111
To re-enable the buzzer:
1.
When the BUZZER OFF icon is shown on LCD, press and hold the SET key
until the BUZZER OFF icon disappears.
2.
Press ALARM or HISTORY key once to return to the normal display mode. The
"BUZZER OFF" icon will no longer be shown. Then the alarm will sound
normally.
LOW BATTERY INDICATOR
The low battery indicator of the weather station and the transmitter will be displayed at
the top and bottom portion of the LCD respectively when the battery power is low. It is
recommended to replace the batteries in all units on an annual basis to ensure
optimum accuracy of the system.
Note:
•
After battery change, both the Weather Station and the transmitters need to be
reset (see note ”Setting up”)
•
The History data record will be clear after the battery change.
OUTDOOR TRANSMITTER 868 MHz RECEPTION CHECK
The outdoor temperature, humidity, wind data are transmitted from thermo-hygro
transmitter every 4.5 seconds; the rainfall data are transmitted from the rain sensor
every 6.25 seconds. The receiver will be synchronized to the thermo-hygro transmitter
and rain sensor then. The transmission range (supposedly up to about 100 metres) of
the thermo-hygro transmitter/ rain sensor may be affected by the ambient temperature.
At cold temperatures the transmitting distance may be decreased. Please keep this in
mind when placing the transmitter and the rain sensor.