15.  Do not run the output of any amplifier back into another channel's input. 
16.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has 

been damaged in any way such as: 

• 

Power-supply cord or plug is damaged 

• 

Liquid has been spilled into the unit 

• 

An object has fallen into the unit 

• 

The unit has been exposed to rain or moisture 

• 

The unit does not operate normally 

• 

The unit was dropped or the enclosure is damaged 

17.  Do not remove top or bottom covers. Removal of the cover will expose hazardous voltages. 

There are no serviceable parts inside and removal may void the warranty. 

18.  An experienced user shall always supervise this professional audio equipment, especially if 

inexperienced adults or minors are using the equipment. 

PKR= rëÉê=êÉëéçåëáÄáäáíó=

PKRKN= péÉ~âÉê=Ç~ã~ÖÉ=

!

Your amplifier is very powerful and can be potentially dangerous to both, loudspeakers and 
humans alike. Many loudspeakers can be easily damaged or destroyed by overpowering, 
especially with the high power available from a bridged amplifier. Always check the speakers’ 

continuous and peak power capabilities.  
Even if the amplifier’s front panel attenuators can be used to reduce the gain, it is still possible to reach 
full output power if the input signal level is high enough. 

PKRKO= péÉ~âÉê=çìíéìí=Ü~ò~êÇ=

Power amplifiers are capable of producing hazardous output voltages. To avoid electrical s
do not touch any exposed speaker wiring while the amplifier is operating. See page 

12

hock, 

 about 

outputs for proper connection of speakers.  

PKRKP= o~Çáç=áåíÉêÑÉêÉåÅÉ=

A sample of this product has been tested and complies with the limits for the European Electro 
Magnetic Compatibility (EMC) directive.  These limits are designed to provide reasonable protection 
against harmful interference from electrical equipment. This product uses radio frequency energy and if 
not used or installed in accordance with these operating instructions, may cause interference to other 
equipment, such as radio receivers. However, there is no guarantee that interference will not occur in a 
particular installation. 
If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment on and off, the user is encouraged to try to correct the interference 
by one or more of the following measures: 

• 

Reorient or relocate the antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

• 

Check if the affected unit complies with the EMC limits for immunity, (CE-labelled). If not, 
address the problem with the manufacturer or supplier. All electrical products sold in the 
EC must be approved for immunity against electromagnetic fields, high voltage flashes, and 
radio interference. 

• 

Consult the dealer or an experienced radio/TV technician for help. 

 
 
 
 
 

i~ÄKÖêìééÉå== =

=

=

=

=

========================

P

 

rëÉê=j~åì~ä===ám=VMM====sÉêëáçå=MKP======OMMPJMOJOR=

Содержание iP 900

Страница 1: ...m VMM rpbo j kr i...

Страница 2: ...7 5 3 4 Bridge mono mode 7 5 3 5 Bridge mono mode features 8 6 INSTALLATION 8 6 1 Mounting 8 6 2 Cooling 8 6 3 Operating voltage 8 6 4 Grounding 9 6 5 Power consumption 9 6 5 1 Calculation 10 7 CONNEC...

Страница 3: ...the amplifier while wet or standing in liquid 5 Clean only with dry cloth 6 Do not block the air intake or exhaust ports Install the unit in accordance with the instructions 7 Do not operate the ampli...

Страница 4: ...es To avoid electrical s do not touch any exposed speaker wiring while the amplifier is operating See page 12 hock about outputs for proper connection of speakers PKRKP o A sample of this product has...

Страница 5: ...ator This indicator illuminates if the amplifier tries to operate above its maximum operating temperature 90 C The indicator first comes on as a warning to either turn down the input level or check th...

Страница 6: ...or off switch OUT position See page 13 4 Input signal XLR Neutrik Combojack features also TRS phone jacks Pin 2 is hot see page 10 5 Link Output 3 pole screw terminal of Phoenix brand Connected in par...

Страница 7: ...B to 41dB in 3dB steps See the different settings for the DIP switches in the table below The three switches to the very left are for channel B and the three to the very right are for channel A RKNKO...

Страница 8: ...illoscope probes if you are bench testing Reverse operation of Channel B RKPKP q In tandem mode both channels inputs are linked and receive the same signal The tandem mode is active if the Link switch...

Страница 9: ...Your amplifier uses a forced air cooling system to maintain a low and even operating temperature All fan cooled Lab gruppen amplifiers have front to rear airflow There are several reasons for this one...

Страница 10: ...d interference SKR m There are three ways to determine the power current consumption of the amplifier First the peak current draw at full output power Under this condition the power will blow the main...

Страница 11: ...ast 5dB 1 3 of full power and a producing 320 watts per channel The 1 3 power per channel is accordingly 320 3 106 5 watts and total output 2 x 106 5 213 watts The power consumption according power co...

Страница 12: ...d signals are less sensitive to AC hum and radio interference The source impedance should be less than 1 kohms to avoid high frequency loss in long cables T connector labeled Link provided on each cha...

Страница 13: ...co al to ground or t terminals Pay attention to speaker polarity loudspeakers connected out of polarity degrade quality and may be damaged as a consequence Keep the speaker cable leads as short as pos...

Страница 14: ...cate that the output circuits are receiving the correct rail voltage V molqb qflk cb qrobp Each Lab gruppen amplifier has many advanced protection features protecting both the amplifier and the speake...

Страница 15: ...full output power the VHF protection mutes the input signal This is indicated on the front panel 2 labeled Protect After five seconds the outputs will un mute and return to normal operation unless the...

Страница 16: ...rotection is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing cau...

Страница 17: ...NN pmb fcf qflkp i K NS r j m VMM s MKP OMMPJMOJOR...

Страница 18: ...sibility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurre...

Отзывы: