background image

308-1414B / 308-1414W      www.lacrossetechnology.com/support       

Page | 3

  

Press and release the 

TIME SET

 button to exit, or wait 20 seconds 

without pressing buttons to return to the time display. 

 

SET TEMPERATURE ALERTS 

 

1.  Hold the 

ALERTS 

button for 3 seconds.

 

 

2.  The temperature alert value will blink in set mode. 
3.  Press and release 

the ▼ or ▲ buttons to adjust alert values. 

4.  Press and release the 

ALERTS

 button to confirm & move to the next 

alert. 

 

The temperature alert order:

  

1.

 Outdoor High 

2.

 Outdoor Low 

3.

 Indoor High 

4.

 Indoor Low  

 

Press and release the 

ALERTS

 button to exit, or wait 20 seconds without 

pressing buttons to return to normal time display 

 

ARM / DISARM TEMPERATURE ALERTS 

 

Press and release the 

ALERTS

 button to toggle between the alerts 

Outdoor HI / Outdoor LOW / Indoor HI / Indoor LOW 

  

 

Arm the alert with 

the ▲button. 

 

Disarm the alert with 

the ▼ button. 

 

ALERT BELL ICON appears when armed. 

 

 

                   

 

  

 

ACTIVE TEMPERATURE ALERT 

 

 

Beeps once per minute with flashing alert bell icon. 

 

Press any button to stop the alert.  

 

SET TIME ALARM 

 

1.  Hold the 

ALARM

 button to enter alarm time set mode.  

2.  Press 

the ▼ or ▲ buttons to adjust alarm time.  

3.  Press the 

ALARM

 button to confirm adjustments and move to the 

next item. 

 

Alarm Time setting order:

 

1.

 Hours 

2.

 Minutes 

 
 

Содержание 308-1414B

Страница 1: ...er Manual of Product 1 La Crosse Technology 308 1414B INT Wireless Atomic Digital Color Forecast Station with Alerts Black User Manual of Product 2 La Crosse Technology C85845 INT Weather Station Blac...

Страница 2: ...ruction Manual DC 020816 WIRELESS COLOR WEATHER STATION Time Calendar Sensor Battery Cover Sensor Battery Compartment 2 AA SENSOR TX141TH BV2 LED TX FRONT VIEW Outdoor Temp Trends Outdoor Humidity Tre...

Страница 3: ...ash when transmitting 4 After 5 minutes place sensor in a shaded outdoor location SET TIME DATE AND TEMPERATURE UNITS Note Only press or hold one button at a time 1 Hold the TIME SET button 3 seconds...

Страница 4: ...r Low Press and release the ALERTS button to exit or wait 20 seconds without pressing buttons to return to normal time display ARM DISARM TEMPERATURE ALERTS Press and release the ALERTS button to togg...

Страница 5: ...n Zz will flash In snooze mode press any button to stop the alarm for one day Note The alarm is crescendo sound The alarm will sound for 2 minutes and then shut off completely FORECAST ICONS The weath...

Страница 6: ...e button for 5 seconds to reset minimum values Press and release the button to view maximum values Hold the button for 5 seconds to reset maximum values SEARCH FOR OUTDOOR SENSOR Hold the HEAT DEW but...

Страница 7: ...20 F 28 8 C require Lithium batteries in the outdoor sensor Humidity Range 10 99 RH Distance Over 300 ft 91 meters RF 433MHz open air Power Weather Station Primary Power AC 6 Number 5 volt AC power a...

Страница 8: ...the battery contacts and also those of the device prior to battery installation Ensure the batteries are installed correctly with regard to polarity and Remove batteries from equipment when it not to...

Страница 9: ...adio TV technician for help This device must not be co located or operating in conjunction with any other antenna or transmitter Operation is subject to the following two conditions 1 This device may...

Страница 10: ...Wireless Color Weather Station INSTRUCTION MANUAL MODEL C85845V4 DC 071620 FIND MANUALS FAQS AND MORE UNDER THE SUPPORT TAB HERE bit ly laxtech_support...

Страница 11: ...mperature Humidity Alerts 8 Arm Disarm Alerts 9 HI LO Temperature Humidity Records 9 Heat Index and Dew Point Explained 10 Temperature Humidity Trend Arrows 10 Sensor Search 10 Forecast Icons 11 Low B...

Страница 12: ...Once the Outdoor Sensor is reading to your station place it outside in a shaded location Watch sensor mounting video http bit ly TH_SensorMounting Outdoor Sensor TX141TH Bv3 Wireless Weather Station...

Страница 13: ...M PM Atomic Time Alarm Snooze Weekday Month Date 8 Atomic Reception 2 3 4 1 5 6 7 8 2 3 4 1 5 6 7 Alerts HI LO OFF Temperature Trend Outdoor Temperature Low Battery Sensor Strength Outdoor Humidity Hu...

Страница 14: ...at UTC 7 00 8 00 9 00 10 00 and 11 00 If there is no WWVB reception the station will search for the Atomic Time Signal every 2 hours until the WWVB Time is received The Atomic Time Signal Icon will fl...

Страница 15: ...e 7 Press SET to select 12 24 hour time format 12H will show Press the or button if you prefer 24 hour time format 8 Press SET to select Hours The Hour will show Press the or button to adjust the hour...

Страница 16: ...the alert value will flash Press the or buttons to change the alert value 3 Press the ALERTS button to confirm and move to the next alert Note If you do not wish to set an alert press the ALERTS butto...

Страница 17: ...Humidity ON OFF Outdoor HIGH Humidity Value Outdoor LOW Humidity ON OFF Outdoor LOW Humidity Value Indoor HIGH Temperature ON OFF Indoor HIGH Temperature Value Indoor LOW Temperature ON OFF Indoor LO...

Страница 18: ...mperature Humidity Station Page 9 HEAT INDEX DEW POINT EXPLAINED Heat Index Heat Index combines the effects of heat and humidity It is the apparent temperature of how hot it feels to a human being As...

Страница 19: ...batteries Hold the TEMP button for 3 seconds to search for the sensor Sensor Reception icon will flash while searching and be solid when sensor signal is received If you regain connection while the se...

Страница 20: ...is blank before proceeding there may be lines painted on the screen that will show when there is no power 4 Leave both units without power for 15 minutes very important 5 Insert the AC power cord into...

Страница 21: ...8am 6pm CST JOIN THE CONVERSATION Ask questions watch detailed setup videos and provide feedback on our social media outlets Wireless Temperature Humidity Station Page 12 CARE AND MAINTENANCE Do not m...

Страница 22: ...his equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However the...

Страница 23: ...booklet may contain errors or misprints The information it contains is regularly checked and corrections are included in subsequent editions We disclaim any responsibility for any technical error or p...

Отзывы: