background image

PREPARE FORSETUP 

 

1. Begin set up near your existing network router and a 

computer with high-speed Internet access. 

2. Unpack package contents and insert the temperature probe 

into the TX60U-IT case (see diagram 1). 

 

SETUP AND ACTIVATION 

 

1.  Locate the 

Activation Key Card

 in the package for setup 

instructions and the 

Activation Key

. A unique Activation 

Key is necessary to activate your sensor and Internet 
Gateway. Please keep your Activation Card for reference.  

2.  Visit 

www.lacrossealerts.com

 with your Activation Key 

Card to create your account and activate the product. 

 

ACTIVATION INFORMATION:  

THE INCLUDED

 

ACTIVATION KEY

 is good for  

1 year of

 

ENHANCED SERVICE

 with early warning text 

& e-mail alerts, 

plus 4 more years of

 

BASIC SERVICE

 

for standard remote monitoring for a total of 5 years.  

 

Lost your Activation Key Card? 

 
Contact Customer Support: 

www.lacrossetechnology.com/support/alerts

 

Phone: (608) 785-7920 

 

MEASUREMENT LOG DOWNLOAD 

 
Once the sensor is activated and building a measurement log, 
you can download the data as a comma separated values 
(CSV) file. You must use an application such as Microsoft 
Excel® or Google Docs® that supports comma separated 
values (CSV) formatted files to view the table data. 
 

SELECT A LOCATION TO MOUNT SENSOR 

 

  Select a location protected from water and other 

precipitation. The case is water resistant, not water proof. 

  Place the sensor in a dry, shaded area. Avoid locations with 

direct sun, to prevent inaccurate readings. 

  Fog and mist will not harm the sensor but direct precipitation 

must be avoided.  

 

Note:

 Exposing the sensor case to extreme humidity may 

temporarily disrupt data. The sensor case reads humidity, 
but should not be submerged in water.  

  Select a location within range of the Internet gateway  

(see 

IMPORTANT SETUP & OPERATION NOTES”). 

 
 

CONFIRM CONNECTION BEFORE MOUNTING 

 

 

IMPORTANT:

 Before permanently mounting…

Test sensor 

in the desired mounting location for at least 1 hour

 to 

confirm good reception. Confirm consistent readings on your 
account at 

www.lacrossealerts.com

 before permanently 

mounting. 

Move the sensor closer to the Internet 

Gateway if the signal is lost or not received.

 

 

Mount the sensor after the activation process  

(see “SETUP AND ACTIVATION”). 

MOUNT TO WALL WITH SCREWS 

 

1. Remove the mounting bracket  
2. Place bracket over the desired location.  
3. Mark mounting surface with a pencil through 

the 2 holes of the bracket. 

4. Screw bracket onto surface and  

tighten screws to bracket. 

5. Insert the sensor back into the bracket. 

 

FREE STANDING 

 
Attach the mounting bracket to the bottom or top of 
the sensor and place it on any flat surface. 
 

PLACEMENT OF TEMPERATURE PROBE (Optional) 

 

  Confirm that the end of the probe cable is secured in the 

socket inside the sensor (See Diagram 1). 

  Insert the dry temperature probe 

MODEL #: D000.101.BG

 

on 6 Ft. cable into a refrigerator or freezer, or dry soil, etc. 
for a separate reading of air or soil temperature.  

  The dry temperature probe wire is not for use in water.  

**An optional wet probe should be used to measure wet 
environments (sold separately). Check your retailer for 
availability: MODEL #: 

D000.102.BG

 or 

D000.103.BG

 

  Loosely coil and secure extra cord with a twist tie or secure 

with tape (not included). 

 

IMPORTANT SETUP & OPERATION NOTES 

 

  The sensor has a wireless range of 200 feet (60.96 m).  The 

200 ft. range equates to open air with no obstructions, and 
that radio waves DO NOT curve around objects.  Actual 
transmission range will vary depending on what is in the path 
of the signal. Each obstruction (roof, walls, floors, ceilings, 
etc.) will effectively cut signal range in half.   

  Metal, stucco, and some types of glass can reduce signal 

range by as much as ¾ or more, compared to the ½ 
reduction typical of most obstructions.  It is possible to 
receive a signal through these materials, however maximum 
range will be reduced due to their tendency to absorb or 
reflect a much larger portion of the sensor’s signal. 

  The sensor measures and updates the temperature and 

humidity on the LCD every 6 seconds.  

Note: The new measurement is reported to your account at 
intervals that you select using your online account.  

 

BATTERY REPLACEMENT 

 

1. Remove the battery cover by sliding the cover down. 
2. Observing the correct polarity install 2-AAA batteries. The 

batteries will fit tightly (to avoid start-up problems make sure 
they do not spring free). 

3. Do not mix old and new batteries.  
4. Do not mix alkaline, lithium, standard or rechargeable 

batteries. 

5. Replace the battery cover by sliding upwards and check that 

it is securely fitted.  

 
 
 
 
 

Содержание TX60U-IT

Страница 1: ...nt IMPORTANT Product set up and activation instructions are online www lacrossealerts com 6 IMPORTANT Activation Key Card is required for set up activation of every device Do not throw away ADDITIONAL EQUIPMENT NOT INCLUDED Two fresh AAA IEC LR03 1 5V Alkaline batteries Two sided tape as needed Browser with high speed Internet Network router FEATURES AND MEASUREMENTS Diagram 1 A Wireless Ambient T...

Страница 2: ...after the activation process see SETUP AND ACTIVATION MOUNT TO WALL WITH SCREWS 1 Remove the mounting bracket 2 Place bracket over the desired location 3 Mark mounting surface with a pencil through the 2 holes of the bracket 4 Screw bracket onto surface and tighten screws to bracket 5 Insert the sensor back into the bracket FREE STANDING Attach the mounting bracket to the bottom or top of the sens...

Страница 3: ...ng the limited warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume the remaining original warranty or ninety 90 days whichever is longer La Crosse Technology Ltd will pay all expenses for labor and materials for all repairs covered by this warranty If n...

Страница 4: ...book must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their...

Отзывы: