28
C Series
Quick Start Guide
29
C 28:4
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via NomadLink
0
0
0
0
0
Powered on, idling.
123
0
123
420
106
Amp (I)
Watt
Pink noise
(1/8 rated power)
8 Ω / Ch.
700 x 4
11.6
5.8
727
350
377
1286
324
16 Ω / Bridged
1400 x 2
4 Ω / Ch.
700 x 4
13.0
6.5
775
350
425
1450
365
8 Ω / Bridged
1400 x 2
2 Ω / Ch.
300 x 4
9.4
4.7
529
150
379
1293
326
4 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
10.4
5.2
663
350
313
1068
269
200 V / Bridged
1400 x 2
Pink noise
(1/4 rated power)
*3)
8 Ω / Ch.
700 x 4
24.0
12.0
1589
933
656
2237
564
16 Ω / Bridged
1400 x 2
4 Ω / Ch.
700 x 4
20.8
10.4
1359
700
659
2249
567
8 Ω / Bridged
1400 x 2
4 Ω / Ch.
300 x 4
14.0
7.0
843
300
543
1853
467
8 Ω / Bridged
600 x 2
100 V / Ch.
700 x 4
21.4
10.7
1458
933
525
1790
451
200 V / Bridged
1400 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
20 A / 5-20P
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here is what
is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.
C 16:4
Level
Load
Rated power
Line Current *2)
Watt *1)
Thermal Dissipation
115 VAC
230 VAC
In
Out
Dissipated
BTU/hr
kCal/hr
Standby with remote power off via NomadLink
0
0
0
0
0
Powered on, idling.
129
0
129
440
111
Amp (I)
Watt
Pink noise
(1/8 rated power)
8 Ω / Ch.
400 x 4
8.6
4.3
526
200
326
1112
280
16 Ω / Bridged
800 x 2
4 Ω / Ch.
300 x 4
8.2
4.1
485
150
335
1143
288
8 Ω / Bridged
600 x 2
2 Ω / Ch.
n.r.
4 Ω / Bridged
n.r.
100 V / Ch.
400 x 4
7.6
3.8
463
200
263
897
226
200 V / Bridged
800 x 2
Pink noise
(1/4 rated power)
*3)
8 Ω / Ch.
400 x 4
16.2
8.1
1046
533
513
1749
441
16 Ω / Bridged
800 x 2
4 Ω / Ch.
300 x 4
15.2
7.6
953
400
553
1887
475
8 Ω / Bridged
600 x 2
2 Ω / Ch.
n.r.
4 Ω / Bridged
n.r.
100 V / Ch.
400 x 4
14.4
7.2
944
533
411
1401
353
200 V / Bridged
800 x 2
Mains connector, 230 V CE version
16 A, CEE7
Mains connector, 115 V ETL version
15 A / 5-15P
*1) The amplifier’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and specified here is what
is known as the “Active Power” in the amplifier providing useful, real-world values of power consumption and heat dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features are engaged. Typically this is between 1/4 and 1/3 of rated power. Note that
the max. power condition is very extreme and will not occur during normal operation. Also note that the mains breaker will not be tripped even if operation is in excess
of max. ratings.