background image

(P/N) 760.128 Rev C EN 02/10 • © copyright 2004-2010   

Kaba Mas LLC

 

Page 2 of 2

ADD USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter the Manager combination and 

hold down last digit of combination

 until the 

  lock signals with two sets of double beeps.
2. 

Press 1.

 Lock signals twice.

3. Enter user combination twice. The lock signals twice after each valid entry.
4. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

•  Valid Combination Entry - Double signal after valid six (6) digit combination 
  is entered.
•  Invalid Combination Entry - Triple signal indicates the old combination is still valid. 

DISABLE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter the Manager combination and 

hold down last digit of combination

 until the 

  lock signals with two sets of double beeps.
2. 

Press 2.

 Lock signals once.

3. User is temporarily disabled. (User combination is saved and will be valid 
  if reinstated.)
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.

REINSTATE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter the Manager combination and 

hold down last digit of combination

 until the 

  lock signals with two sets of double beeps.
2. 

Press 1.

 Lock signals once.

3. User is reinstated.
4. If a mistake is made wait thirty (30) seconds and repeat steps 1 - 3.

DELETE USER (MANAGER ONLY)
ALWAYS PERFORM THIS OPERATION WITH THE DOOR OPEN

1. Enter Manager combination and 

hold down last digit of combination

 until the 

  lock signals with two sets of double beeps.
2. 

Press 3.

 Lock signals once.

3. User and combination are removed from lock. (Add User feature is still available.)
4. If a mistake is made wait thirty (30) seconds and repeat steps 

1 - 3

.

WRONG TRY PENALTY

•  Entry of four (4) consecutive invalid combinations starts a five (5) minute 
  delay period.
      - LED flashes red at ten (10) second intervals.
•  At the end of the delay period, two more consecutive invalid combinations will 
  restart the five (5) minute delay period.

BATTERY LOW WARNING

•  Repeated LED flashing and beeping during an opening indicates that the battery is
  low and needs immediate replacement.
•  Uses one (1) 9-Volt alkaline battery only. (Example: Duracell™ or Energizer™ 
  alkaline batteries.) It is recommended that batteries be replaced at least 
  once annually.
• 

Lock contains a non-volatile memory; even with the batteries removed the 

  lock will retain all programming.

For battery replacement instructions, see input unit’s “User Operation” Guide.

Mounting instructions available at www.kaba-mas.com.