background image

WS-8248U 

ATOMIC CLOCK WITH INDOOR TEMP/HUMIDITY AND OUTDOOR 

TEMPERATURE

 

Instruction Manual 

 

FEATURES: 

 

Hanging holes

ATOMIC CLOCK: 

Foldable stands

Battery cover

LCD1 
display 

LCD2 
display 

Function keys 

 
 
 

 

 
 
 
 
 
 

 

WWVB Radio controlled time with manual time setting 

 

Time display: hour, minute, second 

 

Alarm setting with snooze function 

 

Complete calendar display 

 

Weekday display (3 languages to choose from: English, French and Spanish) 

 

Time zone setting 

 

Daylight savings time ON/OFF option (DST) 

 

ºF or ºC temperature display selectable  

 

Indoor temperature and humidity display 

 

Outdoor temperature display via 433MHz transmission 

 

Wall mount or freestanding 

 

Current moon phase display 

 
 

 

1

Содержание WS-8248

Страница 1: ... manual time setting Time display hour minute second Alarm setting with snooze function Complete calendar display Weekday display 3 languages to choose from English French and Spanish Time zone setting Daylight savings time ON OFF option DST ºF or ºC temperature display selectable Indoor temperature and humidity display Outdoor temperature display via 433MHz transmission Wall mount or freestanding...

Страница 2: ...both units Avoid using rechargable batteries TO INSTALL AND REPLACE BATTERIES IN THE ATOMIC CLOCK The atomic clock uses 3 x AA 1 5V batteries To install and replace the batteries please follow the steps below 1 Pull down on the tab at the top of the battery cover and lift up to remove the cover 2 Insert batteries observing the correct polarity see marking inside battery compartment 3 Replace compa...

Страница 3: ...s also updated with the received time Please refer to notes on Radio controlled time and Manual time setting 4 After the time signal has been received or the search mode has been manually stopped the indoor temperature will be displayed Note When changing batteries in either of the units ensure that the batteries do not spring free from the contacts Always wait at least 15 minutes after removing t...

Страница 4: ...ature WWVB time Radio reception icon Outdoor temperature Weekday Date Alarm icon Month Moon Phase Note If the atomic clock has already successfully received the WWVB time signal and displays the correct time and date then the Manual settings can be skipped After completion of the above described procedures in Setting up the manual setting modes can be entered by pressing and holding the SET key fo...

Страница 5: ...will be displayed in the lower display and a number will flash to the right of the word LCD 3 Press and release the key to select the desired LCD contrast 4 Press and release the SET ket to confirm the LCD contrast and continue to the Time Zone setting TIME ZONE SETTING The time zone can be set between the 1 to 12 hour or Greenwich Mean Time GMT range 1 The time zone will start flashing Default se...

Страница 6: ... OFF 3 Press and release the SET key to confirm the DST setting and continue to the Radio controlled time setting Note The DST default is ON meaning that the WWVB will automatically change the time according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona and parts of Indiana turn the DST OFF RADIO CONTROLLED TIME SETTING 1 The word ON will start ...

Страница 7: ... 12 hour mode the time will be displayed with an additional PM for the time from 12 00 noon until 11 59 1 The hour digits will start flashing in the upper LCD 2 Select the desired hours by pressing and releasing the key 3 Press and release the SET key to advance to the minutes setting 4 Now the minute digits will start flashing 5 Select the desired minutes by pressing and releasing the key If the ...

Страница 8: ...tart flashing in the lower LCD 2 Press and release the key to select the desired year 3 Press and release the SET key to confirm the Year setting and continue to the Month setting MONTH SETTING 1 The month digits on LCD2 will start flashing 2 Press and release the key to select the desired month 3 Press and release the SET key to confirm the Month setting and continue to the Date setting DATE SETT...

Страница 9: ...me is set To deactivate the alarm OFF press and release once the ALM key in normal mode display The alarm icon will disappear the alarm is now off SNOOZE SETTING The snooze can only be activated during alarm time for a snooze duration of 10 minutes by pressing the SNZ key on the back of the clock OUTDOOR TEMPERATURE TRANSMITTER The temperature is measured and transmitted to the atomic clock every ...

Страница 10: ...gnal is received correctly do not re open the battery cover of either the outdoor temperature transmitter or atomic clock as the batteries may spring free from the contacts and force a false reset Should this happen accidentally then reset all units see Setting up above otherwise transmission problems may occur The maximum transmission range is 330 feet 100 meters from the outdoor temperature tran...

Страница 11: ...re of the Earth s Ionosphere reception is very limited during daylight hours The atomic clock will search for a signal every night when reception is best The WWVB radio station derives its signal from the NIST atomic clock in Boulder Colorado A team of atomic physicists continually measures every second of every day to an accuracy of ten billionths of a second a day These physicists have created a...

Страница 12: ...below 1 second Note In case the atomic clock is not able to detect the WWVB signal disturbances transmitting distance etc the time can be manually set please refer to notes on Manual time setting MOON PHASE The moon phases appear in the middle of the lower LCD There are 12 visible Moon Phases that will show in the LCD MOON PHASES FOR THE WS 8248 New Moon Small Waxing Large Waxing First Quarter Sma...

Страница 13: ... and wait approximately 10 minutes before permanently mounting to ensure that there is proper reception The outdoor temperature transmitter is not waterproof and should not be placed anywhere it will become submerged in water or be directly in the rain POSITIONING THE ATOMIC CLOCK There are two possible ways to mount the atomic clock use of the foldout table stands or wall mounting FOLDOUT TABLE S...

Страница 14: ... with the use of screws using the adhesive tape MOUNTING WITH SCREWS 1 Remove the mounting bracket from the outdoor temperature transmitter 2 Place the mounting bracket over the desired location Through the three screw holes of the bracket mark the mounting surface with a pencil 3 Where marked start the screw holes into mounting surface 4 Screw mounting bracket onto the mounting surface Ensure tha...

Страница 15: ...re section of the LCD Solution 1 Move the atomic clock to an area with warmer or cooler surrounding temperature Current surrounding temperatures are outside measuring range Problem appears in the outdoor temperature section of the LCD Solution 1 Remove the batteries of both units for one minute then reinsert them again Make sure the batteries are new and fresh 2 Move the atomic clock closer to the...

Страница 16: ...to the units Please return it to the original point of purchase Opening and tampering with the units may invalidate the warranty SPECIFICATIONS Temperature measuring range Indoor 14 1ºF to 99 8ºF with 0 2ºF resolution 9 9ºC to 37 6ºC with 0 1ºC resolution OFL displayed if outside this range Outdoor 21 8ºF to 157 8ºF with 0 2ºF resolution 29 9ºC to 69 9ºC with 0 1ºC resolution OFL displayed if outs...

Страница 17: ...ip This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service cente...

Страница 18: ... 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulti...

Страница 19: ...ny form even in excerpts or duplicated or processed using electronic mechanical or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and...