Topic Page 

     Inventory of Contents/ Additional Equipment 

     About WWVB 

     Quick Set Up Guide 

Detailed Set Up Guide 

 

     Battery Installation 

     Start Up Sequence 

     Explanation of LCD Information 

     Function Key Layout 

Program Mode 

 

     Overview of Programming Sequence 

     LCD Contrast Setting 

     Time Zone Setting 

     DST ON/OFF Setting 

     Radio-controlled Time ON/OFF Setting 

9-10 

     12/24-hour Time Mode Setting 

10 

     Setting the Time/Date Manually 

10-11 

     Temperature Measuring Units (ºF/ºC) 

12 

     Air Pressure Measuring Units (inHg/hPa) 

12 

     Relative Pressure Setting 

12 

     

Forecast Sensitivity Setting 

13 

Features and Operation 

 

     Minimum/Maximum Temperature/Humidity 

14 

     Multiple Remote Temperature/Humidity Sensors 

15-16 

     Comfort Icon 

16 

     Weather Forecast and Pressure Trend Indicators 

16 

     Weather Icons 

16-17 

     Weather Tendency Arrows 

17 

     Barometric Air Pressure Reading 

17 

     Air Pressure History Bar Chart 

17-18 

Mounting 

19-20 

Maintenance and Care 

20 

Troubleshooting Guide 

21 

Specifications 

22 

Warranty Information 

23-24 

 
 
 
 
 
 
 
 
 

Содержание Tomorrow's Weather Today WS-7394U-IT

Страница 1: ...WS 7394U IT Wireless 915 MHz Wireless Weather Station Instruction Manual ...

Страница 2: ... Mode Setting 10 Setting the Time Date Manually 10 11 Temperature Measuring Units ºF ºC 12 Air Pressure Measuring Units inHg hPa 12 Relative Pressure Setting 12 Forecast Sensitivity Setting 13 Features and Operation Minimum Maximum Temperature Humidity 14 Multiple Remote Temperature Humidity Sensors 15 16 Comfort Icon 16 Weather Forecast and Pressure Trend Indicators 16 Weather Icons 16 17 Weather...

Страница 3: ...on WWVB is located in Ft Collins Colorado and transmits the exact time signal continuously throughout the United States at 60 kHz The signal can be received up to 2 000 miles away through the internal INSTANT TRANSMISSION is the state of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY INSTANT TRANSMISSION offers you an immediate update every ...

Страница 4: ...reless Weather Station does not display both temperatures after the 15 minutes please retry the set up as stated above After both indoor and outdoor temperatures are displayed for 15 minutes you can place your remote temperature sensor outdoor and set your time The remote temperature sensor should be placed in a dry shaded area The temperature sensor has a range of 330 feet Keep in mind that the 3...

Страница 5: ...d then be displayed on the Weather Station If this does not happen after 2 minutes the batteries will need to be removed from both units and reset from step 1 and the signal reception icon is no longer shown A Remote Temperature Sensor 1 Remove the mounting bracket The bracket snaps on and off easily 2 Remove the battery cover by sliding the cover down 3 Observing the correct polarity install 2 AA...

Страница 6: ...door weather station is looking for signals from the remote temperature sensor Within five minutes the remote temperature should be displayed if not remove batteries from all units and repeat battery installation the remote temperature sensor first then the indoor weather station B WWVB Reception 1 Once the batteries are installed in the Wireless Weather Station it will automatically search for th...

Страница 7: ...in the past 24 hours the reception indicator will be displayed After a successful reception no more reception attempt would be made until the following day III Explanation of LCD Information A The below picture highlights the LCD features Radio controlled time WWVB Reception Indicator Date Display Comfort Icon Indoor Temperature Humidity Display Air Pressure Trend Indicator Forecast Icon Barometri...

Страница 8: ...Complete programming is usually done for the initial set up and will require you to skip step 1 2 and 3 of each programming section The programming mode can be exited at any time by either pressing the CH button or waiting for the 15 second time out to take effect A Overview of programming mode sequence 1 LCD Contrast 2 Time Zone 3 DST ON OFF 4 Radio controlled Time ON OFF 5 12 24 hour time mode 6...

Страница 9: ...ss and hold the SET button for five seconds 2 lcd will appear at the top of the display and a number will flash next to it 3 Press and release the SET button twice more to advance to the DST ON OFF setting 4 DST will appear above the indoor temperature humidity display and ON or OFF will flash above that 5 Press and release the OUT button to select DST ON OFF Note Some locations Arizona and parts ...

Страница 10: ...Note In 12h mode PM will appear to the left of the time during PM hours If the time is not within the PM hours nothing will be displayed Be sure to set the time to the correct AM PM time to ensure automatic reception 6 Press and release the SET button to confirm the 12 24 hour time mode setting and continue to the Hour setting G Setting The Hour Manually The WWVB signal will override any manual se...

Страница 11: ...n more times to advance to the Manual Year setting 4 The year will begin to flash below the time display 5 Press and release the OUT button to select the desired year 6 Press and release the SET button to confirm the year and continue to the Month setting J Setting The Month Manually 1 Press and hold the SET button for five seconds 2 lcd will appear at the top of the display and a number will flas...

Страница 12: ... select the desired temperature measuring unit 6 Press and release the SET button to confirm the temperature measuring unit and continue to the Air Pressure Measuring Units setting M Air Pressure Measuring Units Selection inHg hPa 1 Press and hold the SET button for five seconds 2 lcd will appear at the top of the display and a number will flash next to it 3 Press and release the SET button eleven...

Страница 13: ...o the Forecast sensitivity setting 4 The two air pressure tendency arrows will begin flashing on either side of the forecast icon and a flashing number will appear under the forecast icon 5 Press and release the OUT button to select the desired forecast sensitivity setting Note Barometric air pressure is usually reported as relative air pressure This reading is based on the combination of absolute...

Страница 14: ... fifteen seconds Note To reset the indoor minimum and maximum temperature and humidity first display the values you wish to reset minimum or maximum Next press and hold the SET key for at least three seconds You will see then that the values will reset to the current temperature and humidity and corresponding time 2 Outdoor Minimum and Maximum Temperature The indoor weather station automatically s...

Страница 15: ...wn after 2 minutes the batteries will need to be removed from both units and reset from step 1 5 Insert the batteries to the second sensor as soon as the outdoor temperature readings from the first sensor are displayed on the Weather Station NOTE You must insert the batteries into the second sensor within 10 seconds of reception of the first sensor 6 The outdoor temperature from the second sensor ...

Страница 16: ...g feature is estimated to be 75 accurate and is based solely upon the change of air pressure over time The WS 7394U IT averages past air pressure readings to provide an accurate forecast creating a necessity to disregard all weather forecasting for 12 24 hours after the unit has been set up reset or moved from one altitude to another i e from one floor of a building to another floor In areas where...

Страница 17: ...ure is decreasing and the weather is expected to become worse or remain poor G Barometric Air Pressure Reading 1 The actual barometric air pressure is displayed directly under the weather forecast icon 2 The relative air pressure is calibrated by the user through the programming mode 3 Please Follow the programming instructions in section F of the Detailed Set Up Guide to set this feature H Air Pr...

Страница 18: ...les such as walls concrete and large metal objects can reduce the range Place all units in their desired location and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception If the Wireless Weather Station loses the signal from the remote sensor it will display the last temperature reading for 15 minutes After 15 minutes of not receiving any signals the r...

Страница 19: ...able stand on the wall with the use of a wall hanging screw not included 1 USING THE TABLE STAND The indoor weather station comes with the table stand already mounted If you wish to use the table stand all that is required is to place the indoor weather station in an appropriate location 2 WALL MOUNTING a Remove the table stand To do this pull down on the stand from the rear and rotate forward b F...

Страница 20: ...eck Replace batteries 2 If multiple remote sensors are in use check location with corresponding boxed numbers 3 Move away from sources of heat cold 4 Adjust relative air pressure to a value from a reliable source TV radio etc 5 The indoor weather station and remote sensors are calibrated at the factory If there is a consistent problem please call La Crosse Technology Problem in humidity display So...

Страница 21: ...on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty service the purchaser must contact La Crosse Technology Ltd for problem determination and service procedures Warranty service can only be performed by a La Crosse Technology Ltd authorized service center The original dated bill of sal...

Страница 22: ...tallation related circumstances LA CROSSE TECHNOLOGY LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL CONSEQUENTIAL PUNITIVE OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION THIS PRODUCT IS NOT A TOY KEEP OUT OF CHILDREN S REACH This warranty gives you specific legal rights You may also h...

Страница 23: ...d to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communication...

Отзывы: