background image

3. 

Once the alarm time is set, press the SNOOZE key to confirm and exit or wait approximately 8 
seconds for automatic timeout. 

 

TO ACTIVATE / DEACTIVATE THE ALARM: 

Press the AL/HR key. The alarm icon (((

))) will appear/disappear indicating that it is ON or OFF. 

 

Note: 

 the maximum duration of the alarm ringing is 1 minute 36 seconds. 

 

SNOOZE SETTING: 

The snooze time is set as default for 5 minutes by the manufacturer. The snooze mode will be activated from 
the start of next minute after the SNOOZE key was pressed – it does not count the current minute that it was 
pressed in. 

 

To use the snooze feature, simply press the SNOOZE key when the alarm is sounding and the alarm will 
snooze for 5 minutes before automatically sounding again. When the alarm is snoozing, the alarm icon (((

))) 

will start flashing indicating that the alarm is active but is in Snooze mode. 

 

Press the AL/HR key or the MODE/MIN key once to stop the snooze function. 

 

LCD SCREEN 

The Projection clock can display information of date, indoor temperature, seconds and alarm time on 
the LCD only. 

The projection will only display the time

The clock LCD  can alternate between the 4 display modes when pressing and the MODE/MIN key: 
 
 

 

23

Содержание WT535

Страница 1: ...d time The operation of this product is simple and straightforward and by reading this operating manual users will receive the optimum benefits of all its features MODE MIN key AL HR key Battery cover SNOOZE key Adjustable projector Brightness key Direction key Adapter socket FEATURES DCF 77 Radio controlled time with manual setting option 24 hours time display hour minutes seconds 15 ...

Страница 2: ...e display in degree Celsius LED back light SETTING UP The Projection clock can be batteries operated or powered by the provided AC DC adapter BATTERIES INSTALLATION Battery cover Battery compartment 1 Open the battery cover at the back of the Projection clock as indicated above 2 Checking the correct polarization insert 2 x AA IEC LR6 1 5V Alkaline batteries into the battery compartment and replac...

Страница 3: ...he signal in the next following hour Your Projection clock is now operational Note If the batteries are used as the main power source 1 Projected image brightness alarm volume and back light strength would be weaker 2 Battery life time would be much less than 1 year TO USE THE PROJECTOR POWER ADAPTER The unit comes with an adapter unit for using the projector for an extended period of time such as...

Страница 4: ...ness level unless the brightness level is manually changed to a lower brightness level afterwards And the brightness of the projection can be change accordingly to enhance the clarity of the projected time by pressing the key If the Projection clock is battery operated the projection will be ON at the highest brightness level only when the SNOOZE key is pressed The intensity of the brightness leve...

Страница 5: ...setting or in case of a malfunction please remove all batteries from the unit and unplug the AC DC adapter from any power source Wait at least for 3 minutes before powering up the Projection clock again FUNCTION KEYS The radio controlled Projection clock uses the following keys SNOOZE Activate or deactivate snooze function Alarm snooze function Activate the projection brightness at the highest lev...

Страница 6: ...On HOW TO USE THE PROJECTOR The projector projects the current time onto a wall or ceiling preferably within a darkened room It can be adjusted forwards and backwards 180º for maximum projection range The projection image can also be adjusted to 4 upright positions each with a rotation of 90º To project the time onto a flat surface 1 Point the projection lens in the appropriate direction max dista...

Страница 7: ... The Projection clock will automatically start scanning for the DCF 77 frequency signal after the battery is inserted In normal surroundings for example away from interfering sources such as TV sets it takes between 3 5 minutes to receive the signal If after 10 minutes after having inserted the batteries into the alarm clock and the DCF 77 signal is not received then check the following list befor...

Страница 8: ...in a period of 24 hours When the clock is trying to receive the DCF signal the reception icon will flash on the LCD Once the signal is locked the DCF 77 tower icon will stay fixed on LCD and the received time will automatically correct the manually set time As well as the time the date will also be received by the Projection clock and will be displayed accordingly in the calendar section of the LC...

Страница 9: ...ey was pressed it does not count the current minute that it was pressed in To use the snooze feature simply press the SNOOZE key when the alarm is sounding and the alarm will snooze for 5 minutes before automatically sounding again When the alarm is snoozing the alarm icon will start flashing indicating that the alarm is active but is in Snooze mode Press the AL HR key or the MODE MIN key once to ...

Страница 10: ...DCF 77 Tower icon Time Date display Indoor temperature display in degree Celsius Seconds display Alarm time display 24 ...

Страница 11: ...he SNOOZE key to enter the Calendar setting mode or wait for about 8 seconds for automatic timeout Note The Projection clock will still try and receive the signal despite the time being manually set When it receives the signal then the DCF tower icon will stay fixed on the LCD If reception has been unsuccessful then the DCF tower icon will disappear but reception will still be attempted the follow...

Страница 12: ... do not touch any buttons for around 8 seconds The mode will return to normal TIME ZONE SETTING Time zone 0 Central Europe Time zone To change to a different time zone 9 hours 1 In normal mode display press and hold down the MODE MIN key to enter the time setting mode 2 Use the MODE MIN key again to select the desired time zone Each press changes the digits by 1 hour 3 When the desired time zone i...

Страница 13: ...ERY CHANGE It is recommended to replace the batteries in the unit on an annual basis Please help in the preservation of the environment Return used batteries to an authorised depot SPECIFICATIONS Recommended operating temperatures 0 C to 49 C with 0 1ºC resolution Power source Batteries 2 x AA IEC LR6 1 5V Battery life Approximately 12 months Alkaline battery recommended Or AC power INPUT 230VAC 5...

Страница 14: ...uring agents as they may mark the LCD and casing Do not submerge the alarm clock in water Do not attempt to make any repairs to the alarm clock Return it to its original point of purchase for repair by a qualified engineer Opening and tampering with the unit may invalidate its guarantee R TTE Directive 1999 5 EC To be used in EC Member and EFTA States Summary of the Declaration of Conformity We he...