background image

Ideally the sensor should be at least 6 feet off the ground (higher is fine) for best signal transmission.

Place the thermo-hygro sensor in a well-shaded area that is protected from direct sun. The sensor will read high if exposed to the sun.
A good location is under the eaves on the north side of the house. A small roof or box may be constructed for it if you do not have an
overhang.

The cap on the thermo-hygro sensor is for proper airflow for humidity reading and 

not

 rain protection. The thermo-hygro sensor can

withstand rain, snow and temperature extremes. Standing rain and snow may soak into the sensor and cause failure. Take care to
ensure that it will not be exposed to a downpour. Light incidental exposure to water typically will not harm the sensor.

Note:

 Plug the wind sensor cable into the thermo-hygro sensor 

before 

installing batteries. 

RAIN GAUGE:

 The Rain gauge transmits directly to the indoor weather station. When considering the distance from the weather station (330 feet open air), 

cut that distance in half for each wall, window, tree, bush or other obstruction in the signal path.  Closer is better. Material such as stucco or metal will absorb 
a wireless signal. Windows can reflect the signal. 

AVOID:

 Mounting too tight. Do not screw the rain gauge down too tight. That will result in a low or inaccurate reading. Use just 2 screws, snug not tight. 

Install the Rain gauge on a level platform that is stationary.  If the gauge isn't level it will read low, and if it isn't stationary wind will cause it to read rain
that isn't falling.

The Rain sensor should be mounted at least 6 ft. in the air and have a direct line of sight to the weather station.

Do not place the rain gauge extremely high as the rain gauge should be accessible to allow for periodic cleaning of debris or
insects.

The Rain Gauge is self-emptying and can be left out all year or stored in the winter. If stored for the winter, remove
the batteries to avoid leakage. Be aware of other wireless rain gauges in the area that may cause interference.

SPECIFICATIONS 

  WARRANTY 

WS-1913U-IT:

 

5.83" x 5.83" x 2.0" 

 

(192.53 L x 163.83 W x 249.94 H mm) 

 

 

TX31U-IT:

 

2.44"L x 2.25"W x 6.18"H 

 

Thermo-Hygro

 

(61.97 L x 57.2 W x 156.97 H mm)

  

 

 

 

 

2 “AA” batteries (not included) 

 

 

 

TX23U-IT Wind

:  

7.58"L x 6.45"W x 9.84"H 
(148 x 148 x 50.8mm) 
2 “C” batteries (not included) 
Powered by thermo-hygro sensor 

Optional Rain Gauge: 
TX32U-IT 

 

5.51"L x 2.75"W x 5.39"H 
(139.95L x 69.85 W x 136.91 H mm) 
2 “AAA” batteries (not included)

 

 

 

 

 

 
 

 
 

 
 

 
 
 

 
 
 

 
 
 
 
 

 

 

 

FCC DISCLAIMER 

This device complies with part 15 of the FCC rules.  
Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference. 
(2) This device must accept any interference received, 
including interference that may cause undesired operation. 

All rights reserved.  This handbook must not be reproduced in any form, 
even in excerpts, or duplicated or processed using electronic, 
mechanical or chemical procedures without written permission of the 
publisher. 

This handbook may contain mistakes and printing errors.  The 
information in this handbook is regularly checked and corrections made 
in the next issue.  We accept no liability for technical mistakes or printing 
errors, or their consequences. All trademarks and patents are 
acknowledged. 

Contact Support: 1-608-782-1610 

  

La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing 
defects in materials and workmanship. 

This limited warranty begins on the original date of purchase, is valid only on products purchased and 
used in North America and only to the original purchaser of this product.  To receive warranty service, 
the purchaser must contact La Crosse Technology, Ltd for problem determination and service 
procedures.  Warranty service can only be performed by a La Crosse Technology, Ltd authorized 
service center.  The original dated bill of sale must be presented upon request as proof of purchase to 
La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. 

La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as 
stipulated herein, with new or reconditioned parts or products if found to be defective during the 
limited warranty period specified above.  All replaced parts and products become the property of La 
Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd.  Replacement parts and 
products assume the remaining original warranty, or ninety (90) days, whichever is longer.  La Crosse 
Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty.  
If necessary repairs are not covered by this warranty, or if a product is examined which is not in need 
or repair, you will be charged for the repairs or examination.  The owner must pay any shipping 
charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd 
authorized service center.  La Crosse Technology, Ltd will pay ground return shipping charges to the 
owner of the product to a USA address only. 

Your La Crosse Technology, Ltd warranty covers all defects in material and workmanship with the 
following specified exceptions: (1) damage caused by accident, unreasonable use or neglect 
(including the lack of reasonable and necessary maintenance); (2) damage occurring during shipment 
(claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or 
decorative surface; (4) damage resulting from failure to follow instructions contained in your owner’s 
manual; (5) damage resulting from the performance of repairs or alterations by someone other than an 
authorized La Crosse Technology, Ltd authorized service center; (6) units used for other than home 
use (7) applications and uses that this product was not intended or (8) the products inability to receive 
a signal due to any source of interference..  This warranty covers only actual defects within the 
product itself, and does not cover the cost of installation or removal from a fixed installation, normal 
set-up or adjustments, claims based on misrepresentation by the seller or performance variations 
resulting from installation-related circumstances. 

LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, 
CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE 
OPERATION OR MALFUNCTION OF THIS PRODUCT.  THIS PRODUCT IS NOT TO BE USED 
FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION.  THIS PRODUCT IS NOT A TOY.  
KEEP OUT OF CHILDREN’S REACH. 

This warranty gives you specific legal rights.  You may also have other rights specific to your State.  
Some States do not allow the exclusion of consequential or incidental damages therefore the above 
exclusion of limitation may not apply to you. 

For warranty work, contact: 

La Crosse Technology, Ltd 

2817 Losey Blvd. S. 

La Crosse, WI 54601 

Temperature measuring range: 

Indoor: 

32° F to +139.8° (0º C to +59.9º C) 
(Displays “OF.L” if outside this range) 

Outdoor / dew point: 

-40° F to +139.8°F (-40º C to +59.9º C) 
(Displays “OF.L” if outside this range) 

Relative humidity measuring range: 

Outdoor: 

1% to 99% with 1% resolution 
(Displays “- -” if < 1%, "99" Displays if 

 99%) 

Wind speed/ gust:

 

0 to 111.8 mph (0 to 180km/h; 0 to 50 m/s)  
(Displays "OF.L" when > 111.8 mph; 180 km/h;  
50m/s) 

Wind chill/ dew point:

-40°F to +139.8° F (-40ºC to +59.9º C) 
(“OF.L” displayed if outside this range) 

Relative pressure range:

    27.14 to 31.90 inHg (919 to 1080 hPa) 

24h rainfall:

 

 0’ to 39.3" (0 to 999.9 mm) 

Total rainfall:

 

0" to 393.7" (0 to 9999 mm)  
(Displays "OF.L" when > 9999mm) 

Outdoor data reception:

 Every 4.5 seconds (from thermo-hygro 

transmitter) 
Every 6.25 seconds (from rain gauge-optional) 

Air pressure interval:

 Every 15 seconds 

Transmission range:

  Up to 330 feet (100 meters) in open space 