GENERAL INFORMATION 

BATTERIES: WHAT DO I NEED TO KNOW ABOUT BATTERIES? 

 

Good fresh batteries are important for best performance in your sensor and as backup in 

your station. 

 

Batteries are manufactured 10 years in advance of the date on the battery.  

 

We recommend batteries with an expiration date no more than 6 years in advance of the 

current year for best performance. 

 

A minimum voltage of 1.48 v per battery is required for best performance. 

 

Lithium batteries may be used in outdoor sensor. Alkaline batteries for the station. 

HARDWARE: SENSOR AND STATION 

 

Your WS-9023U-IT station comes with: 

TX21U-IT Thermo-hygro sensor that reads Temperature and Humidity. 

Your sensor operates at 915MHz RF. 

Transmission range is 330 feet (100 meters) open air. 

 

WHAT ARE THE POWER REQUIREMENTS FOR THIS STATION? 

 

TX21U-IT: 2-AA batteries 

WS-9023U-IT: 2-AA batteries  

SETUP: HOW DO I SETUP MY STATION? 

 

1.

 

Install batteries into your sensor. 

2.

 

Install batteries into the station. 

3.

 

Let sensor and station sit within 10 feet of each other for several minutes to lock the sensor 

signals to the display. 

MOUNTING: WHERE DO I MOUNT/POSITION MY SENSOR? 

 

TX21U-IT: 

 

Place your thermo-hygro sensor at least 6 feet off the ground. 

 

For accurate temperature readings your sensor needs to be shaded from the sun in a well 

vented area. 

 

Mount your sensor vertically to allow moisture to drain out the bottom. 

 

Preferred location is on a north facing wall under an eave or deck rail. 

 

Avoid placing near a metal roof that will cause it to read high on sunny days. 

 

Avoid other sources of heat such as soffit vents, and window or door frames. 

 

For accurate humidity readings, avoid placement near vegetation and lakes or other bodies 

of water when possible. 

 

Place your sensor in a well-vented area. Trapped moisture will cause inaccurate readings. 

 

Maximum transmission distance from your thermos-hygro sensor to your station, in open air 

is 330 feet (100 meters).  

 

Содержание WS-9023U-IT

Страница 1: ...sistance Interference 3 How do I view my MIN and MAX Temperature Humidity Readings 3 How do I reset the Temperature Humidity Readings 3 How do I manually set the time 4 Does this station have 12 hour...

Страница 2: ...UP HOW DO I SETUP MY STATION 1 Install batteries into your sensor 2 Install batteries into the station 3 Let sensor and station sit within 10 feet of each other for several minutes to lock the sensor...

Страница 3: ...gnal path between the sensor and your station Simple relocation of the sensor or the station may correct an interference issue Windows can reflect the radio signal Metal will absorb the RF radio frequ...

Страница 4: ...nutes are displayed Press and release the SET button once more and you are done Note When in the 12h mode there is only a PM display which appears under the word TIME During the AM hours this area wil...

Страница 5: ...of the station and search again WHY DON T MY TEMPERATURE HUMIDITY READINGS ON MY STATION MATCH THE WEATHER REPORT Your temperature and humidity readings are from you sensor at your location Your local...

Страница 6: ...th a wall between the sensor and the station for 1 hour If there is no loss of signal in that hour move the sensor just outside Continue moving the sensor back to its original location If you lose con...

Страница 7: ...outdoor temperature area should show a temperature reading on channel 1 and on channel 2 7 When the readings appear in the outdoor temperature area channel 2 move to the third transmitter 8 Insert bat...

Отзывы: