background image

 

 

6. 

Operation using cable connection or wireless 433MHz 

7. LCD 

Overview 

 

 

Cable Connection: 

The following illustration shows the full segments of the LCD for 
description purposes only and will not appear like this during normal 
operation and use. 

Using this method of operation will provide interference free transfer of the 
weather data from the sensors to the base station.  The data sending interval 
from the sensors to the base station will also be more frequent compared to 
using 433MHz transmission and will result in higher power consumption.  
Therefore batteries will have a shorter life span for cable connection compared 
to using 433MHz.  To operate using cable connection, simply use the enclosed 
32ft cable and connect the thermo-hygro sensor to the base station.  Once the 
connection is detected, the base station will automatically continue reading the 
data from the sensor. 

 
 
 
 
 
 
 

 

 

The user may at any time switch from cable connection to using 433MHz (or 
vice versa) by simply disconnecting (or connecting) the cable from the base 
station to the sensor.  When the base station detects no cable connection to 
the sensors, the base station will automatically change to using 433 MHz for 
reception of the weather data from the sensors. 

 
 
 
 
 

 

 

The data receiving intervals are as follows: 

 

Using cable connection data is updated every 8 seconds. 

 

Using wireless 433 MHz data is updated from 16 to 128 second intervals 
depending on wind speed and rain activity. 

 
 

 

 

Using the AC adaptor to operate the base station will also supply power to the 
sensor if the cable is connected to it.  Batteries used for 433MHz transmission 
may be left in the sensor when using cable connection for power back up in 
case of AC power failure.  A loss of power would desynchronize the base 
station and the sensor and no weather data will be received.  To synchronize 
the units so that the weather data can be received, press and hold the PLUS 
(+) key for 2 seconds.  However in general, batteries that will not be used for 
long periods should be removed to avoid leakage.   

 
 
 
 
 
 

15.  24h, 1h or total hour display 
16.  Humidity display as RH% 
17.  Rainfall units (inch or mm) 
18.  Temperature display units (ºC or ºF) 
19. Outdoor temperature/humidity display 
20.  Indoor temperature/humidity display 
21.  Dew point temperature display 
22.  Wind chill temperature display 
23.  Wind alarm icon 
24.  Wind information for Min/Max speed 

and wind speed low, high, direction 
alarm 

25.  Wind direction and speed (m/s, knots, 

Beaufort, km/h or mph) display  

26.  Alarm buzzer ON/OFF icon 
27. General alarm icon 

1.  Low battery indicator 
2.  WWVB radio controlled time icon 
3. Date 

display 

4.  Time zone display 
5.  Date, seconds, alarm time and time 

zone 

6. Alarm 

icon 

7.  Weather forecast icons 
8.  Weather tendency indicator 
9.  Pressure alarm display 
10.  hPa/inHg air pressure unit 
11.  Pressure units (relative or absolute) 
12.  433MHz reception icon 
13. Rainfall display 
14.  Indoor, outdoor, humidity, dew point, 

wind chill, rainfall alarm icon 

 

 
 

 

 

Wireless 433MHz transmission: 

 

16

26

25

24

18

21

22

20

19

11

17

15

10

13

14

23

27

12

6

7

5

4

3

2

Using 433MHz wireless transmission of weather data from the sensor to the 
base station will provide users greater freedom as to where units can be 
positioned without the need to be restricted by cable. 

 
 
 

 

 

Note: 

 

If no outdoor weather data is displayed or the signal to the sensors is lost 
during setting up, mounting, changing of batteries to the sensor or plugging or 
unplugging cables, simply press and hold the PLUS (+) key for 2 seconds and 
a short beep will sound to synchronize the base station to sensors.  Without 
being synchronized, weather data will not be received. 

 
 
 
 
 

Содержание WS-2315CH

Страница 1: ...Function test 11 9 Mounting 12 10 Resetting factory settings 14 11 Function description 16 12 Operation keys 19 Using the enclosed 6 5ft computer cable and CD ROM you can install the Heavy Weather software to your PC and access the latest weather information from your PC and upload up to 175 sets of recorded weather data received by the base station Recorded data can be used to generate statistics...

Страница 2: ...unit Wind chill temperature display Inserting batteries in an incorrect polarity will cause damage to this product Dew point temperature display Weather forecast display by weather icons sunny cloudy rainy This product is not a toy Keep out of the reach of children Weather tendency indicator Do not dispose of new or used batteries in a fire as they may explosion or release dangerous chemicals Stor...

Страница 3: ...ction cover 32ft cable optional connection to the base station included Wall mounting screws Plastic anchors for screws Wind Sensor Main unit with wind vane 32ft cable already attached to the main unit Mast holder 2 x U bolts for mast holder 4 x Washers 4 x Nuts 1 x screw to fix main unit to the mast holder Rain Sensor Main unit base and funnel 32ft cable already attached to the main unit Heavy we...

Страница 4: ...e is transmitted and this code must be synchronized with the base station to receive weather data When the base station is powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code After the learning mode or by pressing the MIN MAX key at anytime the base station will start the WWVB r...

Страница 5: ... failure A loss of power would desynchronize the base station and the sensor and no weather data will be received To synchronize the units so that the weather data can be received press and hold the PLUS key for 2 seconds However in general batteries that will not be used for long periods should be removed to avoid leakage 15 24h 1h or total hour display 16 Humidity display as RH 17 Rainfall units...

Страница 6: ...played in the respective weather sections of the LCD In this case check that all cables are correctly inserted into the correct sockets and or check the batteries in the outdoor thermo hygro sensor and press and hold the PLUS key for 2 seconds and a short beep will sound to synchronize the base station to the sensors otherwise no weather data will be received Mounting the Wind Sensor onto a mast W...

Страница 7: ...section MIN MAX Mode below An ideal mounting place for the thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws to affix the wall bracket to the desired wall plug in the thermo hygro sensor to the bracket and secure both parts by the use of the supplied sc...

Страница 8: ...ure threshold 0 09 inHg LCD contrast level 5 1 8 levels Rainfall per impulse 0 0204 inches Storm alarm 0 09 inHg Relative air pressure alarm 28 34 inHg low 30 71 inHg high Indoor temperature alarm 50ºF low 86ºF high Outdoor temperature alarm 32ºF low 104ºF high Indoor humidity alarm 35 RH low 65 RH high Outdoor humidity alarm 45 RH low 70 RH high Wind chill alarm 50ºF low 86ºF high Dew point alarm...

Страница 9: ...wpoint below freezing the fallout will become frost or snow Air Pressure LCD Section 1 The air pressure reading is displayed here Press the PRESSURE key to toggle between relative and absolute air pressure displays Windchill has been introduced for battle planning during World War II It represents not the real measured but the temperature a person feels in open area under the influence of wind and...

Страница 10: ...al WIND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm programming mode In alarm programming mode to select the following setting modes Time alarm setting Indoor temperature alarm high low Outdoor temperature alarm high low Indoor humidity alarm high low Outdoor humidity alarm high low Outdoor win...

Страница 11: ...re max or min with time and date 9 Air pressure display in hPa or inHg default setting inHg Outdoor humidity max or min with time and date 10 Relative air pressure setting from 27 10 inHg 31 90 inHg default 29 98 inHg Outdoor wind chill max or min with time and date 11 Weather forecast sensitivity setting 6 9 12 inHg default setting 9 inHg 12 Storm warning sensitivity setting 9 12 15 18 21 24 29 i...

Страница 12: ...e digits will start flashing and set the desired indoor temperature low by using the PLUS or MINUS keys 2 Indoor temperature high alarm and low alarm 3 Outdoor temperature high alarm and low alarm 4 Indoor humidity high alarm and low alarm 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to another alarm setting mode 5 ...

Страница 13: ... and press the MIN MAX key to return to the normal display mode or press the ALARM key once more to toggle to the wind chill low alarm set mode 5 Press and hold the SET key to enter the wind chill low setting values digits will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode o...

Страница 14: ...ng mode Storm warning alarm setting Unlike the other weather alarms the storm warning alarm is set by entering the main manual setting mode as follows 1 Press the SET key to enter the manual setting mode 2 Continue to press the SET key until the Storm warning icon flashes tendency arrow flashing downwards with the pressure values flashing 3 Set the desired inHg pressure value 9 12 15 18 21 24 27 i...

Страница 15: ...old LCD contrast Alarm time Weather Alarm thresholds State of alarms enabled disabled Rainfall total value and reset time date 17 Accessories adding cable extensions For your convenience additional telephone cables to increase the connection distance between each of the units may be purchased from any reputable hardware store Simply add these to the current cables to extend your cable connection d...

Страница 16: ...e connected extension heads away from rain moisture and other extreme weather conditions as exposure can cause short circuits and damage to this item 18 Changing batteries Battery change only in the thermo hygro sensor 1 Open the battery cover 2 Remove the old batteries and insert with new ones of the recommended type and replace the cover Once the sensor is powered up press and hold the PLUS key ...

Страница 17: ...Resolution Letter format 21 Cleaning and Maintenance Using 433MHz wireless data transmission Clean the housing and screen of the base station only with a soft damp cloth Do not use abrasives or solvents Measuring interval thermo hygro sensor 32 sec if wind factor 22 36 mph or 128sec if wind factor Ensure that the rain sensor does not collect leaves or other dirt by checking the funnel for blockage...

Страница 18: ... covered by this warranty Before sending the Weather Station in for repairs contact La Crosse Technology The Weather Station will be repaired or replaced with the same or similar model This warranty does not cover any defects resulting from improper use unauthorized repairs faulty batteries or the Weather Stations inability to receive a signal due to any source of interference LA CROSSE TECHNOLOGY...