![La Cornue CornuFe Скачать руководство пользователя страница 32](http://html2.mh-extra.com/html/la-cornue/cornufe/cornufe_service-instructions-manual_3104995032.webp)
32
SERVICING WARNING WORK SAFELY
Where necessary disconnect from electricity and gas before starting.
Check range is safe when you have finished.
Technical Data
This range is supplied set for Natural gas.
A conversion kit from Natural Gas to Propane gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION: Inside base of drawer cavity - remove drawer. For removal of drawer see installation
instructions.
Country of Destination: USA/Canada
Gas
Electric
Natural Gas
4.0” W.C (10 mbar)
240V 60Hz
Propane
10.0” W.C (25 mbar)
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 35 13/16” (91 cm)
maximum 36 7/8” (93.7 cm)
Overall width
43” (109.2cm) See ‘Positioning the Range’
Overall depth
28 5/8” (72 .5cm).
Space for fi xing
See ‘Positioning the Range’
Minimum space above cooktop
31.5” (80cm)
Connections
Gas :
Electric:
½” NPT at rear right-hand side
240 V 60 Hz
Ratings
Cooktop
Natural Gas
Propane Gas
Input
Orifice
Screw
Input
Orifice
Screw
Center burner
17,500 Btu/hr
205
82
17,500 Btu/hr
118
49
Large Burners
12,000 Btu/hr
150
70
12,000 Btu/hr
99
38
Right hand front Burner
6,000 Btu/hr
112
53
6,000 Btu/hr
68
31
Gas burner inputs based on Gross Calorifi c Value