

Master 

down.

Check if the outer metal cover in any of the power tubes  is glowing 
red (it is usually grey). If yes, immediately turn the amplifier off 

and contact authorized Laboga service or any Laboga retailer. 

Page 16

Содержание Alligator AD 5200 Single

Страница 1: ...Hand made 50 watts Tube Guitar Amplifier Models AD 5200 Single AD 5200 Twin AD 5201 Single AD 5201 Twin AD 5202 Single AD 5202 Twin User s Manual...

Страница 2: ...icing top quality equipment Wide correction possibilities of the amplifier will enable each individual to find their own sound and will ensure long hours of creative entertainment We hope the amplifie...

Страница 3: ...THE SET 5 SAFETY PRECAUTIONS 6 TECHNICAL HINTS PROPER USAGE 7 FRONT PANEL 8 REAR PANEL 12 CHANGE OF TUBES IN THE AMPLIFIER 14 HOW TO USE THE AMPLIFIER IN ORDER TO PROLONG TUBE S LIFE SPAN 15 TECHNICAL...

Страница 4: ...ne quality is maintained This section is also equipped with a spring reverb The amplifier has two channels clean and distorted On the clean channel exists the possibility of obtaining a crunch sound a...

Страница 5: ...ame tone control for both channels sharing the switch for EQ Mod type Single footswitch changes channels and switches between Gain 1 and Gain 2 channel switching on relays separate Bright switches for...

Страница 6: ...ng loss To avoid electrical shock never open the amplifier s cover In case of failure refer servicing to qualified personnel Always use the highest quality signal cables we recommend Laboga cable Way...

Страница 7: ...er use solvents to clean use additional devices and accessories according to producer s recommendations during storms or when left unused for a long period of time power supply cord should be unplugge...

Страница 8: ...FRONT PANEL Single version Twin version Page 8...

Страница 9: ...the distorted channel HINT With a little value you can obtain crunch effect or overdrive By adding gain distortion is added until reading high gain For guitars with Humbucker pick ups and high output...

Страница 10: ...iddle frequency tone for the clean channel 16 Treble Adjusts the high frequency tone for the clean channel HINT Set all the potentiometers in a 12 00 o clock position then adjust them individually to...

Страница 11: ...HINT You should keep the switch in the up position if there are long breaks between playing You should also wait about 1 min between switching the Standby to the up position and turning the amplifier...

Страница 12: ...ON Before you change the fuse always unplug the amplifier from the power outlet and wait for at least one minute ATTENTION Always change the fuse for one of the same value 2 Additional footswitch sock...

Страница 13: ...cket brakes internal connection in the amplifier which bypasses the effects loop HINT This input can also be used as line input therefore the amplifier serves as a power amp 5 Effects loop socket Send...

Страница 14: ...be changed is worse sound of the amplifier The sound gets flat and the dynamics are worse There are certain signs that imply tubes should be changed red outer metal cover which is normally gray flash...

Страница 15: ...shorten tubes life span Use an original Laboga cover or hard case to prevent damage and dust TECHNICAL DATA INPUTS Guitar input sensitivity 10 dBV Maximum signal level 4 dBV Input impedance 1 M OUTPUT...

Страница 16: ...one turn the amplifier on again and observe the tubes for any unusual signs If after you the change it it blows again contact authorized Laboga service or any Laboga retailer If the fuse wasn t blown...

Страница 17: ...hange V1 for any other tube If the problem disappears keep such tube configuration If sounds don t fade turn the Lead Volume down and check if sounds disappear If yes unplug the amplifier from the mai...

Страница 18: ...WIRING AMPLIFIER TO SPAKER CABINETS Page 18...

Страница 19: ...Page 19...

Страница 20: ...ALL RIGHTS RESERVED 2009 LABOGA Page 20...

Отзывы: