La Crosse Technology K86319 Скачать руководство пользователя страница 12

12 

 

SPECIFICATIONS:

 

Indoor

Temperature Range:  

 

+32° F to +122°F (0° C to + 50° C) 

Humidity Range: 

 

1%-99% (RH) 

Interval:  

 

 

Every 30 seconds 

 
Outdoor

Temperature Range:  

 

-40°F to 140°F (-40°C to 50°C) 

 

Use Alkaline batteries in outdoor sensor: -20°F to 140°F (-20°C to 60°C) 

 

Switch to Lithium batteries in outdoor sensor if temperature drops below - 20°F (-28.8°C) 

 
Humidity Range: 

 

1%-99% (RH) 

Distance: 

 

 

200 ft. (60 meters) RF 433MHz (open air) 

Interval:  

 

 

Every 50 seconds 

 
Power: 

Forecast Station

 

5-volt a/c power adapter (included) 
Optional 3-AA, IEC, LR6 batteries (not included) 

TX14TH Transmitter: 

 

2-AA, IEC, LR6 batteries (included) 

 

Battery Life

  

 

TX14TH Transmitter 
Battery Life:  

 

Battery life is over 24 months when using reputable battery brands for both  
Alkaline and Lithium batteries 

  

Forecast Station

 

Battery Backup:    

Battery life is over 24 months when using the AC adapter for primary power 

 

Dimensions: 

Forecast Station

:  

   

5.9” L x 2.36” W x 5.9” H (150 x 60 x 150mm) 

TX14TH Transmitter:      

2.5” L x 1.42” W x 3.98” H (64 x 36 x 101mm)

 

 
ACCURACY: 
Indoor Temperature: 

  Operating temperature range =  

32 F to 122 F (0C to 50C)    

  Accuracy ± 2 degrees Fahrenheit  

32 F to 122 F (0C to 50C) 

  Resolution = 0.1 degree F  
  When above 122 F (50C) the temperature sensor should continue to read the correct temperature as 

long as the LCD Forecast Station continues to function 

  When below 32 F (0C) the temperature sensor should continue to read correctly as long as the LCD 

Forecast Station continues to function 

 

Indoor Humidity: 

 

Operating Temperature Range =  

32F to 120F (0C to 50C) 

 

Operating humidity range =   

1% RH to 99% 

 

Ac/- 5% RH (@77

o

F (25

o

C) , 30%RH to 80%RH) 

 

Ac/- 8% RH (@77

o

F (25

o

C)  , 20%RH to29%RH & 80%RH to 95%RH) 

 

Ac/-12% RH (@77

o

F (25

o

C)  , 1%RH to 19%RH & 96%RH to 99%RH)   

 

Resolution = 1 % RH  

 

Outdoor Temperature: 

  Operating temperature range =  

-40 F to 140F (-40C to 60C)    

  Accuracy ± 2 degrees Fahrenheit  

32 F to 122 F (0C to 50C) 

  Accuracy ±4 degrees Fahrenheit  

-40 F to32 F (-40C to 0C) & 122 F to140 F (50C to 60C)

 

  Resolution = 1 degree F  
  When above 140 F (60C) the temperature sensor should continue to read the correct temperature as 

long as the LCD Forecast Station continues to function 

  When  below  -40F  (-40C)  the  temperature  sensor  should  Forecast  Station  continue  to read  correctly 

as long as the LCD Forecast Station continues to function  

 
 

Содержание K86319

Страница 1: ...eks for barometer calibration to generate an accurate forecast Wireless Color Forecast Station OUTDOOR TEMPERATURE HUMIDITY TRANSMITTER TX14TH Wireless Color Forecast Station Model K86319 Time Date We...

Страница 2: ...TIVATE ALARM 6 SNOOZE 6 BACKLIGHT 8 A C ADAPTER 8 BATTERIES 8 WEATHER FORECAST ICONS 8 LCD SCREEN 9 MIN MAX TEMPERATURE HUMIDITY DATA 9 VIEW 9 RESET 9 HEAT INDEX 10 DEW POINT 10 OUTDOOR TEMPERATURE HU...

Страница 3: ...Station see Power the Forecast Station The Forecast Station will light up and show indoor temperature humidity and channel 1 2 Insert 2 fresh AA batteries into the transmitter observing the correct p...

Страница 4: ...remove adapter and batteries and wait for at least 60 seconds before repeating the setup process INSTALL BATTERIES IN THE OUTDOOR TRANSMITTER 1 Slide the battery cover down then lift off the back of...

Страница 5: ...time Turn continuous backlight ON or OFF a c adapter LIGHT SNOOZE top Activates backlight when using only batteries Trigger snooze alarm PROGRAM MENU The SET button will moves through the items in the...

Страница 6: ...tton once to switch from Fahrenheit to Celsius ALARM SET Hold the ALARM button for 5 seconds to enter the alarm time set mode 1 The alarm hour digit will flash 2 Press and release the or C F button to...

Страница 7: ...tly forecasted we cannot be responsible for any loss caused by an incorrect forecast THIS STATION LEARNS Please allow 3 4 weeks for barometer calibration to generate an accurate forecast IMPORTANT As...

Страница 8: ...iew maximum temperature and humidity values for Indoor and Outdoor data The word MAX will appear next to the indoor and outdoor temperature MIN From a normal display press and release the MIN MAX butt...

Страница 9: ...mperature is the absolute measure of the moisture in the air at a given temperature Relative humidity is the relative measure of moisture in the air at a certain temperature Note Dew Point is lower th...

Страница 10: ...each sensor 10 After 15 minutes place the remote transmitters in appropriate locations see position the outdoor transmitter Press and release the CH button to view channel 1 2 or 3 on the Forecast Sta...

Страница 11: ...ew not included into a wall leaving approximately inch 12 7mm extended 3 Place the transmitter onto the screw using the hanging hole on the backside 4 Gently pull the transmitter down to lock the scre...

Страница 12: ...rature range 32 F to 122 F 0C to 50C Accuracy 2 degrees Fahrenheit 32 F to 122 F 0C to 50C Resolution 0 1 degree F When above 122 F 50C the temperature sensor should continue to read the correct tempe...

Страница 13: ...the repairs or examination The owner must pay any shipping charges incurred in getting the La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology...

Страница 14: ...ce that may cause undesired operation NOTE THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT SUCH MODIFICATIONS COULD VOID THE...

Отзывы: