EN
79
Display
Operating Procedure
Description
“Technical” Programming
Menu 93.2°C
Enter Password
0000
1
After entering the password and accessing the "Technician" programming menu, rotate the Encoder Knob until
the following is displayed.
Menu 93.2°C
Water Filter Alarm
Settings
2
Press the Encoder Knob to access the menu.
Menu 93.2°C
Water Filter Alarm
ENABLED
3
Press the Encoder Knob to access the menu, rotate the Encoder Knob to choose between
ENABLED and DISABLED,
press the Encoder Knob to confirm the option.
Menu 93.2°C
Water Filter Alarm
Used: 1000L
Threshold: 5000L
4
Press the Encoder Knob to enter the menu, rotate the Encoder Knob to set the desired value, press the Encoder
Knob to confirm the value.
Menu 93.2°C
Coffee Doses
Counter
• This parameter enables the technician
to program an alarm that will alert the
user about the need for maintenance or
replacement of the water filter.
• Once the set volume has been reached,
the error message “Filter Alarm” will be
displayed.
• A value of 0 (zero) disables the filter
alarm parameter.
• This feature can be enabled or disabled.
Filter Alarm
Menu 93.2°C
Eco Mode
Settings
Menu 93.2°C
Water Filter Alarm
Settings
Содержание LEVA S
Страница 97: ...EN 97 ...
Страница 98: ......