MANAGER INSTRUCTIONS

AUDITGARD

66E (LGA) Electronic Combination Lock

AuditGard locks are shipped from LA GARD in Factory Default 
state without Users or features enabled. Refer to the 

AuditGard 

Setup Instructions (742.049)

 if Lock settings have not already 

been programmed. 

Factory Default:

 The Lock must be in the Factory Default state to 

be programmed by the PC software. 
Factory mode functions as follows: 
•  1 key – When pressed, will open the Lock. 
•  0 key – When pressed, prompts the AuditGard Setup software
  to send the configuration settings to the Lock. 
•  All other keys perform no function. 

Setup:

 AuditGard locks must be programmed using the AuditGard 

Setup Software. Once programmed, Manager Combination is 
enabled, and MUST be changed to activate 
the Lock. 

Active:

 The Manager combination must be changed before any 

Manager commands are available. 

PROGRAMMABLE LOCK FEATURES 

MODES

 

(Multiple Modes may be selected.)

• 

Silent Alarm

 

(Alarm Box Required) 

  If enabled, this option will send a signal to an outside alarm 
  system through the LA GARD Alarm Box. 

•  Dual Mode

  If enabled, two combinations will be required to operate 
  the Lock.
  The Manager and one additional User must be active.

•  Time Delay Override

  If enabled, User 9 can override delay period.
  User 9 must be active. 

EXTERNAL SIGNALS

 

(Alarm Box Required. Only one External 

Signal type may be selected.)

 

An external input signal to the Alarm Box will either Disable 
Opening Only or Disable All Access depending on the selection 
programmed for External Signals. 
•  External Signal disables Lock opening with valid combination. 
• 

OR

 External Signal disables Lock opening with valid 

  combination and all Lock commands.

TIME DELAY

•  Delay Period 1 - 99 minutes 
•  Open Period 1 - 19 minutes 

COMBINATION LENGTH 

A combination length from six (6) to nine (9) digits may 
be selected.

NOTE: To maintain the VdS Class 2 and EN 1300 Class B 
certification when the duress alarm feature is used, a combination 
length of 7 digits or longer must be selected.
LOCK USERS 
Manager (ID #1)

•  Open Lock 
•  Change Combination 
•  Enable/Disable Users 
•  Delete Users 
•  Set Time Delay Values 
•  Audit Lock 

Users (ID# 2-9)

•  Open Lock 
•  Change Combination

STANDARD LOCK FEATURES 

Wrong Try Penalty  

•  Entry of four (4) consecutive invalid combinations initiates a five 
  (5) minute delay penalty. 
  Lock responses during the penalty period are as follows:
    -  The LED will flash every ten (10) seconds. 
    -  If any key is pressed, the Lock will flash the LED and beep 
      three times.
•  Once the penalty period has ended, two (2) consecutive invalid
  combinations will initiate another five (5) minute penalty period. 

Low Battery Warning 

•  Repeated audio/visual signals (LED flashes/beeps) during Lock
  opening indicate the battery is low and should be 
  replaced immediately.
•  If the battery level becomes too low to safely operate the Lock,
  pressing any key will initiate the low battery warning. 
  The battery must be replaced before the Lock will operate. 

Dual-Handed

Swing Bolt

Dead Bolt

3750-K

Round Entry

3125

Round Entry

LOCKS

ENTRY DEVICE OPTIONS

8130

(Optional)

3190 Privat

II

 

(Optional)