COMMAND 7
Audit Lock (AuditGard auditing software, AuditView or LGView,
and a LA GARD Interface Adapter are required)
To audit the Lock using AuditGard AuditView Software, you can
also refer to
AuditGard AuditView User Instructions (787.0310)
.
Start the Auditing Software Program:
1. Plug the USB or Serial Interface Adapter into an available port
on the PC.
2. Plug the appropriate audit cable for the Entry Device into the
USB or Serial Interface Adapter.
3. Start auditing software program.
4. From the auditing software, select the
Configuration
menu on
the Menu bar.
5. Select the appropriate COM port from the list
Audit the Lock:
1. Connect the audit cable to the Entry Device.
2. Click the
safe icon
button or select
Start Acquisition
from the
Actions menu on the Menu bar.
3. Enter Manager combination and
hold down last digit of
combination until unit double signals and the LED stays
on.
4.
PRESS 7
.
The Entry Device will beep once and the audit records will be
transmitted to the PC for display on the screen.
5. Once the audit is complete, disconnect the audit cable from
the Entry Device.
COMMAND 9
Set or Change Time Delay Values
NOTE: If Time Delay is active, it may only be deactivated or the
Delay value “decreased” during an Open Period.
1. Enter Manager combination and
hold down last digit of
combination until Lock double signals and the LED
stays on
.
2.
PRESS 9
.
3. Enter two-digit Delay Period value (00 to 99 minutes) followed
by the two-digit Open Period value (00 to 19 minutes).
NOTE: Entering “0000” will deactivate the Time Delay
Feature.
4. Re-enter the Delay and Open Period values to confirm.
LOCK OPERATIONS
CHANGE COMBINATION
NOTE: Each combination must be changed independently at
the Lock. New combination will not be accepted if it varies from
the current combination by only one digit (+/-). When selecting
a combination, do not use a birthday or other predictable
information that could give correlation between the user and the
combination.
CAUTION: Always perform this operation with the door open, and
test the opening of the Lock with the new combination several
times before closing the door.
1. Enter existing combination and
hold down the last digit until
Lock double signals and the LED stays on
.
2.
PRESS 0
.
3. Enter the NEW combination.
4. Re-enter the NEW combination to confirm.
The NEW combination is now active.
OPEN LOCK
1. Enter valid combination.
2. Open the Lock within four (4) seconds.
OPEN LOCK WITH TIME DELAY SET
1. Enter a valid combination and wait for Delay Period to expire.
2. Once the Open Period begins, enter any valid combination.
3. Open the Lock within four (4) seconds.
TIME DELAY OVERRIDE
(If feature is enabled and User 9
is Activated.)
Entry of the Override combination during the Delay Period will
open the Lock.
NOTE: If Time Delay is active, User 9 can only be added during
an Open Period.
INITIATE SILENT ALARM
(Alarm Box Required)
• To initiate Silent Alarm signal, add or subtract (+/-) 1 to the last
digit of the combination(s).
Example:
Combination: 1-2-3-4-5-6
Duress Combination: 1-2-3-4-5-5 or 1-2-3-4-5-7
The Lock will open without any indication that the alarm signal has
been sent.
BATTERY MAINTENANCE & REPLACEMENT
• It is recommended that batteries be replaced at least once
a year.
• The use of a high quality, name brand alkaline battery
(Energizer® or Duracell®) is recommended.
• If the battery is depleted, follow the battery changing
instructions for the Entry Device you are using. Battery
changing instructions can be found in either the
Electronic Entry Device Installation Instructions
(762.128)
or in the respective Entry Device User Instructions for the Entry
in operation.