background image

 

18

displayed, otherwise press the button twice) will display the 
same data for the maximum recordings. 

3.  To reset the Minimum/Maximum readings, it is necessary to 

select which Thermo Hygro Transmitter you wish to reset.  
Press and hold the 

OUT

 button for 5 seconds, the records for 

the selected Thermo Hygro Transmitter unit will be reset. 

 

 
 

MOUNTING 
 

Note:

  Before permanently mounting, ensure that the Indoor Temperature 

Station is able to receive WWVB signals from the desired location.  Also, 
extreme and sudden changes in temperature will decrease the accuracy of 
the weather station and changes in elevation will result with inaccurate 
weather forecasting for the next 12 to 24 hours.  These changes will require 
a 12 to 24 hour wait before obtaining reliable data. To achieve a true 
temperature reading, avoid mounting where direct sunlight can reach the 
Thermo Hygro Transmitter.  We recommend that you mount the Thermo 
Hygro Transmitter on a North-facing wall.  The sending range is 80ft—
obstacles such as walls, concrete and large metal objects can reduce the 
range.  Place both units in their desired location and wait approximately 10 
minutes before permanently mounting to ensure that there is proper 
reception.  The Indoor Weather Station should display a temperature in the 
OUTDOOR LCD within 4 minutes of setting up.   
 

I.  THERMO HYGRO TRANSMITTER 
A.  MOUNTING WITH THE SCREWS 

 
1.  Remove the mounting bracket/receptor from the packaging. 
2.  Place the mounting bracket over the desired mounting surface.  

Through the 2 screw holes of the bracket, mark the mounting surface 
with a pencil. 

3.  Where marked, start the screw holes using the provided screws.  

Remove screws from the mounting surface. 

Содержание WS-7026U

Страница 1: ...WS 7026U Wireless 433 MHz Radio Controlled Weather Station Instruction Manual...

Страница 2: ...2...

Страница 3: ...ay Date and Year 10 Selecting F or C 11 Setting the LCD Contrast 11 Features Back Light 12 Weather Forecast Icons 12 13 Indoor Temperature Humidity Comfort Level Indicator 14 Outdoor Temperature Humid...

Страница 4: ...gy Time and Frequency Division WWVB radio station is located in Ft Collins Colorado and transmits the exact time signal continuously throughout the United States at 60 kHz The signal can be received u...

Страница 5: ...eception time period of 12 00 AM to 6 00 AM 5 Mount the units ensuring that all units are sending and receiving signals Note The Thermo Hygro Transmitter transmits a signal every 3 minutes After the b...

Страница 6: ...stalled each LCD Liquid Crystal Display will flash and a tone will sound Within a few seconds the indoor temperature indoor relative humidity and the weather icons sun and clouds will be displayed If...

Страница 7: ...corresponding to the operation that you want to perform II 12 OR 24 HOUR TIME SETTING 1 Press and hold the SET button for 3 seconds or until 12 h flashes in the DATE LCD 2 Press the CH button to toggl...

Страница 8: ...Time setting IV DAYLIGHT SAVING TIME DST SETTING 1 Press and hold the SET button for 3 seconds or until 12 h or 24 h flashes in the DATE LCD 2 Press the SET button 2 more times to reach the DST selec...

Страница 9: ...is in progress will remain steady when the signal has been received and nothing will be displayed in all other situations If the WWVB time has not been received after 10 minutes of battery installatio...

Страница 10: ...e automatically set once the WWVB signal is received However the day date and year can be manually set and will flash respectively in the DATE LCD during manual programming 3 The weekday will be flash...

Страница 11: ...II SETTING THE LCD CONTRAST 1 Press and hold the SET button for 3 seconds or until 12h or 24h flashes in the DATE LCD 2 Press the SET button 10 more times to reach the LCD contrast setting mode 3 The...

Страница 12: ...automatically shutting off II WEATHER FORECAST The weather forecasting feature is estimated to be 75 accurate The weather forecast is based solely upon the change of air pressure over time The WS 702...

Страница 13: ...irectly to rainy although it is possible for the change to occur quickly If the symbols do not change then the weather has not changed or the change has been slow and gradual B WEATHER TENDENCY ARROWS...

Страница 14: ...ture is explained in further detail in section VI Adding Outdoor Thermo Hygro Transmitters V MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS 7026U keeps a record of the MINIMUM and MAXIMUM temperature...

Страница 15: ...d date of occurrence are displayed 3 While MAX is still displayed press the OUT button again to return to the current data display Or you can wait 20 seconds during either the minimum or the maximum r...

Страница 16: ...directions above for alarm 1 using the AL2 button instead of the AL1 button The 2 icon will represent activation and deactivation of alarm 2 B SNOOZING AND STOPPING THE ALARM 1 The snooze function is...

Страница 17: ...overs to all Remote Transmitter units 3 Place all Remote Transmitter units in a numeric sequential order 4 In sequential order install batteries follow the same battery installation procedures seen in...

Страница 18: ...taining reliable data To achieve a true temperature reading avoid mounting where direct sunlight can reach the Thermo Hygro Transmitter We recommend that you mount the Thermo Hygro Transmitter on a No...

Страница 19: ...d The mounting surface should be smooth and flat 2 Remove the protective strip from one side of the tape Press firmly onto the designated area on the back of the mounting bracket 3 Remove the protecti...

Страница 20: ...priate location B WALL MOUNTING 1 Remove the table stand To do this pull down on the stand from the rear and rotate forward 2 Fix a screw not included into the desired wall leaving approximately 3 16...

Страница 21: ...4 If there are still problems contact La Crosse Technology Problem Hour is incorrect minute and date are correct Solution Be sure correct time zone and daylight saving time are selected Problem The L...

Страница 22: ...displays and units with a soft damp cloth Do not use solvents or scouring agents They may mark the displays and casings Do not submerge in water Immediately remove all low powered batteries to avoid l...

Страница 23: ...interval Every 10 seconds Indoor Humidity checking interval Every 1 minute Outdoor Temperature and Humidity checking interval Thermo Hygro Transmitter Every 1 minute Outdoor Temperature and humidity...

Страница 24: ...OGY WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS WEATHER STATION THIS PRODUCT IS NOT TO BE USED FOR MED...

Страница 25: ...VICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED IN...

Отзывы: