R= ob^o=m^kbi=cb^qrobp=

Before turning the amplifier on please read the following sections to make sure that the unit is set up 
properly for your specific application. 

RKNKN= d~áå=

The gain of the fP 2400 is fixed to 32 dB 

RKNKO= pÉåëáíáîáíó=

Sensitivity is defined as how many volts (rms) or dBu (referred to 0.775Vrms) are required to get full 
output power. As the output power varies with the load impedance, usually 4 ohms is the reference. But 
in the case of an MLS-switch equipped amplifier there are many choices for full output level in different 
load impedances.  

Sensitivity in Vrms 

fP 2400Q 

  

MLS SWITCH SETTING 

LOAD 

CONFIGURATION 

-3 dB 

0 dB 

 

 

  

  

16 ohms 

Quad (4 channel) 

0,98 

1,42 

 

 

  

  

8 ohms 

Quad (4 channel) 

1,00 

1,37 

 

 

  

  

4 ohms 

Quad (4 channel) 

0,98 

1,33 

 

 

  

  

2 ohms 

Quad (4 channel) 

0,91 

  

 

 

  

  

 

 

  

  

16 ohms 

Stereo (2 channels bridged) 

0,98 

1,37 

 

 

  

  

8 ohms 

Stereo (2 channels bridged) 

0,98 

1,33 

 

 

  

  

4 ohms 

Stereo (2 channels bridged) 

0,90 

  

 

 

  

  

 
Sensitivity in dBu 

fP 2400Q 

  

MLS SWITCH SETTING 

LOAD 

CONFIGURATION 

-3 dB 

0 dB 

 

 

  

  

16 ohms 

Quad (4 channel) 

2,0 

5,3 

 

 

  

  

8 ohms 

Quad (4 channel) 

2,3 

4,9 

 

 

  

  

4 ohms 

Quad (4 channel) 

2,0 

4,7 

 

 

  

  

2 ohms 

Quad (4 channel) 

1,4 

  

 

 

  

  

 

 

  

  

16 ohms 

Stereo (2 channels bridged) 

2,1 

4,9 

 

 

  

  

8 ohms 

Stereo (2 channels bridged) 

2,1 

4,7 

 

 

  

  

4 ohms 

Stereo (2 channels bridged) 

1,3 

  

 

 

  

  

 

i~ÄKÖêìééÉå== =

=

=

=

======================

========================

S

 

rëÉê=j~åì~ä===Ñm=OQMM=n=====sÉêëáçå=MKU========OMMPJNMJMT=

Содержание fP Series FP 2400Q

Страница 1: ...m OQMMn rpbo j kr i...

Страница 2: ...ing MLS switch 9 5 4 1 A practical way to find your MLSTM settings 9 5 4 2 MLS technology the background 10 5 4 3 The problem 10 5 4 4 The solution 10 6 INSTALLATION 10 6 1 Mounting 10 6 2 Cooling 10...

Страница 3: ...isk of fire or electric shock do not expose this apparatus to rain or moisture PKP rqflk To reduce the risk of fire or electric shock do not remove screws No user serviceable parts inside Refer servic...

Страница 4: ...ery powerful and can be potentially dangerous to both loudspeakers and humans alike Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a...

Страница 5: ...ys use the original packing QKO c m Figure 1 front panel 1 Carry protection handle Both handles can be used to carry the amplifier they also act as protection for the front panel In permanent installa...

Страница 6: ...ns mains power on or off See page 11 and 14 QKP o m Figure 2 Rear Panel 1 Output Speaker connector The Speakon connector from Neutrik may be unfamiliar to some users A full description can be found in...

Страница 7: ...level in different load impedances Sensitivity in Vrms fP 2400Q MLS SWITCH SETTING LOAD CONFIGURATION 3 dB 0 dB 16 ohms Quad 4 channel 0 98 1 42 8 ohms Quad 4 channel 1 00 1 37 4 ohms Quad 4 channel 0...

Страница 8: ...are connected in normal polarity mode By having channel A and B and C and D operating in opposite polarity the energy storage in the power supply is more efficient This is significant for signals bel...

Страница 9: ...results in twice the voltage swing four times the peak power and just less than three times the full power of a single channel One way to understand the load and power from the amplifier s perspective...

Страница 10: ...ion for your application There is no risk to damage the amplifier since it is very well protected even down to 0 3 ohms If uncertain or where time does not allow just stick to the default positions Th...

Страница 11: ...adjusted for a much higher current so it cannot interfere with the requirements by the loudspeaker impedance curve S fkpq ii qflk SKN j The amplifier is two rack units high 2U and will fit into a sta...

Страница 12: ...a short circuit is introduced between the two thereby enabling electrical protection If a unit in the system is faulty its mains fuse will blow due to this automatic ground system If however you wish...

Страница 13: ...175 MLS at 3dB note 1 Average power with music as program source The amplifier driven to clip level note 2 Normal music power with 9dB headroom IEC standard power rating MAINS INPUT POWER MAX OUTPUT...

Страница 14: ...ms to avoid high frequency loss in lo cables TRS p g If you leave a pin di A better method for using unbalanced sources is shown in Figure 8 This is similar to the connection for balanced lines but pi...

Страница 15: ...that the AC mains voltage is correct and the same as the one printed on the rear panel of the amplifier See pages 10 about operating voltage and power consumption Make sure that the switches on the r...

Страница 16: ...utput and comparing the distortion produced between the input and output of the amplifier If the distortion exceeds 1 THD for any reason voltage or current clipping the limiter reduces the input signa...

Страница 17: ...VKNKR If the AC mains voltage is lower or higher than the allowed operational voltage over or under voltage the power supply will automatically shut down Once the mains voltage is above the minimum s...

Страница 18: ...ion is not activated If it is remove possible high frequency oscillations from the relevant input Fault The amplifier goes into thermal protection when driven at low level Check that nothing causes a...

Страница 19: ...NN pmb fcf qflkp i K NU r j m OQMM n s MKU OMMPJNMJMT...

Страница 20: ...bility for any loss due to cancellation of any events or rent of replacement equipment or costs due to third party s or customer s loss of profit or any other indirect cost or losses however incurred...

Отзывы: