9.  When RF connection is established, the temperature will appear on the station. Allow the 

outdoor sensor and wireless thermometer to sit together for 15 minutes to establish a strong 
connection.  

10. Do not press buttons for 15 minutes. 

 

  For optimum 433MHz transmission, place the outdoor sensor no more than 300 feet (91 

meters, open air) from the wireless thermometer. 

  See the section on 

mounting

 and 

distance/resistance/interference 

for details on mounting 

the outdoor sensor. 

 

Outdoor Temperature Transmitter 

 

Compatible Outdoor Transmitters 

 

  A TX141v2 outdoor transmitter comes packaged with this Digital Atomic Clock.  

  The TX141 and TX14 (433MHz) transmitters are compatible with this Digital Atomic Clock.  

 

Fahrenheit/Celsius 

 

 

Digital Atomic Clock

: Press and release the °F/°C button on the back of the Digital Atomic 

Clock to switch the temperature display from Fahrenheit to Celsius. 

 

Flashing Outdoor Temperature 

 

  The outdoor Temperature reading will flash when the connection is first lost or intermittent 

between the Digital Atomic Clock and the outdoor transmitter.   

 

Distance/Resistance

 is generally the cause of intermittent connection or loss of connection 

between the transmitter and the Digital Atomic Clock.  

  Check the 

position

 of the Digital Atomic Clock. Turn the Digital Atomic Clock 90 degrees 

towards the outdoor transmitter for better reception.  

  Try the 

quick connect

 or 

factory restart

. 

 

Batteries

 often resolve the connection issue. 

 

Dashes shown for Outdoor Temperature 

 

  Dashes means the connection is lost between the Digital Atomic Clock and the outdoor 

transmitter.   

 

Batteries

 often resolve the connection. 

 

Distance/Resistance

 can cause loss of connection between the transmitter and the Digital 

Atomic Clock.  

  Reorientation of the Digital Atomic Clock 90 degrees towards the outdoor transmitter may 

provide better reception.  

  Try the 

quick connect

 or 

factory restart

. 

 

Quick Connect 

 

Explanation:

 The quick connect is used for a clock and outdoor sensor that have been working but lost 

connection due to interference or low batteries. This is not a thorough factory reset. 
 
1. 

Bring the outdoor sensor and clock together inside and place the units 5-10 feet apart with nothing 
between them.  

2. 

Hold the 

+

 button on the wireless thermometer. The outdoor temperature area will flash. 

3. 

Remove battery cover from the outdoor sensor and press and release the TX button to send the 
signal. 

4. 

Wait for 2 minutes for the outdoor temperature to appear on the clock. 

 

 

 

Factory Restart

:  If the above procedure does not work, please try the factory reset below. 

 

Содержание 513-149V2

Страница 1: ... Constantly 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is Stuck or OFL 4 Outdoor Transmitter Fell and No Longer Works 4 Outdoor Transmitter Drains Batteries Quickly 5 Temperature Trend Arrows 5 Mounting Positioning Outdoor Transmitter 5 Position Digital Atomic Clock 6 Distance Resistance Interference 6 Accuracy 7 Indoor Temperature 7 Outdoor T...

Страница 2: ...ronment the batteries reside in for the 10 years can deplete the power Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment A minimum voltage of 1 48V for each battery is necessary for proper performance Outdoor Transmitters Use Alkaline batteries or Lithium for temperatures below 20 F 28 8 C Indoor Displays Use Alkaline...

Страница 3: ...n between the transmitter and the Digital Atomic Clock Check the position of the Digital Atomic Clock Turn the Digital Atomic Clock 90 degrees towards the outdoor transmitter for better reception Try the quick connect or factory restart Batteries often resolve the connection issue Dashes shown for Outdoor Temperature Dashes means the connection is lost between the Digital Atomic Clock and the outd...

Страница 4: ...wn Move the outdoor transmitter to a closer location Freezer test Confirm the Digital Atomic Clock is reading the correct outdoor transmitter Place the transmitter in the freezer for an hour and watch the temperature drop on the Digital Atomic Clock Indoor distance test Please complete the Restart with transmitter and Digital Atomic Clock 5 10 feet apart and inside to establish a strong connection...

Страница 5: ...flect the temperature change in the past three hours UP ARROW Temperature rising more than 2 F 1 C over the past three hours RIGHT ARROW Temperature did not change more than 2 F 1 C over the past three hours DOWN ARROW Temperature falling more than 2 F 1 C over the past three hours Mounting Positioning Outdoor Transmitter Mount outdoor Temperature transmitters vertically and under a bit of an over...

Страница 6: ... mounting screws not included into a wall within transmission range of the outdoor transmitter leaving approximately 3 16 of an inch 5mm extended from the wall Place the Digital Atomic Clock onto the screws using the hanging holes on the backside Gently pull the Digital Atomic Clock down to lock the screws into place Note Always ensure that the Digital Atomic Clock locks onto the screws before rel...

Страница 7: ...ct temperature as long as the LCD display continues to function Temperature Cycle 30 seconds Outdoor Temperature Measure range 40 to 158 0 to 70 Accuracy 1 degree Fahrenheit at room temperature 68F to 75F 20 to 24 Accuracy 2 degrees Fahrenheit 32 F to 122 F 0 to 50 Accuracy 4 degrees Fahrenheit otherwise Resolution 0 1 degree F Digital Atomic Clock How tall are the Time Numbers The time numbers ar...

Страница 8: ...he past 24 hours Reposition the Digital Atomic Clock with the front or back facing Colorado Check that the Time Zone selected correctly reflects your location Adjust the time zone in the Program Menu Check that the DST indicator is correct for your location most areas observe DST so this should be ON Adjust the DST indicator in the Program Menu Large buildings metal roofed buildings and buildings ...

Страница 9: ...is activated DEACTIVATE From the time mode press and release the ALARM button once to show Alarm Time With the Alarm time showing press and release the ALARM button to deactivate the alarm The alarm icon will disappear when alarm is deactivated Snooze Alarm When the alarm sounds press the SNOOZE button to trigger snooze alarm for 9 minutes The snooze icon Zz will flash when the snooze feature is a...

Страница 10: ...e weekday will set automatically after the year month and date are set FAHRENHEIT CELSIUS Press and release the F C button to select temperature readings in Fahrenheit or Celsius No WWVB Tower Icon The Digital Atomic Clock has not received a WWVB time signal in the past 24 hours Position the Digital Atomic Clock for better reception Hold the TIME button to send the Digital Atomic Clock on a signal...

Страница 11: ... displays This can make the Digital Atomic Clock display appear frozen With all power removed the Digital Atomic Clock should be blank If numbers still appear please check for scratch guard Check that the batteries are installed correctly This is generally a power related issue Batteries may be overpowered or underpowered Remove batteries from Digital Atomic Clock Press any button 20 times Leave t...

Отзывы: