Architect’s and Engineer’s Specifications

NLB 60E NomadLink Bridge & System Controller

Overview and Functions

The network bridge and system controller shall provide an interface 
between multiple power amplifiers equipped with NomadLink moni-
toring/control facilities and a host computer running associated De-
viceControl software. Communication between the network bridge 
and system controller and the host computer shall be over an Ethernet 
LAN using TCP/IP protocols. The IP address for the network bridge 
and system controller and system controller shall be entered manu-
ally from the front-panel or set remotely by a DHCP server. Commu-
nication between the network bridge and system controller and the 
power amplifiers shall be over a daisy-chained subnet with intercon-
nections  on  Cat-5  cable  using  RJ45  connectors.  The  subnet  shall  
accommodate as many as 60 amplifiers and as many as 480 ampli-
fier channels. The distance between the network bridge and system 
controller and any amplifier, or between any two amplifiers, shall be 
up  to  300  m  (980  ft.)  and  total  length  of  the  subnet  cabling  shall 
be up to 700 m (2300 ft.) when the network forms a closed loop. 
When the network is an open daisy-chain, total length shall be up 
to 400 m (1300 ft). The network bridge and system controller shall 
be able to detect a closed loop network, and report an error if the 
loop is broken. The network bridge and system controller shall pro-
vide  phantom  power  through  the  network,  thereby  maintaining  a 
network  connection  when  amplifiers  are  powered  off  or  malfunc-
tioning. Mute on/off function for all channels in the subnet shall be 
accessible on front-panel buttons. General faults as well as individual  
amplifier  faults  shall  be  indicated  with  a  red  Fault  LED  on  the 
front-panel  and  on  the  character  display.  The  network  bridge  and 
system  controller  shall  offer  three  general  purpose  input  (GPI) 
connections  for  external  control  purposes;  one  GPI  shall  sense  
voltage (above or below +10 VDC) while two GPIs shall sense con-
tact  closure.  GPI’s  shall  be  user  configurable  to  operate  amplifier 
subnet power on/off and mute channels.

Connectors, Controls, and Indicators

The  following  connectors  shall  be  provided  on  the  rear-panel:  one 
EtherCon  RJ45  for  Ethernet;  two  EtherCon  RJ45  for  loop  subnet 
(NomadLink) In and Out; one 2-pole Phoenix input for voltage sens-
ing GPI; and two 2-pole Phoenix inputs for contact-closure GPI. The 
following connector shall be provided on the front-panel: one stan-
dard RJ45 Ethernet in parallel with the rear-panel Ethernet connec-
tion.

The following controls shall be provided on the front-panel: six navi-
gation and parameter selection keys, and two momentary switches 
to activate global power on or off for all power amplifiers connected 
to the subnet. 

The  following  LED  indicators  shall  be  provided  on  the  front-panel: 
front-panel  operation  locked  (yellow),  fault  warning  (red),  ampli-
fier subnet muted (red); NomadLink (subnet) connected and active 
(blue);  Ethernet  connected  (orange),  and  Ethernet  active  (yellow). 
A 2x16 character display with white text on blue background shall  
display network status and parameters.

Power Supply

The  network  bridge  and  system  controller  shall  have  a  universal 
power supply with automatic selection of AC line sources from 100 
V to 240 V at 50 Hz or 60 Hz. Power consumption shall be less than 
20 watts.

Physical

The network bridge and system controller shall be 483 mm (19 in.) 
wide, 44 mm (1.75” or 1 U) high, and 208 mm (8.2 in.) deep. Weight 
shall be 2.25 kg (5 lbs.). Housing shall be plated and painted steel 
with an anodized aluminum front-panel. 

The network bridge and system controller shall be approved for use 
as specified by CE and CSA. The network bridge and system control-
ler shall be the Lab.gruppen NomadLink Bridge & System Controller 
NLB 60E. 