background image

6 | 

P a g e

 

 

 

 

 

Add-on Sensor: 

1. Install batteries Temperature & Humidity sensor.  

2. Hold the + (PLUS) button until the Reception Indicator        starts to animate. This will 

start a search for your sensor. Press the TX button on the sensor. 

3. Your sensor should connect within the next few minutes.  

 

View Add-on Sensor: 

 

Press the   button to view Add-on Sensor readings, Time, Desired Time, or Indoor 

Temperature & Humidity. 

WHAT DOES A READING OF “HI” OR “LO” MEAN? 

 

 

If your outdoor temperature reading shows “HI” or “LO”, check that your 

batteries

 are 

good. 

 

Overpowered or underpowered batteries can cause this reading. 

 

If batteries are good, replace the outdoor sensor. 

 

If your temperature is fine but your humidity is reading “HI” or “LO” or dashes, your 

humidity may be below 10% Relative Humidity.  Your sensor does not read below 10% 

humidity. 

WHAT DOES “

NO

” MEAN? 

 

 

If a sensor loses connection to the clock for any reason, the clock will show 

NO

 after 30 

minutes. 

 

The clock will search for 3 minutes every hour to reconnect with sensor. 

 

Hold the

 + (PLUS)

 button to search for the sensors in the Outdoor Area 

 

Icon will flash while searching for sensor. Outdoor area will show dashes during 

the search. When sensor is received the icon will be solid. 

 

If no sensor received, icon disappears after 3 minutes of searching if sensor is 

not found.  

 

NO

 will again show in the outdoor sensor area.  

 

FACTORY RESET: HOW DO I FACTORY RESET MY CLOCK? 

 

To factory reset your clock: 

1.

 

Remove batteries and press any button 20 times. 

2.

 

Reinsert batteries. 

Отзывы: