background image

 

24 

LOW BATTERY INDICATORS  

Low battery indicator will show on the LCD when the batteries of weather station or transmitter 
require changing. 

 

THERMO-HYGRO TRANSMITTER 

The reception distance of the thermo-hygro transmitter may be affected by the temperature. At 
cold temperatures the transmitting distance may be decreased. Please bear this in mind when 
placing the transmitter. 

 

915 MHz RECEPTION 

The weather station should receive the outdoor data within 80 seconds after set-up.

 

If the outdoor 

data is not received 80 seconds after setting up (or the outdoor 

temperature shows “- - -” during 

normal operation), please check the following points: 
1. 

The distance of the weather station or transmitter should be at least 5 to 6.5 feet (2 

–3 

meters) away from any interfering sources such as computer monitors or TV sets. 

2. 

Avoid positioning the weather station onto or in the immediate proximity of metal window 
frames. 

3. 

Using other electrical products such as headphones or speakers operating on the same 
signal frequency (915 MHz) may prevent correct signal transmission and reception. 

4. 

Neighbors using electrical devices operating on the 915 MHz signal frequency can also 
cause interference. 

 

Note:

 

When the 915 MHz signal is received correctly, do not re-open the battery cover of either the 
transmitter or weather station, as the batteries may spring free from the contacts and force a false 

Содержание WS-9257U-IT

Страница 1: ... of outdoor temperature humidity and display of indoor temperature humidity and air pressure It also functions as a normal clock with calendar display and alarm setting In addition weather forecast sunrise sunset time as well as the moon phase are shown This innovative product is ideal for use in the home or office FEATURES The weather station Hanging hole Battery compartment Foldout stand ...

Страница 2: ... Outdoor temperature display with MIN MAX recordings time and date All MIN MAX recordings can be reset Indoor and outdoor humidity display in RH Display of relative or absolute air pressure Relative air pressure inHg with adjustable reference value Relative air pressure history for the past 12 hours Display of sunrise time sunset time and sun duration time in 93 USA cities and 6 Canadian cities Di...

Страница 3: ...1 Insert the batteries into the Temperature transmitter Keep the transmitter 5 10 feet from the Weather Station during set up 2 Within 45 seconds insert batteries into the Weather Station Once the batteries are in place all segments will light up briefly The time will be displayed as 12 00 If this is not displayed within 80 seconds remove the batteries from both units for 2 minutes and start again...

Страница 4: ... feet 100 meters distance open air no obstructions 6 Test the weather station and the transmitter in the positions they will be located for one hour before permanently mounting If the outdoor temperature signal goes to dashes restart from step 1 and try a new location HOW TO INSTALL AND REPLACE BATTERIES IN THE THERMO HYGRO TRANSMITTER The outdoor thermo hygro transmitter uses 2 x AAA IEC LR3 1 5V...

Страница 5: ...r removing the batteries before reinserting otherwise start up and transmission problems may occur In the event of changing batteries in any of the units all units need to be reset by following the setting up procedures BATTERY CHANGE It is recommended to replace the batteries in all units regularly to ensure optimum accuracy of these units Battery life See Specifications below Please participate ...

Страница 6: ...it alarm setting mode and country state city setting mode To toggle between relative and absolute air pressure value display key To increase change values in setting modes To stop the alarm sound MIN MAX key To switch among the display of MIN MAX outdoor temperatures and MIN MAX indoor temperatures To decrease change values in setting modes SET key key MIN MAX key ALARM key SUN key ...

Страница 7: ...rm sound To exit manual setting mode and country state city setting mode SUN key To switch among the display of date normal mode seconds sun duration and city Press and hold for 2 seconds to enter country state city setting mode To stop the alarm sound To exit manual setting mode and alarm setting mode LCD SCREEN The LCD screen is split into 3 main sections displaying the information for indoor an...

Страница 8: ...tor Weather forecast icon Weekday Weather tendency indicator Time Low battery indicator transmitter Sunrise time Sunset time Outdoor data signal reception indicator Outdoor temperature in F Air pressure history bar graph Indoor temperature in F Indoor humidity display in RH Outdoor humidity display in RH Relative and absolute air pressure display Low battery indicator weather station Outdoor MIN M...

Страница 9: ... SET key LCD contrast setting Daylight Saving Time DST ON OFF Manual time setting Calendar setting Relative air pressure value setting Press and hold the SET key for about 2 seconds to advance to the setting mode LCD CONTRAST SETTING The LCD contrast can be set within 8 levels from LCD 0 to LCD 7 Default is LCD 3 1 The digit starts flashing 2 Press the or MIN MAX key to select the level of contras...

Страница 10: ...light saving time DST function can be set ON OFF Default setting is ON 1 ON will flash on the LCD with dSt displayed 2 Use the or MIN MAX key to turn the daylight saving time function ON or OFF 3 Confirm with the SET key and enter the Manual Time setting or exit the setting mode by pressing the ALARM key or SUN key MANUAL TIME SETTING Hour flashing Flashing Minutes flashing ...

Страница 11: ...to decrease the value Keep holding the key allows the value to advance faster 5 Confirm with the SET key and enter the Calendar Setting or exit the setting mode by pressing the ALARM key or SUN key CALENDAR SETTING 1 The year digits will start flashing Use the key to increase or MIN MAX key to decrease the value The range runs from 2011 to 2025 default is 2011 Keep holding the key allows the value...

Страница 12: ...etting or exit the setting mode by pressing the ALARM key or SUN key Note Weekday is displayed accordingly above the time in short form from Monday to Sunday MO TU WE TH FR SA SU RELATIVE AIR PRESSURE VALUE SETTING The default relative air pressure value is 29 91 inHg This can be manually set to another value within the range of 28 30 30 80 inHg for a better reference 1 The current relative air pr...

Страница 13: ... the SUN key for 2 seconds to enter the Location setting mode 2 The short form of country name will start flashing Use the key or MIN MAX key to select the country Note See the Country State City codes list at the end of this handbook 2 countries 99 cities can be chosen from Every country city is displayed in short code default country is USA The states abbreviations are in brackets for USA Countr...

Страница 14: ...MIN MAX key to select the state 3 After the state has been selected press the SUN key to enter the city setting 4 The 3 letters city abbr will start flashing Use the key or MIN MAX key to select the city 5 Confirm with the SUN key The city s sunrise sun duration and sunset time will be displayed in a few seconds State code flashing City code flashing Country code flashing ...

Страница 15: ... back to normal date display 7 User can exit the setting mode by pressing the SET key or ALARM key without saving the changes Sunset time of selected city Sunrise time of selected city Sun duration hours minutes Sunset icon Sunrise icon ...

Страница 16: ...ey to enter the city setting 2 The city code 3 letters abbr will start flashing Press the or MIN MAX key to select the city 3 Confirm with the SUN key The city s sunrise sun duration and sunset time will be displayed in a few seconds Country code flashing City code flashing ...

Страница 17: ...g the SET key or ALARM key without saving the changes ALARM SETTING To set the daily alarm 1 Press and hold ALARM key for 2 seconds until the alarm time shown Alarm time flashing Alarm indicator ON Sunset time of selected city Sunrise time of selected city Sun duration hours minutes Sunset icon Sunrise icon ...

Страница 18: ... alarm sounding is 2 minutes Press any key will stop the alarm sound TO EXIT SETTING MODE To exit the setting mode wait for automatic timeout to return to normal time display DISPLAY OF SUN DURATION TIME 1 In normal date mode press the SUN key twice to display the sun duration time total number of hours of sunlight on the day 2 Press the SUN key again will display the selected city See LOCATION SE...

Страница 19: ...r However if the icon displayed is a sun or raining cloud there will be no change of icon if the weather gets any better with sunny icon or worse with rainy icon since the icons are already at their extremes The icons displayed forecasts the weather in terms of getting better or worse and not necessarily sunny or rainy as each icon indicates For example if the current weather is cloudy and the rai...

Страница 20: ...or example from the ground floor to the upper floors of a house discard the weather forecast for the next 12 24 hours By doing this the Weather Station will not mistake the new location as being a possible change in air pressure when really it is due to the slight change of altitude WEATHER TENDENCY INDICATOR Working together with the weather icons is the weather tendency indicator located on the ...

Страница 21: ...oints 0 3 6 9 and 12 hours The 0h represents the current full hour air pressure recording The left column shows the unit in inHg 0 0 03 0 09 0 15 The 0 in the middle of this scale is equal to the current pressure and each change 0 03 0 09 0 15 represents how high or low in inHg scale the past pressure was compared to the current pressure If the bars are rising it means that the weather is getting ...

Страница 22: ...d readings for the next 12 hours DISPLAY OF INDOOR TEMPERATURE HUMIDITY DATA The indoor temperature and humidity are measured automatically and displayed on the first section of the LCD DISPLAY OF OUTDOOR TEMPERATURE HUMIDITY DATA The last section of the LCD display shows the outdoor temperature and humidity and a reception symbol Indoor temperature in F Indoor humidity in RH Outdoor temperature i...

Страница 23: ...lly Date and time of recordings will be shown for outdoor temperature data RESETTING THE MAXIMUM MINIMUM RECORDS To reset the MIN MAX records press and hold the MIN MAX key for 2 seconds This will reset ALL minimum and maximum temperature records to current readings Outdoor temperature in F Recorded MIN MAX outdoor temperature time Recorded MIN MAX outdoor temperature date ...

Страница 24: ...al operation please check the following points 1 The distance of the weather station or transmitter should be at least 5 to 6 5 feet 2 3 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning the weather station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the same ...

Страница 25: ...ing environment and interference levels If no reception is possible despite the observation of these factors all system units have to be reset see Setting up POSITIONING THE WEATHER STATION The weather station comes complete with a foldout stand that gives the option of table standing or wall mounting To wall mount 1 Fix a screw into the desired wall leaving the head extended out by about 0 2 5mm ...

Страница 26: ...d or wall mount base To wall mount 1 Secure the bracket onto a desired wall using the screws and plastic anchors 2 Clip the transmitter onto the bracket Note Before permanently fixing the transmitter wall base place all units in the desired locations to check that the outdoor temperature humidity readings are receivable In event that the signal is not received relocate the units or move them sligh...

Страница 27: ...l point of purchase for repair by a qualified engineer Opening and tampering with the unit may invalidate their guarantee Do not expose the units to extreme and sudden temperature changes this may lead to rapid changes in forecasts and readings and thereby reduce their accuracy SPECIFICATIONS Temperature measuring range Indoor 14 1ºF to 139 8ºF with 0 2ºF resolution OF L displayed if outside this ...

Страница 28: ...6 mm WARRANTY INFORMATION La Crosse Technology Ltd provides a 1 year limited warranty on this product against manufacturing defects in materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse...

Страница 29: ...o a La Crosse Technology Ltd authorized service center Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deterioration ...

Страница 30: ...OT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also have other rights specific to your State Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or inf...

Страница 31: ...acrossetechnology com support register The complete instruction manual is available at www lacrossetechnology com 9257 Le manuel d instruction complet est disponible sur www lacrossetechnology com 9257 El manual de instrucciones completo está disponible en www lacrossetechnology com 9257 ...

Страница 32: ...LOS ANGELES LAX REDDING ROD SAN DIEGO SAN SAN FRANCISCO SFO COLORADO CO DENVER DEN DURANGO DRO GRAND JUNCTION GJT PUEBLO PUB DISTRIC OF COLUMBIA DC WASHINGTON DCA FLORIDA FL JACKSONVILLE JAX MIAMI MIA ORLANDO ORL TALLAHASSEE TLH TAMPA TPA GEORGIA GA ATLANTA ATL HAWAII HI HONOLULU HNL IOWA IA DES MOINES DSM DAVENPORT DVN IDAHO ID BOISE BOI ILLINOIS IL CHICAGO ORD SPRINGFIELD SPI ...

Страница 33: ...NE ME AUGUSTA AUG CARIBOU CAR MICHIGAN MI DETROIT DET ROGERS CITY PZQ MINNESOTA MN DULUTH DLH INTERNATIONAL FALLS INL MISSOURI MO JEFFERSON CITY JEF MISSISSIPI MS JACKSON JAN MONTANA MT BILLINGS BIL HELENA HLN NORTH CAROLINA NC CHARLOTTE CLT RALEIGH RDU NORTH DAKOTA ND BISMARCH BIS FARGO FAR NEBRASKA NE LINCOLN LNK SIDNEY SNY NEW HAMPSHIRE NH CONCORD CON NEW JERSEY NJ TRENTON TTN NEW MEXICO NM ...

Страница 34: ...ORD MFR PORTLAND PDX PENNSYLVANIA PA HARRISBURG CXY PITTSBURGH PIT SCRANTON SCR SOUTH CAROLINA SC CHARLSTON CHS COLUMBIA CUB SOUTH DAKOTA SD SIOUX FALLS FSD RAPID CITY RAP TENNESSEE TN NASHVILLE BNA KNOXVILLE DKX MEMPHIS MEM TEXAS TX AMARILLO AMA AUSTIN AUS BROWNSVILLE BRO DALLAS FT WORTH DFW EL PASO ELP HOUSTON HOU ODESSA ODO SAN ANTONIO SAT UTAH UT SALT LAKE CITY SLC VIRGINIA VA LYNCHBURG LYH ...

Страница 35: ...URLINGTON BTV WASHINGTON WA SEATTLE SEA SPOKANE SFF WISCONSIN WI GREEN BAY GRB LA CROSSE LSE WEST VIRGINIA WV CHARLESTON CRW WYOMING WY CASPER CPR CA CANADA CALGARY ALB OTTAWA OTT QUEBEC QUE TORONTO TOR VANCOUVER VAN WINNEPEG WIN ...

Страница 36: ...his company could void the user s authority to operate the equipment Statement according to FCC part 15 105 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and ca...

Страница 37: ... This handbook must not be reproduced in any form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing error...

Отзывы: