4. Installation

4.1 Warnings

The  machine  must  be  installed  by  qualified  technical  personnel  authorized  by  La  San
Marco S.p.A.
The  grinder-dispenser  is  delivered  to  the  customers  in  a  suitable  cardboard  and  styro-
foam  package.  The  package  contains  the  grinder-dispenser,  its  accessories,  the  user
manual  and  the  compliance  declaration.  After  having  opened  the  package,  check  the
integrity of the grinder-dispenser and its components; in case of doubt, do not use the
appliance and contact the qualified personnel of the La San Marco S.p.A. service centres.
The package should be disposed of through the proper waste collection centres, in com-

pliance with the laws of the country where it is installed. Do not discard it in the environment. The packing
elements (carton, styrofoam, metal staples, etc.) can be hazardous. Keep away from children!
Place the grinder-dispenser on a perfectly horizontal surface that is sufficiently sturdy to support it, stable and dry. 

4.2 Electrical connections

Instructions for a proper electrical connection of the grinder-dispenser:
• Before connecting the appliance to the power supply, make sure that the tag data of the grinder-dispenser

are the same as the network power supply; the rating tag is located under the grounds collecting tray.

• The connection must be made in accordance with the provisions of the country where the machine is in-

stalled.

• The electrical system prearranged by the customer must be in compliance with applicable standards. The

power socket must be provided with a suitable ground conductor. La San Marco S.p.A. declines any lia-
bility if the prescriptions of the law are not complied with. An improper installation can cause damage or
personal in-jury, for which the manufacturer cannot be considered liable.

• If it is necessary to use adapters, multiple sockets and extensions, use only products in compliance with

the safety standards in force.

• Unwind the power cable completely to avoid overheating it.
• The single-phase grinder-dispensers are provided with a three-conductor power cable and a plug for con-

nec-tion to the power socket.

• For the electrical connection of the three-phase models, install an omnipolar main switch upstream of the

power  supply;  the  main  switch  must  have  the  same  electrical  characteristics  (power  and  voltage)  as
shown on the machine rating tag. The main switch must be able to break the power supply with a con-
tact gap of at least 3 mm.

• The three-phase grinder-dispensers are equipped with a five-conductor power cable. The connection of

the three-phase models must be carried out as follows: (star connection for the models with 400V-3N~
power supply and delta connection for the models with 230V-3~ power supply).

• At the completion of the electrical connection, check that the motor turns in a clockwise direction (look-

ing at the appliance from above); if it turns counterclockwise, reverse two power phases.

• If the power is transformed from 400V-3N~ to 230V-3N~ or vice versa, use the adhesive labels provided

with the machine to update the data shown on the label glued at the end of the power cable.

LEGEND:

L

3

= brown

L

2

= black

L

1

= black

N = neutral (blue)
GI/VE = ground
1 = yellow
2 = blue
3 = white
4 = black
5 = green
6 = brown

Voltage

400V-3N~

L

3

L

2

L

1

N

GI/VE

230V-3~

Connection to

the power socket

Connection to the electronic control unit

inside the machine

L

3

L

2

L

1

N

GI/VE

2

GI BL

BI NE

VE MA

GI BL

BI NE

VE MA

4

6

2

1

1

3

5

4

3

6

5

Содержание SM 90-95

Страница 1: ...ORE 90 95 IT MACINADOSATORE SM 90 95 GB GRINDER DISPENSER SM 90 95 FR MOULIN DOSEUR SM 90 95 DE DOSIERM HLE SM 90 95 ES MOLINILLO DOSIFICATOR SM 90 95 PT MOINHO DOSEADOR SM 90 95 GR O IMETPIKO MY O KA...

Страница 2: ...ENGLISH GRINDER DISPENSER SM 90 95...

Страница 3: ...ferent models pag 17 3 2 Technical characteristics pag 17 3 3 Assembly drawing pag 18 4 Installation pag 19 4 1 Warnings pag 19 4 2 Electrical connections pag 19 4 3 Programming the grinding time Auto...

Страница 4: ...ticle sizes of ground coffee it is thus possible to modify the resistance offered against the passage of water If the ground coffee is made up of excessively coarse particles the serving time is too s...

Страница 5: ...tine maintenance and cleaning operations are reserved exclusively for personnel authorized by the customer and under his own responsibility The machine must not be operated with the fixed and or mobil...

Страница 6: ...asure and dispense the ground coffee it has an adjustment range from 5 to 9 grams or in the increased dose configuration from 6 to 10 grams The amount of ground coffee dis pensed can be adjusted by op...

Страница 7: ...5 HOPPER GATE 6 GRINDER GUARD 7 GRINDING ADJUSTMENT RING 8 ADJUSTMENT RING RELEASE BUTTON 9 DISPENSER 10 DISPENSER LID 11 BATCH ADJUSTMENT KNOB 12 PRESSER 13 GROUND COFFEE DISPENSING LEVER 14 FILTER C...

Страница 8: ...prescriptions of the law are not complied with An improper installation can cause damage or personal in jury for which the manufacturer cannot be considered liable If it is necessary to use adapters m...

Страница 9: ...ng lever it is possible to restart the grinder dispenser after 6 12 18 or 24 batches dispensed 4 4 Grinding adjustment Instructions for a proper adjustment Fill the hopper 3 with the coffee beans and...

Страница 10: ...art the grinder dispenser by pressing the main switch 2 the green LED lights up in the push button showing that the unit is connected The electronic control unit stops grinding at the end of the set t...

Страница 11: ...f materials that the unit is made of In accordance with European Directive 2002 96 EC abusive disposal of the product by the user will result in application of penalties as set forth by local law 7 Wa...

Страница 12: ...out a grind coffee finer b increase the pressing force c increase the batch amount a grind coffee coarser b reduce the pressing force c reduce the batch amount a grind coffee coarser b replace the gri...

Страница 13: ...La San Marco S p A Via Padre e Figlio Venuti 10 34072 Gradisca d Isonzo Gorizia Italy Tel 39 0481 967111 Fax 39 0481 960166 http www lasanmarco com E mail info lasanmarco com...