2. Press the “0” key.
3. Enter your NEW Manager Combination; re-
enter new combination to confirm.
4. If a mistake is made wait thirty (30) seconds
and repeat steps
1 - 3
.
5. Test unit operation several times before
closing the door.
oPERATioNAL MoDE
oPENiNg ThE LoCK (Manager or User)
1. Enter valid Manager or User combination.
2. The unit will indicate a valid combination entry
with a double signal.
3. Within four (4) seconds open lock by either
rotating the keypad to open position
(clockwise) or turning the handle to the
open position.
4. Pull door open.
• Invalid Combination Entry - Unit will signal
three (3) times.
5. Close the door, and check the locked
status of the container with the handle of
the boltworks.
ChANgiNg CoMBiNATioN (Manager or User)
Always perform this operation with the
door open!
Each combination must be changed
independently.
1. Enter existing combination and hold down the
last digit until unit double signals twice and
the LED stays on.
2. Press the “0” key.
3. Enter your NEW combination, then re-enter
NEW combination to confirm.
4. If a mistake is made wait thirty (30) seconds
and repeat steps
1 - 3.
5. Test unit operation several times before
closing the door.
•
Valid Combination Entry
- Double signal
after valid combination is entered.
•
invalid Combination Entry
- Triple signal
and old combination is still valid.
ACTiVATiNg/REiNSTATiNg USER
(Manager only)
1. Enter Manager combination and hold down
last digit of combination until unit double
signals twice and the LED stays on.
2. PRESS 1. Unit signals twice.
3. Press User number, 1 to 9. Unit signals twice.
4. Enter NEW combination, then re-enter NEW
combination to confirm.
5. If a mistake is made wait thirty (30) seconds
and repeat steps
1 - 4
.
•
Valid Combination Entry
- Double
signal after valid combination is entered.
•
invalid Combination Entry
- Triple
signal and old combination is still valid.
DiSABLE USER (Manager only)
1. Enter Manager combination and hold down
last digit of combination until unit double
signals twice and the LED stays on.
2. PRESS 2. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is temporarily disabled.
5. If a mistake is made wait thirty (30) seconds
and repeat steps
1 - 3
.
DELETE USER (Manager only)
1. Enter Manager combination and hold down
last digit of combination until unit double
signals twice and the LED stays on.
2. PRESS 3. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is deleted.
5. If a mistake is made wait thirty (30) seconds
and repeat steps 1 - 3.
SET/ChANgE TiME DELAy VALUES
1. Enter Manager combination and
hold down
last digit of combination until unit double
signals and the LED stays on.
2.
PRESS 9.
Unit signals twice.
3. Enter two-digit Delay period value (00 to 99
minutes) followed by the two-digit Open
period value (00 to 19 minutes).
• Unit will signal twice, if accepted.
• Unit will signal three times, if invalid.
4. Re-enter the Delay and Open period values,
to confirm.
• Unit will signal twice and feature is active.
NoTE:
Entering 0000 will deactivate the Time
Delay Feature.
NoTE:
If Time Delay is active it may only be
deactivated or delay value decreased in Open
Period.
TiME DELAy – LoCK RESPoNSE
• During the Delay Period the LED will flash
every second.
• During the Open Period the LED will flash
twice a second, and the Entry Device will
beep every 10 seconds.
TiME DELAy oVERRiDE
(If feature is enabled)
• Must add User 9. (See
ADD USER
)
- If User 9 is disabled or deleted, this
feature will no longer function.
• Entry of Override combination during Delay
period will open the lock.
NoTE:
If Time Delay is enabled, User 9 can only
be added during the Open period.
RECEiVE AUDiT (Manager only)
This function requires Serial Interface (P/N
43087) and LGVIEWER Software
1. Plug Interface into PC and open LGView 3X
software on PC.
2. Connect Interface to front of keypad and click
safe icon button on the PC software to
begin acquisition.