11 

 

 

Weather Mode 

 
1) Weather 

forecast 

 sunny, partly cloudy, cloudy, rainy & 

stormy 

2) 

Pressure bar chart 

 shows pressure level & trend of the past 

6 hours 

3) 

Barometric pressure - pressure reading (refer SETUP mode 
for pressure unit setting) 

4) Pressure 

trend 

 rising, steady or falling 

5) 

Daily, weekly or monthly rainfall in inch or mm 

6) 

Total Rainfall in inch or mm 

7) 

Wind chill in degree F or C 

 

12 

 

8) 

Average wind speed in m/s, knots, mph & km/h 

9) Wind 

direction 

10)  Gust wind speed in m/s, knots, mph & km/h 
11)  Outdoor or indoor temperature in degree C or F  

(with trend 

 rising, steady or falling)  

12)  Outdoor or indoor humidity                                                         

(with trend 

 rising, steady or falling) 

13)  RF signal indicator 

 flashes when it is searching for RF signal 

from remote sensor; stays on when it has successfully 
received RF signal from the remote sensor 

14) Clock 

 displays in 24 or 12 hour format                                     

(refer 

Time format

 in SETUP mode for setting) 

15) Alarm 

icon 

 appears when alarm is enabled 

16)  Moon phase with stars icons 

 New moon (the moon icon 

disappears), Waxing Crescent moon, First Quarter Moon, 
Waxing gibbous moon, Full Moon, Waning gibbous Moon, 
Last Quarter Moon & Waning Crescent Moon 

17) Calendar 

 displays in Day/Month or Month/Day format (Refer 

SETUP mode for setting)  

18)  Channel number of outdoor remote sensor 

 channel 1, 2 or 3 

(Default channel 1 for wind meter) 

 

 

 

 
 

Содержание 308-807

Страница 1: ...cord 5 Volt 4 Wireless Wind Thermohygro transmitter W132 Q 5 Wireless Rain Gauge W174 Q INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by La Crosse Technology INSTANT TRANSMISSION offers you an immediate update of all the outdoor data measured from the transmitters follow the climatic variations in real time This product offers ...

Страница 2: ... out the battery insulation sheet from the bottom of the IR remote control x PHOTOS Save photos Jpeg to a USB flash drive SD secure digital or MMC multi media card memory cards Insert memory device into the wireless display x WIND THERMOHYGRO SENSOR Select a mounting location within range of the wireless display Calibrate the direction of the wind Hold the wind vane pointing due north and do not a...

Страница 3: ...e Language Select between English Dutch French Slideshow Time Select between 3s 5s 15s 1 min 15 min 1 hour for photo slideshow mode Transition Effect Select the transition effect of the photo slideshow mode Chose from Random Fading Expand Top Expand Bottom Expand Middle Off Bottom to Top Top to Bottom Left to Right Right to Left Door Close Door Open Horizontal and Vertical Photo repeat mode Select...

Страница 4: ...lect between m s knots mph km h Sea Level Pressure Adjust the sea level pressure for your local area see chart below Pressure must be set in hPa but can be displayed in inHg Pressure Unit Select pressure unit between hPa mmHg inHg or mb Remote Channel Display Automatic Show indoor and the channel s being registered Indoor Channel 1 only Shows only channel 1 reading only Indoor Channel 2 only Shows...

Страница 5: ...t is off Turn on the wireless display and enter PHOTO mode to view the photos x Press the LEFT ARROW or RIGHT ARROW button to view the next or previous photo x Press SLIDESHOW to enable or disable the slideshow x Press ZOOM IN to enlarge the photo press repeatedly to resume to the original photo size x Press ROTATE to rotate the photo To set the time interval transition effect of the slideshow ent...

Страница 6: ...ng steady or falling 12 Outdoor or indoor humidity with trend rising steady or falling 13 RF signal indicator flashes when it is searching for RF signal from remote sensor stays on when it has successfully received RF signal from the remote sensor 14 Clock displays in 24 or 12 hour format refer Time format in SETUP mode for setting 15 Alarm icon appears when alarm is enabled 16 Moon phase with sta...

Страница 7: ...with trend rising steady or falling 7 Indoor or outdoor humidity with trend rising steady or falling 8 RF signal indicator flashes when it is searching for RF signal from remote sensor stays on when it has successfully received RF signal from the remote sensor 9 Photo s from USB flash drive SD or MMC memory card Calendar Mode x Press LEFT ARROW or RIGHT ARROW button to show the calendar of the pre...

Страница 8: ...thin the effective transmission range 246 ft open air Note To mount the anemometer you need a mast not supplied about 1 1 25 inches 2 54 3 1 cm in diameter and the hardware necessary to fasten it to the mounting location x Mount and ground the mast as directed in the instructions provided by the mast 16 x Place the supplied U shape metal plates around the mast Insert 4 pieces of the supplied Hex s...

Страница 9: ...ing as this may cause low rain readings x Mount in an area not blocked on the top or sides so rain can freely reach the rain gauge for example not under an overhang or too close to a building or fence x To prevent false rainfall readings caused by water splashes do not choose a location that is not level or that is too close to the ground a swimming pool lawn sprinklers or anywhere water might acc...

Страница 10: ... gust Range 0 67 mph 0 30m s 0 108 km h 0 58 3 knot Transmission Distance 246 feet 75 meters distance to the wireless display monitor in open space with no obstructions NOTE Gust is the max gust in a 10 minute period The max gust reading will remain visible for 10 minutes unless a higher gust is reported in that time frame Rainfall Range 0 393 66 inch 0 9999 mm Transmission Distance 131 feet 40 me...

Страница 11: ...horized service center La 22 Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring...

Страница 12: ...o conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interferenc...

Отзывы: