Installation 

Mounting and ventilation 
Fix the unit to the wall, skirting board, mounting board o similar hard surface. A ventilation gap of at least 25mm 
should be left around the front and sides of the unit. 

Do not leave the power unit resting on a carpet. 
Do not install the power unit where it may become smothered with curtains or other fabrics. 
When installing the power unit in a roof space ensure that it will not become buried in thermal insulation 
materials. 

Signal connections are made to the coaxial sockets on the right-hand side of the power unit. Good quality coaxial 
cable to EN50117-2 must be used. Labgear recommend the use of CAI “benched marked” cable. 

 

The down lead from the masthead amplifier must be connected to the socket marked ‘IN’. 

 

The signal output from the socket marked ‘TV’ is connected to the receiving installation (satellite 
receiver, VCR, TV, etc.) or to the input of the cabled distribution system. 

Connections 
A connection to the PSM114V is made using Type-f (male) connectors. The use of high quality crimp connectors 
is preferred and the use of Labgear FPC100 is recommended. 

F type connectors should always be tightened with a spanner. Leaving them finger tight may result in unwanted 
signal ingress or leakage, as well as suck-outs in the frequency response. 
Mains power connections 
The PSM114V power unit is fitted with a fitted mains plug and may be plugged directly into a socket outlet. 
Alternatively the plug may be cut off and the power unit wired into a fused connection unit, fitted with an approved 
3A fuse to BS1362. The PSM114V is a class 2 construction and do not require a protective earth connection. If the 

power unit is not connected to the mains using the fused plug supplied or a fused connection unit, it must be 
protected by means of a fuse or MCB at the distribution board of rating no more than 6A. 
Short circuit protection 
The power supply is protected against output short-circuit by means of a PTC device. Should this protection 
operate, the power indicator LED colour will change from Green to Red to indicate a fault condition. To reset the 
protection, disconnect the unit from the mains and allow at least one minute for cooling before trying again. 

General Safety notes 

To avoid risk of electric shock during installation we recommend that the power unit and all associated TV 
receivers, etc. are isolated from the mains until the installation is complete. 
Fixed wiring for electrical supply to these products should be carried out in accordance with BS7671 (IEE Wiring 
Regulations). 
Distribution systems supplying signals to more than one household should comply with the safety requirements of 

BS EN50083-1. This requires the system to be earth bonded or the use of isolated outlets. 
 

General Safety Precautions 

The PSM114V are not waterproof and is intended for indoor use only and 

must

 

not 

be fixed where they could be 

exposed to dripping or splashing water. Objects containing liquids should not be placed on or near the 
appliances.  
To prevent the risk of fire, objects with naked flames (such as lighted candles) must not be placed on or near the 
appliances. 
Fitted Mains plug 
These appliances are supplied with the standard fused plug already fitted. If this is not suitable, refer to the 

instructions below. In the unlikely event that you need to change the fuse in the plug, a 3 Amp fuse to BS1362 
carrying the ASTA or BSI approval mark must be used. Always re-fit the plastic fuse carrier when replacing the 
fuse. 
Changing the Plug 
If the fitted mains plug is not suitable for the socket outlets in your home, it should be cut off and an appropriate 
new plug fitted. 

Wiring the new plug: Any instructions supplied with the new plug should be followed (these may state how 
much insulation to remove from the wires in the mains cord). The 

Brown 

wire must be fitted to the 

live (L)

 

terminal of the plug and the

 Blue 

wire to the

 neutral

 

(N)

 terminal. Neither wire should be connected to the

 earth 

(E) 

terminal of the 3-pin plug (this appliance does not require an earth connection). Ensure that the cord grip is 

the plug is a fused type; the fuse fitted should be rated at no more than 3 Amp. 

Caution: 

The old plug should be destroyed promptly since it could be dangerous if plugged into a live socket. 

PSM114V

 

2…12V variable 100mA power supply with Type-F connections 

Technical Data 

PSM114V 

 

Signal Connector type 

Type-F (female) 

IEC60169-24 

DC output 

2…12V 

Voltage tolerance 5% 

Short Circuit Protection 

Indefinite, with warning 

 

Signal frequency range 

44…862MHz 

 

Signal insertion loss 

0.5dB 

 

Power requirement 

230 V AC 50 Hz at <3W 

Fitted mains plug 

Power indicator 

Two colour LED 

Green-Red ( see text) 

Operating Temperature 

0…40ºC 

 

Dimensions 

65(H)x 80(W) x45 (D) mm 

Excludes connectors 

 

 