53 

Wrong Channel:  

The channel number is displayed in the lower right corner of 

your unit above the humidity reading.  Use the CH/+ key to move this to Channel 
1.  If this is set at Channel 2 or 3, you may be getting no signal at all.  Or, because 
of the popularity of our Weather Stations, it is possible for your unit to pick up a 
signal from a neighbor’s sensor. 
If you are on Channel 1 and you believe the temperature is still inaccurate, bring 
the transmitter indoors and let it set for a couple hours to reach room temperature.  
Compare this reading with the reading on your display.  A temperature difference 
of +/- two degrees is considered normal.  Therefore, if your sensor is reading two 
degrees high and your display is reading two degrees low, you may experience a 
4-degree difference between La Crosse Technology units.  All electronics have 
similar tolerances within their products. 

 

Distance: 

 It may also be that the distance between the transmitter and the 

receiver is too great or has too many obstacles between the units to allow the 
signal to reach the transmitter.  Please refer to Temperature Reading Problem 1 
regarding sensor placement. 

 

Worn out: 

 Also, your transmitter may be defective or worn out due to age or 

weather conditions. If you continue to have problems, please call for technical 
support. 

 

 

54 

Outdoor Temperature Displays as OFL 
Batteries

: Be sure you have good alkaline batteries for both the sensor and the 

base station. 

 

 If the display shows OFL, your batteries may be weak or dead.  Follow the “Proper 
Restart” instructions.  If you continue to have problems, please call for technical 
support. 

 

Outdoor Readings are Totally Blank 

If only the Outdoor Readings portions of the indoor unit are totally blank (not 
showing dashes or OFL), this may a problem with the indoor unit or the batteries.  
Remove all batteries from all units and follow the directions in the Proper Restart 
section above, using fresh batteries.  If the problem continues, contact Customer 
Support for further instructions. 

 

Indoor Readings 
Indoor Temperature/Humidity Displays as --.- (dashes) or is missing 
Batteries: 

Be sure you have good alkaline batteries for both the sensor and the 

base station. This is almost always a power issue. 

 

Indoor Temperature/Humidity is Blank 

If only the Indoor Readings portion of the indoor unit is totally blank (not showing 
dashes or OFL), this may a problem with the indoor unit or the batteries.  Remove 

 

55 

all batteries from all units and follow the directions in the Proper Restart section 
above, using fresh alkaline batteries.  If the problem continues, contact Customer 
Support for further instructions. 

 

Indoor Temperature/Humidity Displays as OFL

 

Batteries: 

Be sure you have good alkaline batteries for both the sensor and the 

base station. This is almost always a power issue. 

 

Minimum and Maximum Records 
Viewing the Indoor Minimum and Maximum Records  

Press and release the MIN/MAX button to view the indoor and outdoor Min and 
Max temperatures. 

 

Resetting the Minimum and Maximum Records 

To reset the indoor MIN and MAX temperatures press and hold the MIN/MAX 
button for 5 seconds.  The temperature and humidity will then reset to the current 
values. 

 

Viewing the Outdoor Minimum and Maximum Records from a Different 
Sensor 

Press the CH/+ button to view records from up to three different sensors.  Select 
the channel then the MIN/MAX button. 

 

 

56 

Time and Date Information 
Time is Not Accurate 

 

Scratch Guard

 

If you have not yet installed the batteries or plugged in the weather station and it 
shows a time, remove the scratch-guard from the LCD panel.  

 

WWVB Signal 

This weather station receives a signal from Ft. Collins, Colorado (WWVB) to set it 
to atomic time. Make sure that the RCC/WWVB feature is set to ON.  This is 
indicated by a “WWVB” above the minute.  If WWVB is not displayed, the feature 
is OFF.  To turn it on, enter the programming mode by pressing and holding SET 
key until the unit flashes. A WWBV tower icon       will also be flashing.   
Press SET key three additional times until RCC and the on/off indicator are 
flashing.  Press the CH/+ key to turn this feature ON.  Press SNOOZE to return to 
normal display. 
Sometimes, due to adverse weather or atmospheric conditions, you will not be 
able to receive a signal immediately and may have to wait overnight for the signal. 
The best way to get a signal is to put your weather station in a window with the 
front or back facing Colorado until you see the tower icon appear.  

 
 
 

Содержание WS-9611U-IT

Страница 1: ...y information 44 FAQ 47 INVENTORY OF CONTENTS 1 Wireless Weather Station WS 9611U IT 2 Wireless Temperature Sensor TX29U IT and mounting bracket 3 Instruction manual This product offers INSTANT TRANSM...

Страница 2: ...led time code reception is automatically started This takes typically between 3 5 minutes in good conditions If after 10 minutes the WWVB time has not been received press the SET key to manually enter...

Страница 3: ...eather Station uses 2 x AA IEC LR6 1 5V batteries To install and replace the batteries please follow the steps below 11 1 Remove the cover at the back of the Weather Station 2 Insert batteries observi...

Страница 4: ...larm time even inside snooze mode Stop the alarm during alarm ringing Backlight on 15 MIN MAX Press and release to toggle between MIN MAX and current temperature humidity values for selected outdoor t...

Страница 5: ...ing Time setting flashing 19 DAYLIGHT SAVING TIME DST ON OFF SETTING Note The DST default is ON meaning that the received time will automatically be adjusted according to Daylight Saving Time in the s...

Страница 6: ...ived the date is automatically updated However if the signals are not received the date can also be set manually 23 The year starts flashing Use the CH key to set the year 1 Press the SET key again to...

Страница 7: ...utes flashing 27 1 Use the CH key to set the snooze time Each pressing of the key will increase the snooze time by 5 minutes The snooze can also be set OFF when the OFF digit is being displayed 2 Conf...

Страница 8: ...s a sun or raining cloud there will be no change of icon if the weather gets any better with sunny icon or worse with rainy icon since the icons are already at their extremes The icons displayed forec...

Страница 9: ...istered a change in temperature and air pressure 34 78 8 F 26 C 66 2 78 6 F 19 25 9 C 50 66 F 10 18 9 C 32 49 8 F 0 9 9 C 32 F 0 C Sunny Cloudy Rainy 35 Full Moon Large Waning Gibbous Small Waning Gib...

Страница 10: ...z RECEPTION If the outdoor temperature data is not being received within 3 minutes after setting up the display shows F and on the outdoor section of the wireless weather station after 3 attempts duri...

Страница 11: ...ansmission range up to 330 feet 100 meters Power consumption Wireless Weather Station 2 x AA IEC LR6 1 5V Wireless Temperature Sensor 2 x AA IEC LR6 1 5V Battery life cycle Approximately 24 months Alk...

Страница 12: ...products web www lacrossetechnology com Question Instructions Please visit www lacrossetechnology com 9611it 47 FAQ WS 9611U IT TX29U IT Congratulations on purchasing this state of the art Weather St...

Страница 13: ...button to adjust the minutes Press SNOOZE SUN bar to return to normal display Activating and Deactivating the Alarm Press and release the ALM button to activate the alarm 51 When is showing above the...

Страница 14: ...alkaline batteries for both the sensor and the base station This is almost always a power issue Indoor Temperature Humidity is Blank If only the Indoor Readings portion of the indoor unit is totally b...

Страница 15: ...cons that will be displayed Sunny indicates that the weather is expected to improve not that the weather will be sunny Sun with Clouds indicates that the weather is expected to be fair not that the we...

Страница 16: ...ted object push pin to press this into place Plug the adapter into a live electrical outlet If these steps do not correct the problem contact our technical support department for assistance 63 Segment...

Страница 17: ...registering with your unit as the primary sensor To confirm that your sensor is the primary sensor after the Proper Restart you may place your sensor in a refrigerator or freezer and recheck the displ...

Отзывы: