background image

10 | 

P a g e

 

 

 

Pressure: InHg / hPa 

 

Pressure number setting 

 

THANK YOU 

  

Note: Units in the settings menu reflect how sensors will show on the station and which units 

are shown in Data Stream. This includes the Extra sensors. I.E. When Fahrenheit is selected-

Fahrenheit on station and in Data Stream. 

 

Settings Menu 

1.

 

Hold the SET button for 2 seconds to enter setting mode. HELLO, will show for two seconds, 

then automatically move to language. ENGLISH will show. Press the + or - button to change 

to another language (Español, or Français). Press the SET button to select Beep ON/OFF. 

2.

 

BEEP ON will show. Press the + or – button to turn beep sound OFF. Press the SET button to 

move to 12/24 hour time. 

3.

 

12/24 FORMAT will show. 12HR flashes. Press the + or - button to turn select 24 hour time 

format. 

4.

 

Press SET to confirm and move to the hour. HOUR will show. The hour flashes. Press the + 

or - button to choose the hour. 

5.

 

Press SET to confirm and move to the minutes. MINUTES will show. Minutes flash. Press the 

+ or - button to choose the minutes. 

6.

 

Press SET to confirm and move to the year. The YEAR 2020 will show. Year will flash. Press 

the + or - button to change the year. 

7.

 

Press SET to confirm and move to the month. The MONTH will show. The Month will flash. 

Press the + or - button to change the month. 

8.

 

Press SET to confirm and move to the date. DATE will show. Date will flash. Press the + or - 

button to change the date. 

9.

 

Press SET to confirm and select Month/Date or Date/Month display. The MONTH/DATE will 

show. Press the + or - button to select DATE/MONTH. 

10.

 

Press SET to confirm and move to the temperature unit. TEMP °C Celsius will show. ̊C will 

flash. Press the + or - button if you prefer °F (FAHRENHEIT). 

11.

 

Press SET to confirm and move to pressure units. PRESSURE will show. INHG will flash. 

Press the + or - button to select HPA. 

12.

 

Press SET to confirm and move to adjust pressure number. PRESSURE will show. Pressure 

number will flash. Press the + or - button to adjust pressure number. 

13.

 

Press SET to confirm. THANK YOU shows for 2 seconds, then exit the setting menu. 

Note: After 10 seconds with no button press, station returns to normal time display. 

OTHER WEATHER STATION FEATURES 

BACKLIGHT: DOES THIS STATION HAVE A BACKLIGHT? 

 

Yes, your station has a backlight with 5 levels of intensity.  

 

Press and release the LIGHT button to adjust the backlight intensity or to turn it off. 

 

Intensity levels: 0% (OFF) | 1.5% | 20% | 50% | 100% 

 

Содержание CA79103

Страница 1: ...station 4 MOUNTING Where do I mount position my sensors 4 Where to I place my station 5 What is Distance Resistance Interference 5 WEATHER STATION READINGS 5 What is this EXTRA SENSOR Area 5 How do I...

Страница 2: ...Accuweather HI LO Temperatures 14 Custom Data Streams 14 TROUBLESHOOTING 15 BAR CODE What are the barcodes and ID Numbers on my sensors on my station 15 How do I delete sensor ID numbers 15 FACTORY RE...

Страница 3: ...your router s separate 2 4GHz Wi Fi network and that you ve correctly entered your Wi Fi password For more troubleshooting tips and support visit www lacrossetechnology com lacrosseviewsupport BATTERI...

Страница 4: ...NT POSITION MY SENSORS LTV TH2i 1 Use the hole at the top to hang your sensor from the back using a nail Or insert one mounting screw through the front of your sensor 2 Mount your sensor on a north fa...

Страница 5: ...the signal path from your station to each sensor as a straight line Consider the distance the station is from other electronics in the home Resistance Each obstacle walls windows vegetation stucco con...

Страница 6: ...seconds then return to normal display 4 Scan sensor bar code ID so it will read in the La Crosse View app 5 Added sensors will be available for display in Extra Sensor area of station HOW DO I DELETE...

Страница 7: ...dity readings are reset individually 1 Press and release the TEMP button to view the reading you wish to reset 2 Hold the MINUS button for 5 seconds to reset individual temperature or humidity value t...

Страница 8: ...s a LO or HI alert Press any button to stop the temp alert sound The alert icon will flash while value is in alert range 1 Press and hold the ALERTS button 2s to enter alert set mode 2 Press and relea...

Страница 9: ...TIME DOES THIS STATION HAVE ATOMIC TIME Standalone station When operating as a standalone station the time needs to be set manually on this station Connected to the La Crosse View app When operating a...

Страница 10: ...Year will flash Press the or button to change the year 7 Press SET to confirm and move to the month The MONTH will show The Month will flash Press the or button to change the month 8 Press SET to con...

Страница 11: ...is required for your sensors to update When you operate as a connected station the 5 volt power cord is required to maintain Wi Fi connection and sensor updates BATTERY WHAT DO THE BATTERY ICONS MEAN...

Страница 12: ...ssure based on its location over time to generate an accurate personal forecast Please allow 7 10 days for barometer calibration Note As the Station builds memory it will compare the current average p...

Страница 13: ...use o Enter your Wi Fi password again o Check your network connection o Hold the and buttons together for 3 seconds to search for Wi Fi NO WEATHER SERVICE o Wi Fi and App are fine o Weather Time serv...

Страница 14: ...ng Wait a few minutes and try again ACCUWEATHER HOURLY FORECAST Press the HOURLY button on the side of your station to scroll through 12 hours of future forecasts You ll see hourly changes in Changing...

Страница 15: ...the sensor readings are from your sensor and not a neighbors When you press and release your SENSOR button you will see your Station ID your Thermo Hygro sensor ID your Water Leak sensor ID Note If y...

Страница 16: ...readings will differ WHAT DOES A READING OF HI OR LO MEAN If your outdoor temperature reading shows HI or LO check that your batteries are good Overpowered or underpowered batteries can cause this rea...

Страница 17: ...unication may come and go occasionally This can be normal in some environments e g moister climates If a sensor goes out please wait 2 4 hours for it to reconnect on its own Please be patient these st...

Страница 18: ...DINGS ON MY STATION DIFFERENT FROM THE SENSOR READINGS IN THE APP The reading on your station is the real time reading Your station updates as soon as it receives a new reading from the sensor The App...

Отзывы: