Note:

 

 

After setting up, readings for weather forecasts should be disregarded for the next 12-24 hours. This will allow sufficient time for the Weather Station to collect air pressure 
data at a constant altitude and therefore result in an more accurate forecast. 
 
Common to weather forecasting, absolute accuracy cannot be guaranteed.  The weather forecasting feature is estimated to have an accuracy level of about 75% due to the 
varying areas the Weather Station has been designed for use in.  In areas that experience sudden changes in weather (for example from sunny to rain), the Weather Station 
will be more accurate compared to use in areas where the weather is stagnant most of the time (for example mostly sunny). 
 
If the Weather Station is moved to another location significantly higher or lower than its initial standing point (for example from the ground floor to the upper floors of a house), 
remove the batteries from both the Weather Station and transmitter and re-insert them after about 30 seconds.  By doing this, the Weather Station will not mistake the new 
location as being a possible change in air-pressure when really it is due to the slight change of altitude.  Again, disregard weather forecasts for the next 12 to 24 hours as this 
will allow time for operation at a constant altitude. 

 
The weather tendency indicator 

 
Working together with the weather icons are the weather tendency indicators (located above and below the weather icons). When the indicator points upwards, it means that 
the air-pressure is increasing and the weather is expected to improve, but when indicator points downwards, the air-pressure is dropping and the weather is expected to 
become worse. 
 
Taking this into account, one can see how the weather has changed and is expected to change. For example, if the indicator is pointing downwards together with cloud and 
sun icons, then the last noticeable change in the weather was when it was sunny (the sun icon only).  Therefore, the next change in the weather will be the cloud with rain 
icons since the indicator is pointing downwards. 
 

Note:

 

 

Once the weather tendency indicator has registered a change in air pressure, it will remain permanently visualized on the LCD. 
 

Storm warning indicator: 

 
The downward tendency indicator will flash if the air pressure has dropped by 4 hPa or more in the last 6 hours. 
 

Relative air pressure inHg 
 

Underneath the weather icons is the air pressure reading which is recorded constantly in inHg and the Weather Station displays this reading as the relative air pressure. 
 

Air pressure history (electronic barometer with barometric pressure and trend)

 

 
 
 
 
 
 
 
 
 
(Each bar represents 1 hPa (millibar); 1hPa = 0.03 inHg (inches of mercury))  
 
The bar chart indicates the air pressure trend over the last 72 hours in 8 steps, 0, -1, -3, -6, -12, -24, -48 and -72 hours. The bar is plotted at each of the right (0, ±1, ±3, ±5, 
and ±7) compares the result. The “0“ in the middle of this scale is equal to the current pressure and each change (±1, ±3, ±5, and ±7) is how high or low in “hPa“ the past 
pressure was compared to the current. 
 
If the bars are rising it ,it means that the weather is getting better due to the increase of air pressure. If the bars go down, it means the air pressure has dropped and the 
weather is expected to get worse from the present time “0“. 
 

Note:   

For accurate barometric pressure trends, the Weather Station should operate at the same altitude for example, it should not be moved from the ground to the second floor of 
the house. Should the unit be moved to a new location, reset both the transmitter and Weather Station as this will prevent the slight change in lication registrering as a 
possible change in air pressure. 

 

After the resetting or setting up, weather readings should be discarded for the next 12 to 24 hours as this will allow sufficient time for the Weather Station to operate at a 
constant altitude and thus enabling a more accurate reading. 

 

Outdoor temperature reading 
 

The outdoor temperature is displayed underneath the weather icon section. The Weather Station will automatically start scanning for the transmitter’s 433MHz signal after the 
batteries are inserted and once received, the outdoor temperature will appear on the LCD. 

 
Minimum and maximum outdoor temperature readings 

 
Underneath the current outdoor temperature, are the outdoor minimum and maximum temperature recordings. When a new temperature low or high is reached, it will be 
updated and recorded into the Weather Station memory. 
 

Automatic minimum and maximum indoor andoutdoor temperature resetting 

 
The Weather Station is programmed to reset the indoor minimum and maximum temperature recordings once a day. The maximum temperatures are reset at 8:00am and the 
minimum temperatures at 8:00pm. 
 

Checking for 433MHz reception 

 
The Weather Station will automatically start scanning for the 433MHz signal after the batteries are inserted. If the outdoor temperature is not displayed after about 30 seconds, 
then check the following list before resetting the units (see 

Resetting

 below): 

 
1. 

The distance of the receiver or transmitter should be at least 1.5 to 2 meters away from any interfering sources such as computer monitors or TV sets. 

2. 

Avoid placing the receiver onto or in the immediate proximity of metal window frames. 

3. 

Using other electrical products such as headphones or speakers operating on the same signal frequency (433MHz) may prevent correct signal transmission and 
reception. 

4. 

Neighbours using electrical devices operating on the 433MHz signal frequency can also cause interference. 

Air pressure over 
the last 72 hours 

Air pressure scale 

Содержание WS-7090U

Страница 1: ...pressure inHg with adjustable reading ranges Air pressure history for the past 72 hours electronic barometer with barometric pressure and trend Current outdoor temperature display in degree Fahrenheit...

Страница 2: ...n from the slot at the base of the unit and then press and hold the SET key until the LCD5 start flashing 2 Press the key to select and go through each of the 8 different contrast tones 3 Once the des...

Страница 3: ...range between 68 F to 78 7 F and relative humidity range between 45 to 65 will register the Smilling face The Sad face will appear should either the temperature or humidity readings be outside these s...

Страница 4: ...bar chart indicates the air pressure trend over the last 72 hours in 8 steps 0 1 3 6 12 24 48 and 72 hours The bar is plotted at each of the right 0 1 3 5 and 7 compares the result The 0 in the middl...

Страница 5: ...uce or increase the transmitting range For this reason we recommend not placing the unit on any metal surfaces or in any position where a large metal surface is in the immediate proximity garage doors...

Страница 6: ...materials and workmanship This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this produc...

Страница 7: ...La Crosse Technology 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Fax 608 796 1020 e mail support lacrossetechnology com warranty work sales lacrossetechnology com information on other pro...

Отзывы: