Indoor

Specifications

  

Temperature Range:

  

  

Humidity Range: 

 

 

  

Update Interval:  

 

32

˚

F to 122

˚

F (0

˚

C to 50

˚

C) 

10% RH to 99%RH

About every 60 seconds

Thermo-hygro Sensor

  

Temperature Range:

  

  

Humidity Range: 

 

 

  

Update Interval: 

  Transmission 

Range: 

 

-40

˚

F to 140

˚

F (-40

˚

C to 60

˚

C) 

10% RH to 99%RH

About every 51 seconds (3 minutes if no change)

Up to 400 feet (121 meters) in open air,  RF 915 MHz 

Wind Speed Sensor

  

Wind Speed Range:

  

  

Update Interval: 

  Transmission 

Range: 

 

0-111 mph (0-178 kmh)

About every 31.5 seconds (3 minutes if no change)

Up to 400 feet (121 meters) in open air,  RF 915 MHz 

Rain Sensor

  

Rainfall Range:

  

  

Update Interval: 

  Transmission 

Range: 

 

0-393.6 inches ( 0-9999 mm) 

About every 45 seconds (3 minutes if no change)

Up to 400 feet (121 meters) in open air,  RF 915 MHz 

Wi-Fi

  

Transmission Range:

 

80 feet (24 meters) RF 2.4 GHz  

Содержание C84428

Страница 1: ...r ID s on station match bar codes on your sensors Batteries operation only will not update sensor or Wi Fi data Power cord is required Option 1 Connected with La Crosse View Benefits o Remotely monito...

Страница 2: ...Speed History Reset Wind Speed History Rainfall Readings Reset Rainfall Readings HI LO Temperature Humidity Readings Reset HI LO Temperature Humidity Readings Feels Like Temperature Temperature Humid...

Страница 3: ...ecurity this app will only work on protected WiFi networks Open public networks that require a browser sign in should not be used The Wi Fi for your mobile device must be on the same network as your w...

Страница 4: ...n choose to turn this feature off within La Crosse View NWS WIND DIRECTION MPH WIND SPEED NWS FORECAST LO HI FEELS LIKE TOP SPEED 1 HR Benefits of Your La Crosse View Select Your Own Data Streams Use...

Страница 5: ...this error Time will update from your weather station NO NWS SERVER This indicates and error on the NWS server The NWS will resolve this Very rare to have this error Your Station has Status Messages Y...

Страница 6: ...so it locks onto your rain sensor 5 Place the top portion on the sensor and lock the tabs Mounting 1 Mount in an open area for a more accurate rain count 2 Install the Rain sensor on a level platform...

Страница 7: ...batteries into your bonus station according to polarity Mounting 1 Place you bonus station on a desk or counter top 2 Use the mounting hole on the back to place your station on a wall Note the bonus s...

Страница 8: ...he RAIN button to view rainfall history to display Other readings will disappear temporarily Your station will stay on your selection NOW Rain readings from the start of a rain event until no rain has...

Страница 9: ...ate Indoor LO Humidity with Time Date Feels Like HI with time and date stamp Feels Like LO with time and date stamp Outdoor Dew Point OUTDOOR OUTDOOR Reset HI LO Temperature Humidity Records 1 Press t...

Страница 10: ...Winter June 21st Sept 20th Sept 21st Dec 20th Dec 21st Mar 19th Backlight 5 levels Your station has 5 levels of brightness for the backlight When operating with the AC adapter press and release the LI...

Страница 11: ...every 3 minutes Wind 0 5 mph 0 8 km every 31 5 seconds every 3 minutes Temp Humidity 0 9F 0 5 C every 50 seconds every 3 minutes Example It does not rain everyday When it is not raining the rain senso...

Страница 12: ...o La Crosse View 1 Bring your add on sensor close to station 2 Insert batteries into sensor 3 Open your La Crosse View app and select ADD DEVICES Press the button to add the sensor device 4 Scan the b...

Страница 13: ...elease the LIGHT button any time to exit settings Settings menu order 1 BEEP ON OFF 2 12h 24h hour format 3 Hour 4 Minutes 5 Year 6 Month 7 Date 8 Temperature Fahrenheit Celsius Factory Reset C84428 A...

Страница 14: ...a Crosse View and will need to be set manually 1 Hold the SET IN OUT button for 3 seconds to enter setting menu 2 Press and release the SEARCH button to adjust settings Hold to adjust quickly 3 Press...

Страница 15: ...F to 122 F 0 C to 50 C 10 RH to 99 RH About every 60 seconds Thermo hygro Sensor Temperature Range Humidity Range Update Interval Transmission Range 40 F to 140 F 40 C to 60 C 10 RH to 99 RH About eve...

Страница 16: ...C84428 Station LTV TH2 LTV W1 LTV R2 Sensors LTV D1 Bonus Station 48 60 months with power cord use over 24 months with reputable batteries over 12 months with reputable batteries Dimensions C84428 Sta...

Страница 17: ...View full warranty details online at www lacrossetechnology com warranty_info_lt Warranty and Support Do not mix old and new batteries Do not mix Alkaline Standard Lithium or Rechargeable Batteries A...

Страница 18: ...ng in conjunction with any other antenna or transmitter Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interfer...

Отзывы: