Labnet FASTPETTE Скачать руководство пользователя страница 3

1

TABLE OF CONTENTS

1 - INTRODUCTION  .............................................................................................................. 2

2 - WORK SAFETY INSTRUCTIONS ..................................................................................... 2

3 - LIMITATIONS OF USE  ..................................................................................................... 2

4 - GETTING STARTED ......................................................................................................... 3

5 - ASPIRATING AND DISPENSING LIQUIDS  ...................................................................... 3

6 - TROUBLESHOOTING ...................................................................................................... 4

7 - REPLACING THE FILTER AND CLEANING THE VALVES ............................................... 5

8 - CHARGING THE BATTERY .............................................................................................. 6

9 - MAINTENANCE ................................................................................................................ 6

10 - COMPONENTS  ................................................................................................................ 7

11 - ORDERING INFORMATION  ............................................................................................. 7

12 - SPARE PARTS .................................................................................................................. 7

2

1 - INTRODUCTION

The 

FASTPETTE

pipette controller is designed for pipetting liquids with serological pipettes.

The device works with all types of glass and plastic serological pipettes in the range of 1 ml
to 100 ml.

The 

FASTPETTE

is equipped with replaceable membrane filters that protect against cross

contamination. The filters also prevent contamination of the mechanism by reagent vapors. 

The 

FASTPETTE

features a two speed control system which enables very fast dispensing

of large volumes and precise measuring of small volumes.

Fig.  1  shows  the  external  parts  of  the  pipette  controller  and  a  description  of  the  materials
used in the construction. 

2 - WORK SAFETY INSTRUCTIONS

Before operating the 

FASTPETTE

, all users should read these instructions carefully.

Using the pipette controller a manner inconsistent with the operating instructions may result
in damage to the device.

Any required repairs to the 

FASTPETTE

should be performed at an authorized service center.

Repair elsewhere may void the warranty.

• While using the 

FASTPETTE

, follow general laboratory safety guidelines. Protective clothing,

goggles and gloves should be worn.

• The 

FASTPETTE

shall be used for measuring liquids only in the manner specified in this

manual.  Liquids  to  be  measured  are  limited  by  the  chemical  and  mechanical  resistance 
of the device, as well as user safety.

• The pipette controller should not be used in environments where there is a risk of explosion.

• Information and instructions provided by the reagent manufacturer must be observed.

• Use only original spare parts and accessories.

• Only the original charger, supplied by the manufacturer, should be used for charging the

battery and powering the device.

• If  the  pipette  controller  malfunctions,  discontinue  use  immediately.  Clean  the  device  in

accordance with the operating instructions and contact the manufacturer for repair.

• Avoid excessive force while using the pipette controller.

3 - LIMITATIONS OF USE

• Substances that damage PP, SI, ABS, EPDM and POM should not be measured with the

FASTPETTE.

• The pipette controller shall not be used in environments where a risk of explosion is present.

• Flammable  liquids  shall  not  be  measured  –  in  particular  substances  with  a  flash-point

below 0 °C (ie ether, acetone).

• The pipette controller shall not be used for drawing acids with a concentration above 1 mol.

• The pipette controller shall not be used with substances with a temperature above 50°C.

• The ambient operating range of the pipette controller is +10 °C to +35 °C.

F

FA

AS

ST

T

P

PE

ET

TT

TE

E

Отзывы: