14
EOLO - COMFORT 80
EN
LEGEND
1
Door for loading pellet
2
Extractable pellet insert
3
Adjustable legs
4
Insert supporting frame
5
Fume exhaust Ø 80 mm
6
Adjustable height of the legs (min-max)
7
Hot air outlet (upper and lateral)
8
Combustible air inlet and cooling
9
Wall cutting dimension (plasterboard/bricks)
11.3
GENERAL INSTALLATION
Fig. 12 - General installation
LEGEND
1
Fireplace insert
2
Minimum lateral distance = 240 mm
3
Minimum rear distance = 190 mm
4
Minimum front distance = 1000 mm
5
Minimum thickness of insulating material = 40 mm
•
Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement,
appropriate measure should be provided (for example a plate for distributing the load).
•
It is obligatory to install the stove away from walls and/or pieces of furniture, with a minimum air flow of 240
mm on the sides and 190 mm on the back, to enable an eficient appliance cooling and a good distribution
•
For safety fire regulations the distances from flammable or sensible to heat objects (sofas, pieces of furniture,
wooden covering, etc...) must be respected, has described in
The probable insulating material to use must have the following technical features:
CARATTERISTICHE
VALORI
Material thickness
40 mm
Screening temperature
1000 °C
Density
245 Kg/m3
Shrinkage at referring temperature (12h)
1,3 % /1000 °C
Cold crushing strenght
1,4 MPa
Bending strenght
0,5 MPa
Thermal expansion coefficient
5,4x10-6 m/mK
Specific heat
1,03 Kj/kgK