47
Note:
The discharging current is always set to be half of the coming charging current
whose upper limit is 700 mA (see Table 2). Therefore user is recommended to carefully
select the discharging current so that the charging current afterward will not be too high.
Table 2. DISCHARGE MODE Current
User-selected Discharging
current
100 mA
250 mA
350 mA
Thereafter Charging
current
200 mA
500 mA
700 mA
Finally batteries will be fully charged in discharge mode and “Full” will be displayed. If user
presses DISPLAY key at this time, "charge" icon instead of "discharge" icon will be displayed.
REFRESH MODE
Old rechargeable batteries and those have not been used for a long time require refreshing.
This process will recover the optimum capacity of the rechargeable batteries. By pressing
the MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode
can be selected.