1A. Introduction

The DuraFlow water heater / buffer was

designed and developed specificaly as a companion

for 

modern low mass

, high efficiency heating boilers.

When piped between the supply and return it

provides a twenty gallon buffer in the hydronic

system. This is typically required in systems with

three or more zones to store and release heating

capacity when only a single zone is operating.

As a water heater, it utilizes the rapid heat-up

ability of low mass boilers to immediately convert this

energy to a steady state continuous domestic output.

In single residential applications when provided

with a properly piped mixing valve and flow restrictor

(see Figure 2) it is the hot water source with a twenty

year warranty.

1B. Piping

When the DuraFlow is utilized as a domestic

water indirect, it may be piped as a zoned indirect

utilizing conventional circulator or zone valve piping

and wired with domestic water priority. In this and

buffer applications, the DuraFlow must always be

piped with a thermally trapped tempering valve and

flow restrictor set for applicable boiler input.

When utilized as both a buffer and a domestic

water indirect, the DuraFlow is piped to the heating

system supply and return headers or as the bypass on

systems requiring primary / secondary piping. No

zone valve or circulator should be piped in series with

the DuraFlow. In most applications the boiler pump

(internal or external) serves as the flow means

between the boiler and tank when used as a buffer.

In multi-unit residential applications with a

single hydronic heating system, it serves as the heat

exchanger source for single or multi tank domestic

water storage.

When piped as a buffer and an indirect domestic

water source to a storage tank, a tempering valve and a

flow restrictor are not required.

Figure 1.  Dimensions and Connections.

*Minimum Clearance
  Dimension

Figure 2. Domestic Hot Water Piping.

STORAGE

TANK

OPTION 1

COLD

DURAFLOW

PRESSURE

RELIEF VALVE

AQUASTAT

RECOMMENDED

ANTI-SCALD VALVE

SUCH AS SPARCO

OR DANFOSS

REQUIRED

FLOW

RESTRICTOR

(SUPPLIED)

OPTIONAL RETURN LINE PIPING

OPTION 2

ALTERNATIVE APPLICATIONS

OUT OF

PRODUCTION

Содержание duraflow

Страница 1: ...Installation and Operation Instructions Document 2110A Installation and Operation Instructions for DuraFlow Water Heater 2400 382A A subsidiary of BRADFORD WHITE Corporation OUT OF PRODUCTION...

Страница 2: ...NTS SECTION 1 General Information 1A Introduction 3 1B Piping 3 1C Wiring 5 SECTION 2 Remote Bulb Aquastat Controller 2A Application 5 2B Installation 5 2B 1 Mounting with Boiler Fitting 5 2B 2 Wiring...

Страница 3: ...and buffer applications the DuraFlow must always be piped with a thermally trapped tempering valve and flow restrictor set for applicable boiler input When utilized as both a buffer and a domestic wa...

Страница 4: ...TRANSFORMER DISCONNECT SWITCH L2 L1 LOW MASS BOILER TERMINALS DURAFLOW WATER HEATER AQUASTAT ZONE THERMOSTATS ZONE VALVES NO NC C RELAY G L1 L2 T T Figure 3 Piped as Buffer and Indirect NOTE Pump Ope...

Страница 5: ...breaks to prevent circulator operation When the boiler water temperature rises to the dial setting R to B breaks and R to W makes see Figure 5 2B Installation WARNING CAN CAUSE PROPERTY DAMAGE SEVERE...

Страница 6: ...with the boiler manufacturer s recommendations To adjust insert a screwdriver in the slotted screw type head located beneath the window in the cover Turn the scale to the desired control point 2D Chec...

Страница 7: ...DuraFlow Water Heater Page 7 OUT OF PRODUCTION...

Страница 8: ...s All of above Part A plus Insulation and mechanical components furnished to Laars by other manufacturers such as pumps relays controls gauges etc Such components may carry warranties from their respe...

Отзывы: