START-UP
After installation, you will have to proceed with the first water softener start-up.
1) Put water into the vat of salt (BAV5 = 2.5 Lt - BAV8 = 4LT - BAV10 5Lt - BAV12= 6Lt)
Later this will be done automatically by water softener after each regeneration of the resins.
2) Pour the salt (possibly pads) in the vat, until no longer than 3 \ 4 of the capacity of the
container.
3) Slowly open the tap which feeds the water softener and then open a tap of users
downstream of the softener in order to allow to free the pipes from the air and to perform a
sort of rinsing of the resins (3-5 minutes will be enough)
4) perform a visual inspection of all parts of the softener to exclude the presence of a water
leak.
Periodic maintenance and inspections
Two or three times each year , must be performed the cleaning of the vat of brine for the
removal of sediment and foams which periodically may be formed by the salt deposits .
The resins contained in the blue tank have an average life of five years and after this period
must be replaced by qualified personnel.
To check the status of the resins , perform a test of the water hardness immediately after
the end of a regeneration .
If water were to be " hard" , this could be the signal of the exhaustion of the capacity of the
resins to perform the function of softening and you will have to proceed with the
replacement of the resins .
Regeneration of the resins takes place by means of hydro saline solution formed with the
dissolution of the salt in water, then it will be appropriate to keep under control often the
level of salt present in the vat and fill the brine tank in case the salt should be scarce.
For a correct functioning of the softener we recommend to use only the salt for water
softener system (pads).
If you have installed a filter before the softener , it must be cleaned regularly 3-4 times a
year and, if necessary , replace it with one with the same characteristics .