background image

 

Note:

   

z

 

User shall always observe the recommended maximum charging current of the 
rechargeable batteries. In general, 200 mA is a recommended charging current if 
rapid charging is not necessary. It is definitely safe and optimum to the rechargeable 
batteries.  

z

 

It may be necessary to charge and discharge the new rechargeable batteries for 
several times in the beginning before the optimum capacity of the rechargeable 
batteries can be obtained. And user is recommended to adopt once the "Refresh" 
mode to the new rechargeable batteries in order to achieve the optimum battery 
capacity. 

z

 

When the transformer has been plugged to the power source, the version number of 
the charger (for example “29” ) will be displayed first. Then all the segments will light 
up momentarily and the “null” sign will be shown before batteries are placed. If 
damaged batteries are placed to the charging unit, the charger will also show “null” on 
LCD. 

 
 
 
 
 

 

“null” displayed - No battery or damaged 
battery is placed to the charging unit 

 

10 

START CHARGING THE RECHARGEABLE BATTERIES

 

Once a rechargeable battery is inserted after the transformer has been plugged to the power 
source, the battery voltage (for example, “1.39V”) will be displayed for 4 seconds. Then “200 
mA Charge” (default mode) will be shown on LCD for another 4 seconds, indicating that 
charging with 200 mA is to be started if no alternation in setting is made.   

Within this 8-second time from inserting the batteries the user may first select the 
operating mode by the MODE key. Press and hold the MODE button for 5 seconds.

 

Then within 8 seconds from the last key pressing, user may select the charging/ 
discharging current by pressing the CURRENT key. 

   

Note:

   

 

The mode key shall first be pressed and held for about 5 seconds to activate the 
mode change. The subsequent pressing of the mode key will enable to toggle 
between the “Charge”, “Discharge”, “Test” and “Refresh” mode. 

 

There is a 8-second time allowed for choosing further functions after each key 
pressing. If no more key is pressed, the LCD will blink one time to indicate the end of 
setting. Afterward, the current can no longer be changed during the process and the 
selected mode will be undergone.   

 
   

 

11 

 
 
 
 

 

 

During charging, the different displays- Charging current (in mA), Time elapsed (in hh:mm), 
Terminal voltage (in V) and Accumulated capacities (in mAh or Ah) may be toggled and 
selected by pressing the DISPLAY key (refer Table 4).

 

After the rechargeable battery is fully charged, “Full” sign will be shown on the display and 
the user may take them out at this time. Or if the rechargeable batteries are kept placed in 
the compartments, trickle charging will start. The trickle charging current is around 5% of the 
selected charging current to keep the rechargeable batteries full. 

 
 
 
 
 

“Full” sign is shown -The 
battery is fully charged 

Charging current: 200 mA 

Charge Mode 

After 8 seconds from no more keys 
pressing, the LCD will blink once to 
indicate the setting is confirmed and 
the selected mode activated   

 

12 

Note :   

z

 

The current cannot be altered once the setting has been confirmed in the initial stage. 
Therefore, the user can avoid changing the current setting accidentally while setting 
up other rechargeable batteries. If one wants to change the applied current afterward, 
the rechargeable batteries must be taken out and inserted again.   

z

 

The maximum charging current of other rechargeable batteries is restricted by the 
current setting of the first inserted rechargeable battery. For instance, if the first 
inserted rechargeable battery is set to charge at 500 mA, then the second, third and 
fourth rechargeable batteries can be only set to charging at a maximum current of 500 
mA.  
Therefore, the user is recommended to place the battery with the highest expected 
charging current in Compartment 1 first. To release the restriction of setting charging 
current, user shall take out all four rechargeable batteries from the charging unit.     

z

 

To change the operating mode during charging, one can press the MODE key (for 
selecting all rechargeable batteries) or NUMBER key then MODE key (for selecting 
an individual rechargeable battery). 8 seconds after the last key is pressed the LCD 
will blink one time to indicate the end of changing. 

z

 

When overheating condition occurs (usually due to too high of a charging current 
selected), the charging will be stopped immediately and the display will shown “000 
mA”, the charging process will only resume once the temperature of the rechargeable 

Содержание Battery Charger

Страница 1: ...ideal for use in the home office or on journey INVENTORY OF CONTENTS 1 Charging unit 2 Transformer 3 Instruction Manual The Charging unit 4 CAUTIONS 1 The charger is restricted to charging NiCd and Ni...

Страница 2: ...ted capacities in mAh or Ah during the charging or discharging process To change the display content of a particular rechargeable battery first press corresponding NUMBER key then press the DISPLAY ke...

Страница 3: ...the process and the selected mode will be undergone 11 During charging the different displays Charging current in mA Time elapsed in hh mm Terminal voltage in V and Accumulated capacities in mAh or A...

Страница 4: ...resses DISPLAY key at this time charge icon instead of discharge icon will be displayed REFRESH MODE Old rechargeable batteries and those have not been used for a long time require refreshing This pro...

Страница 5: ...eries to maintain the fully charged level This mode is automatically launched after rechargeable batteries are fully charged and kept at the charging unit The signal Full will be displayed on the LCD...

Страница 6: ...00 mA to charge up the battery once the power source is back to normal regardless of the operating mode Charge Discharge Refresh or Test which has been selected by user before CARE AND MAINTENANCE z E...

Страница 7: ...ge to or deterioration of any accessory or decorative surface 4 damage resulting from failure to follow instructions contained in your owner s manual 5 damage resulting from the performance of repairs...

Страница 8: ...ver time It is not recommended to condition batteries until after they have bee charged and used 10 times As you use your batteries they will gain greater capacity and last longer It is common for you...

Отзывы: