background image

 

 

Quartz clock in 12 or 24-hour time display (hour and minute, manually set) 

 

Indoor and outdoor temperature reading in degrees Fahrenheit (°F) or Celsius (

°

C) 

 

Display of MIN/MAX records of indoor temperature and outdoor temperature 

 

Can receive up to three outdoor transmitters 

 

Wireless transmission at 915 MHz 

 

Signal reception intervals at 4 seconds 

 

Low battery indicator 

 

Wall mounting or table standing (foldout table stand)

 

 

The Outdoor Temperature Transmitter 

 

Remote transmission of outdoor temperature to Temperature 
Station by 915 MHz 

 

Rain resistant casing 

 

Wall mounting case (Mounting at a sheltered place. Avoid direct 
rain and sunshine)

 

 
 
 
 
 
 
 

 

SETTING UP: 

 

When one transmitter is used: 

1. 

First, insert the batteries into the transmitter (see “

How to install and replace batteries in the 

Temperature transmitter

” below). 

2. 

Within 30 seconds of powering up the transmitter, insert the batteries to the Temperature Station (see 

How to install and replace batteries in the Temperature Station

” below). Once the batteries are in 

place, all segments of the LCD will light up briefly. Then the indoor temperature and the time as 12:00 will 
be displayed. If they are not shown on LCD after 60 seconds, remove the batteries and wait for at least 
60

 

seconds before reinserting them. Once the indoor data is displayed, user may proceed to the next 

step. 

3. 

After the batteries are inserted, the Temperature Station will start receiving data signal from the 
transmitter. 

4. 

The outdoor temperature should be displayed on the Temperature Station. Also, the signal reception icon 
will be displayed. If this does not happen after 2 minutes, the batteries will need to be removed from both 
units and reset from step 1. 

5. 

In order to ensure sufficient 915 MHz transmission, the final position between the Temperature Station 
and the transmitter should not be more than 330 feet / 100 meters (see notes on 

“Positioning”

 and 

“915 

MHz Reception”

). 

6. 

Batteries are the #1 warranty issue we see. Please be sure you are using name brand plain alkaline 
batteries dated at least 7 years in advance or testing to 1.48 on a voltmeter that reads in numbers. 

 

 

When more than one transmitter is used 

1. 

User shall remove all the batteries from the Temperature Station and transmitters and wait 
60 seconds if setting has been done with one transmitter first.   

2. 

Insert the batteries to the first transmitter. 

3. 

Within 30 seconds of powering up the first transmitter, insert the batteries to the 
Temperature Station. Once the batteries are in place, all segments of the LCD will light up 
briefly. Following time as 12:00 will be displayed. If the time is not shown in LCD after 60 
seconds, remove the batteries and wait for at least 60 seconds before reinserting them.  

4. 

The outdoor temperature from the first transmitter (channel 1) should then be displayed on 
the Temperature Station. Also, the signal reception icon will be displayed. If this does not 
happen after 2 minutes, the batteries will need to be removed from both units and reset 
from step 1. 

5. 

Insert the batteries to the second transmitter as soon as the outdoor temperature readings 
from the first transmitter are displayed on the Temperature Station.   

 

Note:

  User shall insert the batteries into the second transmitter within 10 seconds of reception 

of the first transmitter. 
 

 

6. 

The outdoor temperature from the second transmitter and the "channel 2" icon should 
then be displayed on the Temperature Station. If this does not happen after 2 minute, the 
batteries will need to be removed from all the units and reset from step 1. 

7. 

Insert the batteries to the third transmitter as soon as the "channel 2" icon and outdoor 
temperature data is displayed on the Temperature Station. Then within 2 minutes, the 
channel 3 outdoor data from the third transmitter will be displayed and the channel icon 
will shift back to "1" once the third transmitter is successfully received. If this is not 
happen, user shall restart the setting up from step 1.  

 

Note:

  User shall insert the batteries into the third transmitter within 10 seconds of reception of 

the second transmitter. 

 

8. 

In order to ensure sufficient 915 MHz transmission there should be no more than 330 
feet (100 meters) between the final position of the Temperature Station and the 
transmitter (see notes on “

Mounting

” and “

915 MHz Reception

”). 

 

Note: 

If the signal reception is not successful on the first frequency (915MHz) for 40 seconds, the 
frequency is changed to 920MHz and the learning is tried another 40 seconds. If still not 

Содержание Wireless Temperature Station

Страница 1: ...ifications 32 Warranty Information 33 3 INVENTORY OF CONTENTS 1 Wireless Temperature Station 2 Wireless Outdoor Temperature Transmitter TX29U IT and mounting bracket 3 Instruction Manual This product offers INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update ...

Страница 2: ...ter is used 1 User shall remove all the batteries from the Temperature Station and transmitters and wait 60 seconds if setting has been done with one transmitter first 2 Insert the batteries to the first transmitter 3 Within 30 seconds of powering up the first transmitter insert the batteries to the Temperature Station Once the batteries are in place all segments of the LCD will light up briefly F...

Страница 3: ...few minutes of power supplying HOW TO INSTALL AND REPLACE BATTERIES IN THE TEMPERATURE STATION The Temperature Station uses 2 x AAA IEC LR3 1 5V batteries When batteries will need to be replaced the low battery icon will appear on the LCD To install and replace the batteries please follow the steps below 1 Lift up the battery compartment cover 2 Insert batteries observing the correct polarity see ...

Страница 4: ...TEMPERATURE UNIT C F SETTING To display the time in 12 hour or 24 hour mode default setting 12h 1 In normal display mode press and hold the SET key for about 3 seconds The 12h or 24h digit will be flashing 2 Press the key to set the desired time display mode 3 Press shortly the SET key to advance to the MANUAL TIME SETTING Note When the time display is set as 12 hour mode the temperature unit will...

Страница 5: ...lease check the following points 1 The distance of the Temperature Station or transmitter should be at least 5 to 6 5 feet 1 5 to 2 meters away from any interfering sources such as computer monitors or TV sets 2 Avoid positioning the Temperature Station onto or in the immediate proximity of metal window frames 3 Using other electrical products such as headphones or speakers operating on the same s...

Страница 6: ...er wall base place all units in the desired locations to check that the outdoor temperature reading is receivable In event that the signal is not received relocate the transmitter s or move them slightly as this may help the signal reception CARE AND MAINTENANCE Extreme temperatures vibration and shock should be avoided as these may cause damage to the unit and give inaccurate forecasts and readin...

Страница 7: ...pping charges to the owner of the product to a USA address only Your La Crosse Technology Ltd warranty covers all defects in material and workmanship with the following specified exceptions 1 damage caused by accident unreasonable use or neglect including the lack of reasonable and necessary maintenance 2 damage occurring during shipment claims must be presented to the carrier 3 damage to or deter...

Страница 8: ...or chemical procedures without written permission of the publisher This handbook may contain mistakes and printing errors The information in this handbook is regularly checked and corrections made in the next issue We accept no liability for technical mistakes or printing errors or their consequences All trademarks and patents are acknowledged ...

Отзывы: