 1.0  Introduction

The Labnet Digital Incubators have been designed for general purpose incubations (<65°C), as well as those applications requiring 
higher temperatures (up to 65°C).

Temperature within the incubator is controlled and regulated by a microprocessor. Temperature is set and displayed digitally. An 
independent, user settable safety thermostat protects samples and the incubator from overheating in the unlikely event of a primary 
controller failure.

A fan, located in the chamber, assists in providing an exceptionally uniform environment. The fan also speeds temperature recovery 
after the door of the incubator has been opened. For applications where the flow of air in the chamber is undesirable, the fan may be 
switched off.

The interiors of the 311D and 611D incubators are constructed of stainless steel. The exteriors are made of cold rolled steel to resist 
corrosion and provide strength. The door of the incubator consists of two parts. The inner door is glass to allow for viewing the 
chamber contents without disrupting the temperature environment. The outer door is solid and insulated. It is also heated to help in 
maintaining the chamber temperature. The heated door prevents condensation from forming on the inner glass viewing door.

 2.0  Safety  Information

These units are high performance incubators for professional, industrial, or educational use where the preparation or testing of 
materials is done at approximately atmospheric pressure and no flammable, volatile, or combustible materials are being heated. 
These units are not intended for hazardous or household locations or use.

Your satisfaction and safety require a complete understanding of this unit. Read this instruction manual thoroughly before attempting 
to operate the incubator. All operators should be given adequate training before using this incubator.

NOTE:

 This equipment must be used only for its intended application. Any alterations or modifications of the incubator may void the 

warranty and may result in injury.

The electrical warning symbol indicates the presence of a potential hazard which could result in electrical shock. 

This symbol indicates a potential risk and alerts you to proceed with caution.

CAUTION: 

To avoid accidental bodily harming or burning be very careful touching the metal parts of the unit. It can be 

very hot after it is used at high temperatures. Allow the metal parts to cool down before handling.

 3.0  Specifications

Temperature range

Ambient, +5°C to 95°C

Temperature uniformity 
   I-5311-D 
   I-5611-D

 
±0.2°C at 37°C 
±0.25°C at 37°C

Temperature accuracy

±0.2°C

Temperature set/display

Digital

Temperature control

Microprocessor

Overtemperature safety

Independent, settable

Interior outlet

1 AMP

Door

Inner: glass 
Outer: solid, heated

Temperature uniformity 
   I-5311-D 
   I-5611-D

 
2.75 cu ft (77.9L) 
6.0 cu ft (169.9L)

Exterior construction

Cold rolled steel

Interior construction

Stainless steel

Exterior dimensions (D x W x H) 
   I-5311-D 
   I-5611-D

 
27 x 20 x 29 in. (68.6 x 51 x 73.7 cm) 
31 x 26 x 34 in. (78.5 x 66 x 86.4 cm)

Содержание 311D

Страница 1: ...Labnet 311D and 611D Digital Incubators Instruction Manual Catalog Numbers I 5311 D I 5611 D...

Страница 2: ...2 5 3 Lifting Handling 2 5 4 Leveling 3 5 5 Cleaning 3 6 0 Controls 3 7 0 Operation 3 7 1 Set Main Temperature Control 3 7 2 Calibration 3 7 3 Set Safety Thermostat 3 7 4 Fan Switch 4 8 0 Cleaning an...

Страница 3: ...g of materials is done at approximately atmospheric pressure and no flammable volatile or combustible materials are being heated These units are not intended for hazardous or household locations or us...

Страница 4: ...equipment If you have any questions about local requirements please contact the appropriate local agency Installation can be performed by the end user 5 1 Power Source Check the data plate for voltage...

Страница 5: ...at to its maximum position clockwise 7 1 Set Main Temperature Control Enter desired set point temperature To enter set point mode on the control press either the Up or Down button one time The digital...

Страница 6: ...too low see Section 7 3 Controller set too low see Section 7 1 Unit not recovered from door opening wait for display to stop changing Unit not recovered from power failure or being turned off incubat...

Страница 7: ...9 3 Other Code Description Solution Other 1 Controller on at all times locked up Turn unit off and on to reset If cannot change any condition on the front panel call Customer Service Other 2 Front pan...

Страница 8: ...ecause of a defect in material or workmanship contact Corning Customer Service at USA Canada 1 800 492 1110 outside the U S 1 978 442 2200 visit www corning com lifesciences or contact your local supp...

Страница 9: ...isting of US medical devices regulatory classifications or specific information on claims visit www corning com resources www labnetlink com For a listing of trademarks visit www corning com clstradem...

Отзывы: