14. LUCIA application browser 

12    

LUCIA Operation Manual  rev 1.0.0 

13.3. Protection mode 

The amplifi er enters Protection mode when thermal conditions or current draw exceed safe limits. When the 
amplifi er cools below the thermal threshold, or nominal load conditions are restored, the amplifi er exits Protection 
mode automatically. 

IMPORTANT – Protection mode often results from excessive operating levels, improper load conditions or 
insuffi cient ventilation. Always check these conditions any time a LUCIA amplifi er enters Protection mode.

14. LUCIA application browser 

14.1. Introduction 

The LUCIA Application Browser is a simple, intuitive software editor for confi guring the signal matrixing and DSP 
features of LUCIA matrix models (LUCIA 120/M and 240/M). Amplifi er functions are quickly programmed offl ine 
and then downloaded to the individual LUCIA units via the USB port. 

 

 

Note: Transfer of preset data is a one way process. Presets can only be downloaded to the LUCIA 

 

device; you cannot upload settings back to the Application Browser. Therefore, if you want to 

 

connect to a device at a later time and make changes, it is important to save the settings in the 

 

computer running the application browser when you program the LUCIA. This way they can be 

 

recalled, edited and downloaded to the LUCIA device at a later time. 

 

Factory presets for common applications include input and matrix settings plus output equalization 

 

pre-optimized for compatible Tannoy loudspeakers and generic loudspeaker types. All parameters 

 

are user adjustable, allowing creation of custom user presets that may be stored for future use. An 

 

online “sync mode” allows real-time setting of parameters – a useful feature for adjusting loudspeaker

 

response for room acoustics using the four-band parametric equalizers.

14.2. Software download and installation 

The LUCIA Application Browser software is available for free download from the Support section of the 
Lab.gruppen web site. Select Software & Firmware from the left-hand menu. You must be registered to access
the download pages.

Under LUCIA, select LUCIA Application Browser. Follow the on-screen instructions. Note that there is no separate 
installation wizard. When downloading the compressed (zipped) fi le, simply save to any convenient location 
(desktop, documents) where write privileges are available.

Содержание LUCIA Series

Страница 1: ...LUCIA Compactinstallationamplifiers Operation Manual...

Страница 2: ...such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been...

Страница 3: ...producing hazardous output voltages To avoid electrical shock do not touch any exposed speaker wiring while the amplifier is operating External wiring connected to the speaker terminals shall be inst...

Страница 4: ...ome 6 5 2 Features all LUCIA models 6 5 3 Additional features on LUCIA 120 2M and 240 2M only 6 6 Unpacking and visual checks 7 7 Installation 7 7 1 Wall mounting 7 7 2 Rack shelf mounting 7 7 3 Lab g...

Страница 5: ...ut block 15 14 5 2 2 Matrix block 15 14 5 2 3 Output block 16 14 5 2 4 Control block 17 14 6 Saving and storing custom applications 18 14 6 1 Saving applications 18 14 6 2 Storing and sharing applicat...

Страница 6: ...e protects the amplifier and connected loudspeakers from potential damage caused by clipping thermal overload or extreme low line voltage 5 2 Features allLUCIAmodels Maximum output power across range...

Страница 7: ...ting is evaluated for North America according to UL CA60065 For mounting on surfaces other than drywall please ensure that the method of mounting is suitable for the wall material Also be certain that...

Страница 8: ...able interpretation In a typical application if a loudspeaker has a sensitivity of 87 dB SPL at 1 m for 1 W then the fan will stay silent for SPL levels up to 95 dB 87 7 8 at 1 m distance from the lou...

Страница 9: ...olor LED illuminates to provide channel status information as follows Green Signal is present at the input and the channel is operating normally Amber Limiting is active on the channel Limiting is eng...

Страница 10: ...up to 4 mm2 12 AWG can be accommodated Observe polarity to avoid low frequency cancellation loss Note Bridge mode connection is not supported 4 GPIO Remote connector Connect external control and stat...

Страница 11: ...of output volume output 1 on GPI1 and output 2 on GPI2 Please note that this control is in series with the control on the front panel There are two ways to do this A Connect a GPO from an external con...

Страница 12: ...e computer running the application browser when you program the LUCIA This way they can be recalled edited and downloaded to the LUCIA device at a later time Factory presets for common applications in...

Страница 13: ...olumn displays the various options and tools available for configuring the device Four icons are displayed in a block diagram format Inputs Matrix Outputs and Control When an icon is selected the appl...

Страница 14: ...ck the at the bottom of the column to add another device to the application Note that saving multiple units as one Application is for user convenience only parameters for each device must be downloade...

Страница 15: ...ny or all of the four outputs the two loudspeaker outputs of the amplifier or the two auxiliary line outputs The level for each output is adjustable from 0 to 30 dB using the fader to the right of the...

Страница 16: ...dB per octave high pass Butterworth filter Low Cut 6 first order 6 dB per octave high pass Butterworth filter Low Shelve 12 Shelving boost or cut with 12 dB per octave slope Low Shelve 9 Shelving boo...

Страница 17: ...rol Block allows the user to define functions for each of the two GPI ports of the device by selecting a function from the MODE menu The functions available for each port are Output Level Source Selec...

Страница 18: ...le IMPORTANT Do not close the main Application Browser window quit the program before saving an Application file The window will close immediately with no prompt and all entered information will be lo...

Страница 19: ...ircular animation shows in the selected device while updating is in progress Online Mode is particularly helpful for adjusting output equalization while listening to or measuring the connected loudspe...

Страница 20: ...omponents The default function for GPI is level control a linear potentiometer with a value between 1 k to 100 k ohm can be used As the GPI is internally pulled high it will default to full level if n...

Страница 21: ...it is as illustrated below this is also how the Lab gruppen accessory is made The May 2014 release of the Application Browser software allows customization of selections and voltages for each of the s...

Страница 22: ...ere is what is known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation LUCIA120 2M Level Load Output power Mains voltage Line current Wa...

Страница 23: ...s known as the Active Power in the amplifier providing useful real world values of power consumption and heat dissipation LUCIA240 2M Level Load Output power Mains voltage Line current Watt 1 Thermal...

Страница 24: ...n detachable screw terminals GPI power control input 3 2 channels of voltage sense type 4 pins in a detachable screw terminal Default for gain GPO power state output 3 Contact closure type 2 pins in a...

Страница 25: ...ough a LUCIA is 9 15 ms acoustically equivalent of 10 ft or 3 m This is primarily due to the look ahead limiters and to the multiband mastering compression used in our ADLC algorithm which adjusts for...

Страница 26: ...M and Auto Load SenseTM are trademarks of Lab gruppen AB All other trademarks remain the property of their respective owners Copyright 2014 Lab gruppen AB All rights reserved labgruppen com Item no OM...