![Labkotec LCJ1-1 Скачать руководство пользователя страница 3](http://html2.mh-extra.com/html/labkotec/lcj1-1/lcj1-1_operating-instructions-manual_3179430003.webp)
OPERATING INSTRUCTIONS
(EN)
CABLE CONNECTORS LCJ1-1, LCJ1-2, LCJ1-3
2 / 7
DOC001645-ML2-1 | 14.8.2019
TECHNICAL DATA
LCJ1-1
LCJ1-2
LCJ1-3
Dimensions
Ø 30 x 145 mm
Ø 35 x 145 mm
Ø 35 x 145 mm
Weight
70 g
85 g
85 g
Temperature
Ambient temperature: -20 ... +60 °C, Storage temperature: -20 ... +60 °C
Protection
IP68
Ex-classification
Simple apparatus according to IEC/EN 60079-11 (Intrinsic Safety i)
II 1G Ex ia IIB T4 Ga
Ui = 30 V, Ii = 500 mA, Pi = 1 W, Ta = -20 °
C …+60
°C
Components (see Figures below)
(1)
Housing
ST 4000 ATEX, black, antistatic
(2)
Terminal blocks
2 pcs, 2-pole, core cross section
0,14-2,5 mm2
2 pcs, 3-pole, core cross section
0,14-2,5 mm2
2 pcs, 3-pole, core cross
section 0,14-2,5 mm2
(3)
O-rings (*)
2 pcs, 17 x 1,5 (NBR70)
2 pcs, 22 x 2,0 (NBR70)
2 pcs, 22 x 2,0 (NBR70)
(4)
Cable glands (*)
2 pcs, M20 x 1,5, PA, for cable
diameter 4-9 mm
2 pcs, M25 x 1,5, PA, for cable
diameter 5-13 mm
2 pcs, M25 x 1,5, PA, for cable
diameter 5-13 mm
(4.1)
Seal (*)
2 pcs, single-hole seal (CR)
1 pcs, single-hole seal (CR)
1 pcs, single-hole seal (CR)
(4.2)
Seal (*)
1 pcs, 2-hole seal
(2 x 5 mm holes, NBR70)
1 pcs, 3-hole seal
(3 x 5 mm holes, NBR70)
(5)
Unshielded sensor cable(s) (**)
(6)
Unshielded extension cable (**)
(*) O-rings and seals of cable glands are mineral oil resistant
(**) If shielded cable is used, shield must be cut and insulated properly
Figure 1. LCJ1-1 cable connector
Figure 2. LCJ1-2 cable connector
Figure 3. LCJ1-3 cable connector