background image

 

 

  P a g e

| 28  

explosives. The batteries shall be taken out from the unit before the product is to be stored for a long 
period of time. 

 

Immediately remove all low powered batteries to avoid leakage and damage. Replace only with new 
batteries of the recommended type. 

 

When cleaning the display and casings, use a soft damp cloth only. Do not use solvents or scouring 
agents as they may mark the LCD and casings. 

 

Do not submerge the unit in water. 

 

Special care shall be taken when handling a damaged LCD display. The liquid crystals can be 
harmful to user's health. 

 

Do not make any repair attempts to the unit. Return them to their original point of purchase for repair 
by a qualified engineer. Opening and tampering with the unit may invalidate their guarantee.  

 

Never touch the exposed electronic circuit of the device. There is a danger of electric shock should it 
become exposed. 

 

Do not expose the display to extreme and sudden temperature changes, this may lead to rapid 
changes in forecasts and readings and thereby reduce their accuracy. 

 

ALERT  AND MONIT ORING DISCLAIMER 

* Disclaimers: La Crosse Technology, LTD. (“La Crosse”) provides various alert and monitoring services 
to aid users. (1) Service providers may charge users for alert services. Standard messaging and data 
rates apply and will be billed to the customer’s wireless account.  Customers may be unable to receive 
text messaging or data service in some areas due to unavailability of service. (2) La Crosse shall not be 
liable for accuracy, usefulness or availability of data transmitted via the service. Users are solely 
responsible for damages to persons or property by service use. 
 

LIABILIT Y DISCLAIMER 

 

 

The electrical and electronic wastes contain hazardous substances. Disposal of electronic waste in 
wild country and/or in unauthorized grounds strongly damages the environment. 

 

Please contact the local or/and regional authorities to retrieve the addresses of legal dumping 
grounds with selective collection. 

 

All electronic instruments must from now on be recycled. User shall take an active part in the reuse, 
recycling and recovery of the electrical and electronic waste. 

 

The unrestricted disposal of electronic waste may do harm on public health and the quality of 
environment. 

 

As stated on the gift box and labeled on the product, reading the “User manual” is highly 
recommended for the benefit of the user. This product should not be thrown in general rubbish 
collection points. 

 

The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any 
consequences that occur should an inaccurate reading take place. 

 

This product is designed for use in the home only as indication of the temperature. 

 

This product is not to be used for medical purposes or for public information. 

 

The specifications of this product may change without prior notice. 

 

This product is not a toy. Keep out of the reach of children. 

 

No part of this manual may be reproduced without written authorization of the manufacturer. 

 

FCC ST AT EMENT 

 
Statement according to FCC part 15.19: 

This device complies with part 15 of the FCC rules.  Operation is subject to the following two conditions: 

 

This device may not cause harmful interference. 

 

This device must accept any interference received, including interference that may cause undesired 
operation. 

Statement according to FCC part 15.21: 

Modifications not expressly approved by this company could void the user's authority to operate the 
equipment. 
 

Содержание C84612

Страница 1: ...C84612 Wireless Professional Weather Center Hardware Manual...

Страница 2: ...ng is done on www lacrossealerts com with an account that you create if you wish to use these added features Online information at www lacrossetechnology com c84612 TABLE OF CONTENTS INTRODUCTION 2 IN...

Страница 3: ...rm 17 Wind direction alarm 17 24 Hour rainfall alarm 17 HYSTERESIS 17 DISPLAY MODES 18 Mode 1 18 Mode 2 18 Date or seconds display 18 Rainfall Display 18 WEATHER FORECAST AND TENDENCY 18 Weather forec...

Страница 4: ...speed gust 26 Wind chill 26 Rainfall 26 Outdoor data reception Interval 26 Air pressure 26 Transmission range 27 Power consumption 27 Weather Center 27 Thermo hygro transmitter 27 Rain sensor 27 Wind...

Страница 5: ...atent 6 761 065 RE42 057 Remote Monitoring Alerts Account Activation Card Remote Monitoring Text E mail Alerts IMPORTANT Do Not Discard Card Contains the Activation Key to enable remote monitoring and...

Страница 6: ...ime date 0 to 111 mph km h m s knots Beaufort scale Wind direction with compass 16 points 22 5 degrees Wind gust with max time date Rainfall for last hour 24hr week month total 0 to 393 7 inches 0 to...

Страница 7: ...luded Remote Monitoring Text Email Alerts Optional Remotely monitor home backyard weather from your smartphone tablet or computer Outdoor temperature humidity Wind rain Barometric pressure Indoor temp...

Страница 8: ...ation with the correct polarity Note Every time the wireless weather station receives data from the sensors the wireless icons will blink once and then return to solid if the last transmission was suc...

Страница 9: ...ATE BUTTON Press to toggle between the display of seconds or date in the time display Press to increase the level of different settings in SET mode Hold to re learn the thermo hygro sensor synchroniza...

Страница 10: ...SET button to advance to the next SET mode item LCD contrast setting Air pressure unit setting Manual time setting Relative pressure reference value setting 12 24 hour time display Weather tendency th...

Страница 11: ...set manually by following the steps below 1 The year digit will flash Press the DATE button or RAIN button to set the year The range runs from 00 2000 to 99 2099 2 Press the SET button to confirm the...

Страница 12: ...ure value will flash 2 Press the DATE button or RAIN button to increase or decrease the value Continually holding the button will allow the value to increase faster 3 Press the SET button to confirm a...

Страница 13: ...r the remote monitoring registration information only from the weather station 1 rES oFF will flash 2 Use the DATE button or RAIN button to select rES Lo 3 Press the SET button to confirm and the weat...

Страница 14: ...rm i e temperatures 14 F won t trigger alarm but temperatures 104 F will When the value meets the condition for high alarm or low alarm the alarm will ring for 2 minutes and the value will blink along...

Страница 15: ...the indoor temperature alarms INDOOR TEMPERATURE ALARMS 1 The high indoor temperature alarm display will show 2 Press and hold the SET button for about 2 seconds The temperature digit will flash 3 Pr...

Страница 16: ...Press and hold the SET button for about 2 seconds The temperature digit will flash 8 Press the DATE button or RAIN button to set the low outdoor temp alarm value Hold the arrow button in to change th...

Страница 17: ...larm setting for a wind direction press the SET button again to remove the selected wind direction alarm The arrow icon inside the compass circle will disappear 6 If more than one wind direction is de...

Страница 18: ...larm has been switched off by a button press The flashing value indicates that the current weather condition is out of the pre set weather alarm limit s DISPLAY MODES MODE 1 Press and release the SET...

Страница 19: ...curacy cannot be guaranteed The weather forecasting feature is estimated to have an accuracy level of about 75 due to the varying areas the Weather Station has been designed for use 75 accuracy is com...

Страница 20: ...are rising from left to right this indicates that the weather is getting better due to an increase in air pressure If the bars are falling from left to right this indicates that the weather is expect...

Страница 21: ...l Rainfall value Press the DATE button The total rainfall amount will be reset to 0 and the time updated to current time MIN MAX WEATHER DATA The weather station will automatically record the maximum...

Страница 22: ...m a sustained wind MOUNTING AND PLACEMENT OF SENSORS AND DISPLAY IMPORTANT Ensure that all of the sensor data can be received at the intended mounting locations before you drill mounting holes The out...

Страница 23: ...adaptor to mount the wind sensor on a horizontal mast or surface Fasten the wind sensor to a suitable mast using the U bolt washers and nuts included Note Mount the wind sensor onto a mast at a minimu...

Страница 24: ...e THERMO HYGRO SENSOR The thermo hygro sensor is weather resistant but not waterproof To ensure an extended life for the sensor mount it in a semi covered place out of the elements at a minimum height...

Страница 25: ...dware may not work with your gateway Note Network cables usually have length limitations The same length limitations will apply that apply to computers on your home network STAND ALONE WEATHER STATION...

Страница 26: ...nge OUTDOOR HUMIDITY 3 to 99 displayed if 1 99 displayed if 99 WIND SPEED GUST 0 to 111 8 mph with resolution of 0 22 mph 0 to 180 km h with resolution of 0 36 km h 0 to 12 bft 0 to 97 1 knots with re...

Страница 27: ...panels maintain operation in every season GATEWAY 20 volt A C power cord DIMENSIONS WEATHER CENTER 8 665 L x 1 594 W x 6 795 H 220 1 x 40 5 x 172 6 mm THERMO HYGRO TRANSMITTER 3 13 L x 3 54 W x 7 45...

Страница 28: ...vice use LIABILITY DISCLAIMER The electrical and electronic wastes contain hazardous substances Disposal of electronic waste in wild country and or in unauthorized grounds strongly damages the environ...

Страница 29: ...d warranty period specified above All replaced parts and products become the property of La Crosse Technology Ltd and must be returned to La Crosse Technology Ltd Replacement parts and products assume...

Страница 30: ...ial or incidental damages therefore the above exclusion of limitation may not apply to you For warranty work technical support or information contact La Crosse Technology Ltd 2817 Losey Blvd S La Cros...

Отзывы: