SET-UP AND USE

1. Make sure the Power Switch is in the center “OFF” position.

2. Set your Label Dispenser in place and plug the cord from the Power

Supply Module into the Power Input Jack on the rear of the Unit.

3. Connect the Power Supply Module to a suitable AC power source.

4. Place  your roll  of labels  on the Label Roll Holder  &  slide the Roll

Edge Guide(s) to the width of your label web. The Label Web can

be positioned from side to side as required to ensure that the label

lines up with the reflective Sensor.

5. Thread  the  label  web  between  the  Stripper  Bar  and  the  round

Guide  Rod  directly  above  it.  See  the  Label  Threading  Path

illustration.

6. Pull the label web UNDER the round Web Guide and slide the width

adjusters to the width of the web.

7. Loop  the  web  UNDER  the  Wire  Bail  on  the  Take-Up  Shaft  as

shown in the illustration.

8. Slightly  loosen  the  Label  Sensor  Lock  Knob,  until  you  can  just

rotate the Sensor. Point the sensor up so it is pointing at the bottom

of the Stripper Bar. Place the Power Switch in the “LOW” position.

Slowly  rotate  the  Sensor  down  until  the  label  begins  to  advance.

Continue to rotate the Sensor slowly until the desired label length is

protruding. Retighten the Lock Knob securely.

9. Use  the  “HIGH”  or  “LOW”  Switch  setting  to  select  the  desired

speed.

10.

IMPORTANT – Pull labels UP when removing them not to the

side.

11. If  excess  dust  or  dirt  accumulates  on  the  Label  Sensor  Eye  the

Dispenser  may  not  sense  labels  correctly.  Use  a  cloth  or  paper

towel  dampened  with  water  to  gently  clean  the  Label  Sensor.

Do

not use any chemicals on the sensor.

12. Optional  Flanges  for  the  inside  and  outside  of  the  label  roll  are

available.  These  Flanges  are  recommended  for  narrow  or  loosely

wound  labels  that  may  have  a  tendency  to  fall  off  the  roll.  Order

FLANGES-LD

. Set of two Flanges.

WARNING

This product is for indoor use only.

Not for use in wet locations.

Unplug unit before removing waste

material or performing any cleaning or

maintenance services.

Label Threading Path

OPTIONAL LABEL COUNTER:

The optional Label Counter will add

one count to the displayed number for each label that is dispensed. This

Option is available only factory installed in new Units.

When the Label Dispenser is first turned on, it may display a count of “1”

or the number from the previous count. You can reset the Label Counter

to zero (“0”) by pressing the

“R”

Reset Button.