background image

La Crosse Technology, Ltd.                     www.lacrossetechnology.com/support 

Page 2 

 

Daylight Saving Time .............................................................................................................. 9 

No WWVB Tower Icon ............................................................................................................ 9 

Projection alarm is dim ........................................................................................................... 9 

Projection alarm has distorted or frozen display ....................................................................10 

Projection alarm is blank: No letters, numbers or dashed lines ..............................................10 

Projection alarm drains batteries quickly ................................................................................10 

Projection alarm has missing segments .................................................................................10 

 

  Projection Alarm Factory Restart 

 

Explanation:

 The factory restart returns the projection alarm and outdoor sensor to an “out-of-the-box” 

state and often resolves an issue.  
  

Factory Restart: 

1.  Remove all power (batteries and AC) from outdoor sensor and projection alarm.  
2.  Press one of the buttons on the projection alarm at least 20 times to clear all memory.  
3.  Verify that the projection alarm is blank before proceeding (some lines are painted on the screen and 

will show with batteries out). 

4. 

Leave unpowered for 15 minutes

 (very important). 

5.  Insert the AC cord into the wall outlet then into the projection alarm.  
6.  Insert fresh batteries into the outdoor sensor. 
7.  Press the TX button on the outdoor sensor to transmit RF signal.   
8.  Keep the outdoor sensor 5-10 feet from the projection alarm. 
9.  When RF connection is established, the temperature will appear on the station. Allow the outdoor 

sensor and projection alarm to sit together for 15 minutes to establish a strong connection.  

10.  Do not press buttons for 15 minutes. 

 

  For optimum 433MHz transmission, place the outdoor sensor no more than 200 feet (60 meters, open 

air) from the projection alarm. 

  See the section on 

mounting

 an

distance/resistance/interference 

for details on mounting the outdoor 

sensor. 

 

Outdoor Temperature Sensor 

 

Compatible Outdoor Sensors 

 

  The TX141-v2 outdoor sensor comes packaged with this projection alarm.  

  The TX141-v2 and TX141, TX14 (433MHz) outdoor sensors are compatible with this projection alarm.  

 

Quick Connect 

 

Explanation:

 The quick connect is used for a projection alarm and outdoor sensor that have been 

working but lost connection due to interference or low batteries. This is not a thorough factory reset. 

 

1. 

Bring the outdoor sensor and projection alarm together inside and place the units 5-10 feet apart 
with nothing between them.  

2. 

Hold the 

+/TEMP

 

button on the projection alarm. The outdoor temperature area will flash. 

3. 

Remove battery cover from the outdoor sensor and press and release the TX button to send the 
signal. 

4. 

Wait for 2 minutes for the outdoor temperature to appear on the projection alarm. 

 

 

Factory Restart: 

If the above procedure does not work, please try the factory reset. 

 

 
 
 

Содержание 616-146v2

Страница 1: ...ng 3 Intermittent Outdoor Temperature 3 Outdoor Temperature is stuck or HH H LL L 4 Outdoor sensor drains batteries quickly 4 Outdoor sensor fell The sensor no longer works 4 Mounting Positioning Outd...

Страница 2: ...established the temperature will appear on the station Allow the outdoor sensor and projection alarm to sit together for 15 minutes to establish a strong connection 10 Do not press buttons for 15 minu...

Страница 3: ...can cause loss of connection between the outdoor sensor and the projection alarm Turn the projection alarm 90 degrees towards the outdoor sensor to provide better reception This allows more antenna s...

Страница 4: ...etween the outdoor sensor and projection alarm Outdoor sensors at the end of the range may work while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage th...

Страница 5: ...hten Position Projection Alarm The projection alarm has a wide base to sit on a desk or table Place within range of the outdoor sensor The maximum transmitting range in open air is 200 feet 60 meters...

Страница 6: ...oor Temperature Explanation These symbols are error messages indication the indoor sensor is outside of its readable range For indoor readings this is generally a power related issue Batteries may be...

Страница 7: ...NG TIME DST will flash and the word ON Press and release the TEMP or TIME button to turn this to OFF if you do not observe DST Confirm with the SET F C button and move to the next item 4 12 24 HOUR TI...

Страница 8: ...harge your device Most USB cables included with mobile devices will work for charging Note Many devices may require more power to charge than provided by this forecast station Projection not working W...

Страница 9: ...of the clock in your home and atmospheric interference it may take up to 5 nights for the change from Daylight Savings Time to Standard Time and vice versa to occur Check for a WWVB Tower Icon showing...

Страница 10: ...ection alarm is blank No letters numbers or dashed lines Check that the batteries are installed correctly Batteries may be overpowered or underpowered Remove batteries from projection alarm Press any...

Отзывы: