background image

10

4.6) ET-DSEL SELECTOR USER PASSWORD MANAGEMENT

To prevent the door work program from being modified, it is possible to set a password that must be entered every time the selector 

ET-DSEL is used.

To enable the password, perform the operations listed below:

  1.  Press the SET button for 5 seconds to access the general programming menu (see Diagram 1 at para. 4.3.1)

  2.  Press the button F1 five times to go to the Password Management sub-menu.

  3.  Press the Enter button 

 to access the section “Password management”.

PASSWORD MANAGEMENT

PRIMARY PASSWORD (for the system owner-user)

It is a 5-character password used by the user to prevent unauthorized persons from having access to the selector ET-DSEL and change 

the work program.

Using a primary password is optional and must be enabled by the system owner.

The default technical password is “A-A-A-A-A”.

WARNING!

When enabling the password, be very careful not to forget the access combination.

SERVICE PASSWORD (for user)

It is a 5-character password that the system's owner may provide to persons authorized to use the selector ET-DSEL.

With the service password, it is only possible to change the work program of the automatic door.

The default service password is “A-A-A-A-A”.

To change the service password, it is necessary to log in using the primary password.

Use the button

 

 

to move the selection arrow downward, the F2 button to move back upward.

HOW TO CHANGE THE PRIMARY PASSWORD

• 

Select “PRIMARY PASSWORD”

• 

Press OK (F1).

• 

Enter the default primary password “A-A-A-A-A” pressing 5 times the button A.

(If the primary password is not the default password, since it had already been changed before, 

enter the currently-used primary password).

• 

Enter the new primary password, selecting a combination of 5 characters from the letters A-B-

C-D.

This section displays the two passwords available to the final user, the primary password and the 

service password.

The  technical  password  is  only  reserved  for  the  technical  staff  in  charge  of  installation  and 

maintenance operations.

• 

You are prompted to repeat the new password, so enter again the previous combination.

• 

If the password entered is correct, the message “PASSWORD OK” is displayed for one second, 

then the system returns to the PASSWORD MANAGEMENT section. Press the EXIT 

 button 

to return to the general programming menu

• 

If the password you entered does not match the previous one, the display shows PASSWORD 

ERROR, the system returns to the section PASSWORD MANAGEMENT and it is necessary to 

perform again the procedure.

Содержание NEXT 120s

Страница 1: ...USER MANUAL TRANSLATION OF THE ORIGINAL INSTRUCTIONS Automation for indoor automatic swing doors EN NEXT 75 NEXT 150 NEXT 120s NEXT 75 150 120S_EN_Rel 2 0_10 2020 CD0750EN MU ...

Страница 2: ...uced physical sensory or mental skills or by inexperienced people provided they are supervised or after the same have received instructions relating to the safe use of the equipment and to the understanding of the relevant hazards Children should not play with the equipment Cleaning and maintenance intended to be performed by the user must not be carried out by children without supervision Do not ...

Страница 3: ...M SELECTOR 6 4 2 MECHANICAL KEY SELECTOR EV MSEL 6 4 3 DIGITAL PROGRAM SELECTOR ET DSEL 7 4 4 DIGITAL PROGRAM SELECTOR T NFC 8 4 5 SELECTOR ET DSEL GENERAL PROGRAMMING MENU 9 4 6 ET DSEL SELECTOR USER PASSWORD MANAGEMENT 10 4 7 T NFC SELECTOR USER PASSWORD MANAGEMENT 12 4 8 LANGUAGE 13 5 OPERATION IN CASE OF POWER SUPPLY FAILURE 13 6 NOTIFICATION OF ERRORS AND OPERATIONAL ISSUES 14 7 MAINTENANCE 1...

Страница 4: ...0S POWER SUPPLY 115 230 50 60Hz POWER 40W 50W 50W DIMENSIONS OF THE AUTOMATION L x H x D 420 x 60 x 74mm 420 x 60 x 74mm 520 x 60 x 74mm FREQUENCY OF USE continuous OPERATING TEMPERATURE 15 C 50 C ELECTRIC MOTOR brushless 24Vdc POWER SUPPLY OF EXTERNAL ACCESSORIES 24 Vdc 1A STAND BY CONSUMPTION 5 W EQUIPMENT CLASS class II SOUND PRESSURE EMISSION LpA 70dB A 1 2 3 4 5 6 7 8 9 NOTE The grey part ind...

Страница 5: ...ort manual push If the closing safety sensor detects a presence the door immediately reopens and stays open as long as the sensor remains engaged If the opening safety sensor detects a presence the door stops and remains stationary for the entire period in which the sensor is engaged it will complete the opening cycle only after the sensor is released If during the opening motion the door collides...

Страница 6: ...input or using the remote control b Open door program The door remains motionless in the position of complete opening 4 2 MECHANICAL KEY SELECTOR EV MSEL OPERATING MODE Insert and turn the key of the selector EV MSEL to select the desired program Open door program The door remains motionless in the position of complete opening Manual free door Automatic operation is disabled and the door can be op...

Страница 7: ...ing press briefly the button the symbol on the display indicates that the function is on In a dual leaf door only the first leaf Master opens if the opening command is given from the internal or external radar inputs Partial opening only operates in bi directional unidirectional and open door automatic programs To disable partial opening press again briefly the button F2 It can have two distinct f...

Страница 8: ... program press the SET button once to exit the Screen Saver function and thus activate the selector the screen will increase its brightness now press SET again several times until you position on the desired work program If you have activated the program lock with the SLIDE function to exit the Screen Saver slide your finger from left to right on the buttons A SET B to activate the selector Warnin...

Страница 9: ...ord to prevent any unauthorised access to the digital selector ET DSEL DIAGRAM 1 SECTION RESERVED FOR TECHNICAL STAFF SECTION RESERVED FOR TECHNICAL STAFF SECTION RESERVED FOR TECHNICAL STAFF PASSWORD MANAGEMENT SECTION SECTION RESERVED FOR TECHNICAL STAFF SELECTOR OPTION SECTION NOT USED LANGUAGE SECTION The paragraphs below explain the procedure to be followed to manage the user password and to ...

Страница 10: ...m of the automatic door The default service password is A A A A A To change the service password it is necessary to log in using the primary password Use the button to move the selection arrow downward the F2 button to move back upward HOW TO CHANGE THE PRIMARY PASSWORD Select PRIMARY PASSWORD Press OK F1 Enter the default primary password A A A A A pressing 5 times the button A If the primary pas...

Страница 11: ... programming menu If the password you entered does not match the previous one the display shows PASSWORD ERROR the system returns to the section PASSWORD MANAGEMENT and it is necessary to perform again the procedure ENABLING USER PASSWORD USAGE primary and service password Select PASSWORD ON OFF Press OK F1 Press the ON button to enable the usage of user passwords and return to the menu PASSWORD M...

Страница 12: ...the only one that enables to enter the user password area and should therefore be known only by the owner of the store organization in which the door is installed The service password 2 instead is used for employees or third parties that can use it to change the work programs of the door but cannot in any way change or disable both passwords To change the password 1 press the button A after select...

Страница 13: ...SE OF POWER SUPPLY FAILURE In case of power supply failure the door can be opened and closed manually If the door is equipped with an electric lock use the special key to unlock it If the automation is not equipped with battery depending on the programming of the automation electronic control unit the door may operate as follows a The door can be opened by activating any opening command motion rad...

Страница 14: ...etting of the program selector The door stops during its motion and inverts the running direction The door detects an obstacle along its motion Identify the obstacle and remove it The door experiences friction along its motion Adjust the door for this operation please contact the service centre The electronic control unit beeps multiple times and door operation is irregular The defect depends on t...

Страница 15: ...about the expiry of the maintenance interval when the message SCHEDULED MAINTENANCE is displayed Each maintenance operation is recorded into the maintenance log The final user must limit himself to cleaning the glass surfaces the fixture profiles and if necessary the motion and presence sensors taking care to lock the door while performing these operations 8 DISPOSAL At the end of its lifecycle th...

Страница 16: ...NEXT Made in Italy by S p A Via Ilariuzzi 17 A S Pancrazio P se 43126 PARMA ITALIA Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com LABEL service centre ...

Отзывы: