background image

Model: 308-1425C             www.lacrossetechnology.com/support              

 pg. 10 

 

SEARCH FOR OUTDOOR SENSOR 

 

 

Hold the HEAT/DEW button to search for the outdoor sensor.  

 

The strength signal icon will animate until the sensor signal is received 

or for 3 minutes if no signal available.  

 

 

 

 

MAX/MIN TEMPERATURES 

 

The Forecast station provides the daily minimum and maximum 

temperatures each day starting at midnight (12:00 AM). The Forecast 

station automatically resets the min/max temperatures at midnight (12:00 

AM).   

 

View MIN data:  Press and release the ▼ button to view the minimum 

Indoor and Outdoor Temperatures.   

Reset MIN data:  Hold the ▼ button for five seconds and the Indoor and 

Outdoor Minimum Temperatures will be reset.  

 

View MAX data:  Press and release the ▲button to view the maximum 

Indoor and Outdoor Temperatures.   

Reset MAX data:  Hold the ▲ button for five seconds and the Indoor and 

all Outdoor Maximum Temperatures will be reset.  

 

Note: The temperature areas will show dashes briefly then return to 

current temperatures.   

 

HEAT INDEX/DEW POINT 

 

The HEAT/DEW button toggles between Heat Index, Dew Point, and Mold 

Risk. Each feature will display for 10 seconds then return to default display 

if the button is not pressed again. 

 

View Heat Index: From a normal display, press the HEAT/DEW button 

once and Heat Index will show in place of the outdoor temperature. 

Note: Heat index will be the same number as the temperature until the 

outdoor temperature is above 80 °F (26.7°C).  

 

View Dew Point Temperature: From a normal display, press the 

HEAT/DEW button twice and Dew Point will show place of the outdoor 

temperature. 

Note: Dew Point is lower than the actual temperature. 

Содержание 308-1425C

Страница 1: ...S COLOR FORECAST STATION Table of Contents INITIAL SETUP 3 LCD FEATURES 4 BUTTONS 4 Down Button 4 TIME SET Button 5 SNOOZE LIGHT HI LOW OFF Button 5 HEAT DEW SENSOR SEARCH button 5 UP Button 5 ALERT Button 5 ALARM Button 5 SET TIME DATE ETC 6 BACKLIGHT HI LO OFF 7 INDOOR COMFORT INDICATOR 7 TX141TH Bv2 Sensor ...

Страница 2: ...ALERT SOUNDS 9 SEARCH FOR OUTDOOR SENSOR 10 MAX MIN TEMPERATURES 10 HEAT INDEX DEW POINT 10 TEMPERATURE TREND ICONS 11 MANUAL WWVB RADIO CONTROLLED TIME SEARCH 11 TIME ALARM 11 DEACTIVATE TIME ALARM 11 SNOOZE 12 LOW BATTERY ICON 12 SPECIFICATIONS 12 POSITION THE FORECAST STATION 13 POSITION OUTDOOR SENSOR 13 CARE AND MAINTENANCE 13 WARRANTY AND SUPPORT INFORMATION 14 FCC STATEMENT 14 ...

Страница 3: ... the forecast station Step 3 Optional Insert 3 AAA batteries not included into the forecast station Step 4 After 5 minutes place the sensor outside in a shaded location Maximum transmission range is 300 ft 91 meters Note If the outdoor temperature area shows dashes after 3 minutes hold the HEAT DEW button on the weather station to search for the sensor Press the TX button on the sensor to send a s...

Страница 4: ...values Default Time Display Press to display minimum temperature humidity Hold 2 seconds to clear minimum temperature humidity memory Temperature Alert Press to disarm alerts WWVB Time Alarm Calendar Color Animated Forecast Tendency Indoor Temp Hum Trend Min Max Indoor Outdoor Temperature Alerts Remote Temp Hum Trend Min Max Heat Index Dew Point Indoor Comfort Indicator ...

Страница 5: ... view Heat Index Press twice to view Dew Point Hold to search for Outdoor sensor UP Button Setting Press to increase the values during setting Hold 2 seconds to quickly adjust values Default Time Display Press to view maximum temperature humidity Hold 2 seconds to clear maximum temperature humidity memory Temperature Alert Press to arm alerts ALERT Button Default Time Display Press to toggle betwe...

Страница 6: ... to adjust values 3 Press the TIME SET button to confirm adjustments and move to the next item Setting Order 1 WWVB time signal On Off 2 Time Zone 7 time zones 3 DST Daylight Saving Time On Off 4 12 24 hour time format 5 Hour 6 Minutes 7 Year 8 Month 9 Date Fahrenheit Celsius WWVB Time On Off Time Zone DST ON OFF 12 24 Time Format Hours Minutes ...

Страница 7: ...FF button to adjust the backlight When using battery power only Press the HI LOW OFF button for 10 second backlight INDOOR COMFORT INDICATOR The indoor comfort display reads the indoor humidity to determine comfort level The weather station will display one of five indicators Status Indicator Color Too Humid First Arrow Blue Humid Second Arrow Blue Good Third Arrow Green Dry Fourth Arrow Orange To...

Страница 8: ...e averaged hourly and daily then stored in nonvolatile memory The three hour pressure icon change is based off of the last four average hourly readings The icons forecast the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates FORECAST TENDENCY INDICATORS Working with the forecast icons the tendency indicators let you know if the weather is improvi...

Страница 9: ...ing INDOOR LOW alert will flash Press the or buttons to choose the value and press the ALERT button to confirm and exit Note After selecting temperature alert values use the next step to turn individual alerts ON or OFF ARM DISARM TEMPERATURE ALERTS In normal time mode press and release the ALERT button to toggle between o Outdoor HI o Outdoor Lo o Indoor HI o Indoor LO Press the button to arm the...

Страница 10: ...nd release the button to view the maximum Indoor and Outdoor Temperatures Reset MAX data Hold the button for five seconds and the Indoor and all Outdoor Maximum Temperatures will be reset Note The temperature areas will show dashes briefly then return to current temperatures HEAT INDEX DEW POINT The HEAT DEW button toggles between Heat Index Dew Point and Mold Risk Each feature will display for 10...

Страница 11: ...h For information about WWVB visit www nist gov pml div688 grp40 wwvb cfm TIME ALARM Hold the ALARM button for 5 seconds to enter the alarm time set mode 1 The alarm hour digit will flash in the time display 2 Press and release the or buttons to select the hour 3 Press and release the ALARM button to set the minutes The minute digits will flash 4 Press and release the or buttons to select the minu...

Страница 12: ...isplayed in Indoor Temperature section replace batteries in the forecast station SPECIFICATIONS Indoor Temperature Range 32 F to 122 F 0 C to 50 C Humidity Range 10 99 RH Interval About every 30 seconds Outdoor Temperature Range 40 F to 140 F 40 C to 60 C Alkaline Batteries 20 F to 140 F 28 8 C to 60 C Lithium Batteries 40 F to 140 F 40 C to 60 C Note Temperatures below 20 F 28 8 C require Lithium...

Страница 13: ...tdoor sensor The maximum transmitting range in open air is 300 feet 91 meters Obstacles such as walls windows stucco concrete and large metal objects can reduce the range POSITION OUTDOOR SENSOR Mount the outdoor sensor on a north facing wall or in any well shaded area Under an eave or deck rail is preferred The maximum transmitting range to the forecast station is over 300 feet 91 meters in open ...

Страница 14: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV tech...

Отзывы: