|        LABNET 211DS SHAKING INCUBATOR

The Labnet 211DS Shaking Incubator is designed to be safe at least when operated under the following conditions:

 



Indoor use only

 



Altitude up to 2,000 meters

 



Pollution Degree 2

 4.0  Unpacking

Upon receipt of your Labnet 211DS Digital Shaking Incubator, examine the carton and unit for damages. If shipping damage has 
occurred, a claim must be filed with the carrier. The carrier is responsible for correcting shipping damages. Save all packaging until the 
unit has been shown to operate properly to your satisfaction. Carefully remove the unit from the carton and shipping pallet.

The package should include:

 



211DS Digital Shaking Incubator

 



2 large shelves

 



1 small shelf

 



12 shelf clips

 



4 leveling feet

 



Instruction manual

 



Power cord (both EU and UK cords in 230V models)

Complete and return the warranty card to register your new Labnet 211DS Digital Shaking Incubator.

 5.0  Installation

Local city, county, or other ordinances may govern the use of this equipment. If you have any questions about local requirements, 
please contact the appropriate local agency. Installation may be performed by the end user. 

5.1 Power Source

Check the data plate for voltage, cycle, phase and ampere requirements. If matched to your power source, plug the 
power cord into a grounded outlet. 

NOTE: 

Voltage should not vary more than 10% from the data plate rating. This unit is 

intended for 50/60 Hz application. A separate circuit is recommended to preclude loss of product due to overloading or 
circuit failure.

5.2 Location

In selecting a location, consider all conditions which might affect performance, such as heat from radiators, ovens, 
autoclaves, etc. Avoid direct sun, fast-moving air currents, heating/cooling ducts, and high-traffic areas. Allow a minimum 
of 5 cm between the unit and walls or partitions which might obstruct free air flow.

5.3 Lifting/Handling

This unit is heavy and care should be taken to use appropriate lifting devices that are sufficiently rated for these 
loads. Units should only be lifted from their bottom surfaces. Doors, handles and knobs are not adequate for lifting or 
stabilization. The unit should be completely restrained from tipping during lifting or transport. All moving parts, such 
as shelves and trays should be removed and doors need to be positively locked in the closed position during transfer to 
prevent shifting and damage.

5.4 Leveling

The unit must sit level and solidly. Leveling feet are to be installed in the holes at the base of the unit. Turn them 
clockwise to raise the level. If the unit must be moved, turn the leveling feet in all the way to prevent damage.

5.5 Cleaning

Be sure to disconnect the power cord before cleaning or decontaminating the unit.

The unit was cleaned at the factory, but not sterilized. Remove all interior parts, if assembled and clean the inside of the chamber 
thoroughly with a disinfectant that is appropriate to your application. Make sure to rinse the cleaned surface with a damp cloth, using 
water only, and dry the surface with a clean cloth. 

NOTE:

 Do not use chlorine-based bleaches or abrasives, as this will damage the 

stainless steel surfaces. A similar periodic cleaning is recommended.

Содержание 211DS

Страница 1: ...Labnet 211DS Digital Shaking Incubator Instruction Manual Catalog Numbers I 5211 DS I 5211 DS 220V...

Страница 2: ...0 Installation 2 5 1 Power Source 2 5 2 Location 2 5 3 Lifting Handling 2 5 4 Leveling 2 5 5 Cleaning 2 6 0 Controls 3 7 0 Operation 3 7 1 SmartCheck Temperature Control System 3 7 2 Calibration 3 7 3...

Страница 3: ...roughly before operating the incubator All operators should be given adequate training before using the 211DS Shaking Incubator NOTE This equipment must be used only for its intended application Any a...

Страница 4: ...rloading or circuit failure 5 2 Location In selecting a location consider all conditions which might affect performance such as heat from radiators ovens autoclaves etc Avoid direct sun fast moving ai...

Страница 5: ...de on the controller press either the Up or Down arrow pad one time The digital display will start to blink going from bright to dim While blinking the digital display is showing the set point To chan...

Страница 6: ...reaching the unit Check if the unit is plugged into the power supply Check if the circuit breaker has tripped Check if the Main Circuit Breaker has tripped Unit will not heat Verify the Main Control...

Страница 7: ...or contact your local support office Corning s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions Products rec...

Страница 8: ...isting of US medical devices regulatory classifications or specific information on claims visit www corning com resources www labnetlink com For a listing of trademarks visit www corning com clstradem...

Отзывы: