background image

 
 
 

Содержание i-FeedGoodL LABCH500IP

Страница 1: ...i FeedGoodL Cellular Modem LABCH500IP Technical Guide ...

Страница 2: ......

Страница 3: ... 2 Mechanical installation 4 Positioning of the connection cables 5 Positioning the antenna 6 Connections 7 How to connect the modem to i FeedGood L 7 Installing the SIM card 8 How to remove the SIM card 8 EC Declaration of Conformity 9 2 Description 10 Descriptions of LEDs 11 3 Annex A 12 Technical Specifications 12 ...

Страница 4: ...ur Distributor or send a support request to the address support labelgroup com Important safety standards Carefully read all the documentation attached to the modem Comply with all the instructions and precautions contained in this Guide Only qualified personnel are authorised to assemble and commission this equipment Do not expose the modem into contact with aggressive chemicals or solvents that ...

Страница 5: ...ondensation If the modem case is damaged or broken If the vehicle battery needs to be recharged This symbol indicates that based on local laws and standards the product must be disposed of separately from household waste When the product can no longer be used it must be brought to the collection spot established by local authorities Check local standards for further information regarding waste of ...

Страница 6: ...able and vibration free surface It is recommended to follow the following guidelines Do not install or place the modem near heat sources or strong magnetic fields motors magnets etc Install the modem at least 1m from an electronic device Personal Computer Cell Phone etc in order not to reduce the effective range ...

Страница 7: ...the connection cables are correctly connected and positioned Improper positioning of the cables can significantly reduce the performance of the modem It is recommended to follow the following guidelines Fasten the cables securely to the modem Keep the cables away from the antenna Do not roll up or tangle the cables Do not use cables longer than 5m ...

Страница 8: ... connecting different types of antennas Normally a high performance antenna is provided with the modem which may be easily installed on a wall by using the supplied bracket The antenna is omnidirectional and to assure optimal reception must be installed facing the sky on a flat clean vibration free surface as high as possible from the ground ...

Страница 9: ...hrough a cable with two straight M12 connectors M F 8 pole The female connector must be inserted into the J1 connector of the modem while the male connector must be inserted into the COM A connector of the scale J1 Connector LABCH500IP Modem Pin Function 1 VIN 2 CTS 3 DTR 4 TxD 5 GND 6 RxD 7 n c 8 n c Legend 1 i FeedGood L 2 LABCH500IP Modem 3 Antenna ...

Страница 10: ...as follows 1 Open the case 2 Find the slot where to enter the SIM card on the side of the modem The side of the modem is highlighted with the SIM writing 3 Make the SIM card slide in the slot with the contacts side facing down and the cut facing the inside of the modem as shown in the figure below 4 Enter the SIM card until it locks 5 Re close the case How to remove the SIM card To remove the SIM ...

Страница 11: ...e with the instructions provided in this Guide it could be faulty or cause the surrounding equipment to malfunction In any case there is no guarantee of these failures not occurring in a specific installation Should any malfunctioning occur contact the Customer Service which can suggest measures to be taken to eliminate the problems Compliance with Directives is only guaranteed when original acces...

Страница 12: ...b in the following way i FeedGood L COM A Port Modem Modem Type for Data Transfer LABCH500 modem Modem Parameters APN sets the APN mobile operator of the SIM card User sets the name displayed in FarmManagerWeb in the FMW Cloud User field Settings Farms Password sets the Password displayed in FarmManagerWeb in the FMW Cloud Password field Settings Farms FMW Cloud sets N EUROPE if you have activated...

Страница 13: ...ng Power Indicates presence of DC power when lit TR Not used CD Indicates established cellular data connection when lit LS Indicates the status of the cellular connection Off no connection to the cellular network Continuously lit SIM card is not installed or no signal is present Slow blink powered and searching for a connection or connected Signal Indicates the Quality of the cellular signal ...

Страница 14: ...cifications Radio Technology HSPA Frequency Band MHz 850 900 1700 1900 2100 Interface RS232 Power Supply Voltage 7 32Vdc Power Consumption Max 10W Operating Temperature 30 C 70 C Case ABS V0 Degree of Protection EN60529 IP66 Weight 800g Dimensions L x W x H 160x130x60mm 3 ...

Страница 15: ...e or suspension from using the products nor will we be held liable for damage which our products can cause in relation to their use or damage resulting from failure to use the products during the repair phase even if covered by Warranty For further information on Terms and Conditions of the Warranty contact Customer Service Label reserves the right to make changes and improvements to the products ...

Страница 16: ...Label S r l Via Don Mazzucotelli 6 A 24020 Gorle BG ITALY Phone 39 035 30 28 12 Fax 39 035 30 28 15 support labelgroup com www labelgroup com ...