8.

Check the adjustment by turning the filter pump
OFF. The heater should shut off immediately. If
it does not, restart the filter pump immediately
and repeat Steps 6 and 7. Check the adjustment
again.

9.

Return the pool temperature control to the
desired temperature.

2E-5. Automatic Flow Control Valve

The flow control valve automatically maintains

the proper flow through the system.

SECTION 3.
Operating Instructions

3A. General Information

With any new pool or spa installation, and at

spring startup, operate the filter pump with the heater
off long enough to completely clean the water. This will
remove any installation residue from the water. Clean
the filter at the end of this operation before starting the
heater.

Caution

Do not use this heater if any part has been

under water. Immediately call a qualified

service technician to inspect the heater and

replace any part of the control system and any

gas control which has been under water.

Attention

N'utilisez pas cet appareil s'il a été plongé dans

l'eau, même partiellement. Faites inspecter

l'appareil par un technicien qualifié et

remplacez toute partie du système de contrôle

et toute commande qui ont été plongés dans

l'eau.

Caution

Should overheating occur or the gas supply fail

to shut off, turn off the manual gas control valve

to the heater.

Attention

En cas de surchauffe ou si l'alimentation en

gaz ne s'arrête pas, fermez manuellement le

robinet d'arrêt de l'admission de gaz.

Caution

Keep all objects off the top of the heater.

Blocking air flow could damage the heater, and

may void the warranty.

WARNING

For your safety, when starting the heater,stand

away from the front of the heater and keep your

head and face well away from the firebox

opening to prevent any risk of personal injury.

3B. Lighting and Shutdown Procedures

(See page 8)

NOTE: If your LP tank runs out of fuel, turn off
gas at the heater. After the tank is refilled, the
heater must be relit following the instructions
found on the heater. DO NOT attempt repairs on
the gas control or heater. Tampering is danger-
ous and voids all warranties.

3C. Setting the Temperature Control

The temperature control (see Figure 4) is cali-

brated at the factory and covers a range from approxi-
mately 70°F to 104°F (21°C to 40°C). Use an accu-
rate pool thermometer to determine the best water
temperature for your uses.

IMPORTANT: The temperature controls cannot

be calibrated in the field. If the control is faulty, shut
down the heater and have a qualified service technician
replace the control. DO NOT use the thermostat switch
to completely shut down the heater.

3D. Seasonal Care

Caution

Do not operate this heater outdoors at

temperatures below 20 degrees Fahrenheit (°F)

(-7 degrees Celsius [°C]).

3D-1. Spring and Fall Operation

During periods when the pool is only going to be

used occasionally, turn the temperature control down
to the MIN setting. This prevents the pool from water
from becoming chilled, and minimizes the time re-
quired to raise the pool water back up to the desired
temperature.

In areas subject to only short freeze periods, turn

off the heater and run the pump continuously for the
length of the freeze period.

If the heater is not going to be used for a long

period of time, shut it down completely. Follow the
instructions found on the inside of the heater, or page 8
of this manual.

Model LHS Above Ground Pool & Spa Heater

Page 7

Содержание Hot Shot LHS

Страница 1: ...se instructions are not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicin...

Страница 2: ...4 2F 1 FlangeInstallation 4 2F 2 ValveInstallation 5 2F 3 Water Chemistry 5 2F 4 Adjusting the Pressure Switch 5 2F 5 Automatic Flow Control Valve 5 3F 6 WiringDiagram 6 SECTION 3 Operating Instructio...

Страница 3: ...in sections of this manual are specific to either United States or Canadian installations and are labeled as such 1B Description The Laars Hot Shot heater is specifically de signed for heating above g...

Страница 4: ...y All gas fired products require correct installation to assure safe operation The requirements for pool heaters include the following 1 Field assembly if required 2 Appropriate site location clearanc...

Страница 5: ...ter runoff with rain gutters on the roof or other measures Do not locate the heater near sprinkler systems that could spray water on it Be sure to locate the heater where oversplash from the pool will...

Страница 6: ...t the trap with a threaded cap which can be removed for cleaning 5 Install an AGA approved manual gas shutoff valve on the outside of the heater jacket for service and safety Do not use a restrictive...

Страница 7: ...l Concentration Levels Test Recommended Level Free chlorine 1 0 to 3 0 ppm Bromine 3 0 to 5 0 ppm pH 7 2 to 7 8 Total alkalinity TA 80 to 120 ppm Calcium hardness CH 200 to 400 ppm Langelier saturatio...

Страница 8: ...Figure 6 LHS Connection Schematic Wiring Diagram 2E 6 Wiring Diagram Model LHS Above Ground Pool Spa Heater Page 6...

Страница 9: ...afety when starting the heater stand away from the front of the heater and keep your head and face well away from the firebox opening to prevent any risk of personal injury 3B Lighting and Shutdown Pr...

Страница 10: ...clockwise to OFF Do not force 1 STOP Read the safety information above 2 Set the thermostat to lowest setting and turn appliance ON OFF switch to OFF 3 Turn gas control knob clockwise until it stops...

Страница 11: ...ement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau 3D 2 Winterizing In areas where freezing tem...

Страница 12: ...r que l appareil fonctionne ad quatement une fois l entretien termin 4B Parts List The following page shows an exploded view to aid in parts identification Please refer to this pages when ordering par...

Страница 13: ...1 2 3 4 5 6 4C Exlpoded View 12 7 8 9 135 F 10 150 F ON OPPOSITE END OF HEAT EXCHANGER 11 13 Model LHS Above Ground Pool Spa Heater Page 11...

Страница 14: ...NOTES Model LHS Above Ground Pool Spa Heater Page 12...

Страница 15: ...NOTES Model LHS Above Ground Pool Spa Heater Page 13...

Страница 16: ...ologies shall not exceed the repair or replacement of defective parts and shall not include transportation to or from factory any labor costs and consequential or incidental damages Ship inoperative p...

Отзывы: